CASO CLÍNICO
DOI: 10.1016/j.redar.2015.07.002
Fluidoterapia intraoperatoria en lactante con insuficiencia cardiaca congestiva por fístula arteriovenosa pial intracraneal
Intraoperative fluid therapy in infants with congestive heart failure due to intracranial pial arteriovenous fistula
Visitas
395
F.J. Arroyo-Fernándeza,
Autor para correspondencia
fcoarronimo@icloud.com

Autor para correspondencia.
, E. Calderón-Seoanea, F. Rodríguez-Peñab, L.M. Torres-Moreraa
a Servicio de Anestesiología, Reanimación y Tratamiento del Dolor, Hospital Universitario Puerta del Mar, Cádiz, España
b Servicio de Neurocirugía, Hospital Universitario Puerta del Mar, Cádiz, España
Este artículo ha recibido
395
Visitas
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Resumen

La fístula arteriovenosa pial es una malformación congénita intracraneal infrecuente (0,1-1:100.000 habitantes). Presenta un alto flujo sanguíneo entre una o más arterias piales y un drenaje en la circulación venosa. Suele diagnosticarse durante la edad pediátrica al desencadenar un cuadro de hipertensión intracraneal y/o una insuficiencia cardiaca congestiva por shunt sistémico izquierda-derecha. Al ser poco frecuente y tener una fisiopatología compleja, su manejo perioperatorio anestésico no está bien establecido.

Presentamos el caso de un lactante de 6 meses con fístula arteriovenosa pial con hipertensión intracraneal e insuficiencia cardiaca congestiva por shunt izquierda-derecha, que se sometió a craneotomía y pinzamiento de la malformación vascular. Las consideraciones anestésicas en pacientes con esta afección suponen un importante reto y deben realizarse por equipos multidisciplinares con experiencia en pediatría. Especial interés ocupa el manejo de la volemia durante el curso intraoperatorio, por exceso, para no precipitar una insuficiencia cardiaca congestiva o una hipertensión intracraneal, y por defecto, una hipoxia tisular por el sangrado.

Palabras clave:
Fístula arteriovenosa pial
Pediátrica
Neuroanestesia
Insuficiencia cardiaca congestiva
Abstract

Pial arteriovenous fistula is a rare intracranial congenital malformation (0.1-1: 100,000). It has a high blood flow between one or more pial arteries and drains into the venous circulation. It is usually diagnosed during the childhood by triggering an intracranial hypertension and/or congestive heart failure due to left-right systemic shunt. It is a rare malformation with a complex pathophysiology. The perioperative anaesthetic management is not well established.

We present a 6-month-old infant diagnosed with pial arteriovenous fistula with hypertension and congestive heart failure due to left-right shunt. He required a craniotomy and clipping of vascular malformation. Anaesthetic considerations in patients with this condition are a great challenge. It must be performed by multidisciplinary teams with experience in paediatrics. The maintenance of blood volume during the intraoperative course is very important. Excessive fluid therapy can precipitate a congestive heart failure or intracranial hypertension, and a lower fluid therapy may cause a tissue hypoxia due to the bleeding.

Keywords:
Pial arteriovenous fistula
Paediatric
Neuroanaesthesia
Congestive heart failure

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Anestesiología y Reanimación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Anestesiología y Reanimación

Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

es en pt
Política de cookies Cookies policy Política de cookies
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.