Un método sencillo para ayudar a la comprobación del correcto posicionamiento de los tubos endotraqueales de doble luz izquierdos
Correct placement of left-sided double lumen endotracheal tubes: a simple verification technique
Visitas
1493
B. Aznárez Zango
,
Autor para correspondencia
baznarez@yahoo.es

Corespondencia: Servicio de Anestesia y Reanimación. Hospital Universitario de la Princesa. C/ Diego de León n° 62. 28006 Madrid.
, S. Postigo Morales**, M. García Raimundo***, J.L. Jover Pinillos****, A. Maruenda Paulino***, J. Belda Nácher***
* Servicio de Anestesia y Reanimación. Hospital Universitario de la Princesa. Madrid
** Servicio de Anestesia y Reanimación. Hospital de Galdácano.Vizcaya
*** Servicio de Anestesia y Reanimación. Hospital Clínico Universitario. Valencia
**** Servicio de Anestesia y Reanimación. Hospital Verge dels Lliris. Alcoy. Alicante
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (1)
Tabla 1. Tabla de resultados
Resumen
Objetivo

Los tubos endobronquiales de doble luz (TDL) se utilizan en cirugía torácica para la intubación selectiva pulmonar, necesaria para la ventilación unipulmonar. La comprobación de su correcta colocación se realiza mediante fibrobroncoscopia. Presentamos un método simple y alternativo para ayudar a la comprobación del posicionamiento de los TDL izquierdos, que consiste en pasar una sonda de aspiración por la rama traqueal del TDL. Nuestra hipótesis es que si la sonda pasa sin dificultad el tubo estaría colocado correctamente. El objetivo de este estudio fue la determinación de la sensibilidad y especificidad de la prueba.

Material y método

Pacientes programados para cirugía torácica electiva de neumonectomía o lobectomía izquierdas. Tras pasar la sonda por el TDL izquierdo se comprobó con el fibrobroncoscopio (técnica de referencia), comparándose ambos métodos.

Resultado

Se incluyeron 100 pacientes. De los casos estudiados, en el 88% se dedujo una correcta posición del TDL por paso de sonda sin resistencia. De estos, en el 84% la fibrobroncoscopia corroboró esta situación mientras que en el 4% restante no fue así y hubo que recolocarlos. En el 12% se encontró resistencia al pasar la sonda verificándose en éstos una mala colocación por fibrobroncoscopio.

Conclusiones

Si dominamos esta técnica o si no disponemos de fibrobroncoscopio, esta maniobra puede ser útil y de mucha ayuda durante la colocación de los TDL izquierdos. Nuestros resultados apoyan la práctica cotidiana de esta maniobra, ya que es un método sencillo y accesible, pero recordando que la comprobación mediante fibrobroncoscopio es la técnica de referencia actualmente.

Palabras clave:
Intubación selectiva
Tubo endotraqueal de doble luz
Fibrobroncoscopia
Sonda estándar de aspiración de 12 ch
Summary
Objetive

Double lumen endotracheal tubes (DLTs) are used in thoracic surgery for selective bronchial intubation, which is required for single lung ventilation. Correct placement of the tube is checked by means of fiberoptic bronchoscopy. We present a simple alternative method to help confirm the correct placement of left-sided DLTs. The method consists of passing a suction catheter through the tracheal lumen of the tube. Our hypothesis was that if the catheter can be inserted without difficulty, the tube is correctly placed. The objective was to determine the sensitivity and specificity of that criterion.

Material and methods

We studied patients scheduled for elective left pneumonectomy or lobectomy. After passing the catheter through the left-sided DLT, placement was checked by means of fiberoptic bronchoscopy (gold standard) and the results were compared with the placement assessment based on ease of insertion.

Results

One hundred patients were included. The DLT was judged to be correctly placed in 88% of patients in whom the catheter was inserted without resistance. Bronchoscopy corroborated this finding in 84% of cases; the tube was found to be incorrectly placed in the remaining 4% of cases and had to be reinserted. Resistance was noted in 12% of cases and bronchoscopy confirmed that the tube was incorrectly placed in those patients.

Conclusions

This technique can be very useful in placing left-sided DLTs in situations where fiberoptic bronchoscopy is not available and if the anesthesiologist has a thorough command of the method. Our results support the routine use of this criterion as it is simple and easy to learn. It should be remembered, however, that confirmation of placement by means of fiberoptic bronchoscopy is currently the gold standard technique.

Key words:
Selective intubation
Double lumen endotracheal tube
Fiberoptic
bronchoscopy
Standard 12F suction catheter

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Anestesiología y Reanimación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Anestesiología y Reanimación

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.redar.2022.03.001
No mostrar más