Buscar en
Rehabilitación
Toda la web
Inicio Rehabilitación Valoración de la exactitud de la infiltración de toxina botulínica a ciegas e...
Información de la revista
Vol. 45. Núm. 2.
Páginas 112-116 (Abril - Junio 2011)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
3842
Vol. 45. Núm. 2.
Páginas 112-116 (Abril - Junio 2011)
Original
Valoración de la exactitud de la infiltración de toxina botulínica a ciegas en niños y adolescentes con parálisis cerebral
Blinded evaluation of the accuracy of botulinum toxin in children and adolescents with cerebral palsy
Visitas
3842
M. Rodríguez Piñero-Durán
Autor para correspondencia
mrpd@telefonica.net

Autor para correspondencia.
, C.M. Mesa López, L. Gómez Linares, M.E. Martínez-Sahuquillo Amuedo, C. Echevarría Ruiz De Vargas
Hospital Universitario Virgen del Rocío, Sevilla, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (2)
Tabla 1. Patrones espásticos tratados
Tabla 2. Músculos infiltrados con porcentaje de aciertos en su punción
Mostrar másMostrar menos
Resumen
Objetivos

Evaluar la exactitud de la infiltración manual frente a la guiada con electroestimulación de los músculos distales o profundos de las extremidades.

Material y método

Estudio prospectivo en el que se infiltran 289 músculos en 29 pacientes afectos de parálisis cerebral con edades comprendidas entre 1 y 19 años, comparándose la exactitud de la infiltración guiada por referencias anatómicas asociada a la reproducción del movimiento muscular frente a aquella realizada mediante guía con electroestimulación.

Resultados

Se muestran los distintos patrones de espasticidad tratados y los porcentajes de aciertos obtenidos en cada músculo al realizar infiltración guiada mediante referencias anatómicas. Existe un porcentaje de aciertos inferior al 50% en 10 de los 16 músculos infiltrados.

Conclusiones

La infiltración de los músculos pequeños, profundos y distales precisa de una guía instrumentada, de las cuales la electroestimulación es asequible y certera.

Palabras clave:
Toxina botulínica tipo A
Electroestimulación
Precisión
Abstract
Objective

To evaluate the accuracy of manual infilitration versus electrostimulation-guided of the distal or deep muscles of the limbs.

Material and method

A prospective study was carried out in which 289 muscles were injected in 29 patients who had cerebral palsy (aged 1 to 19years). The accuracy of manual puncturing following anatomical references associated to the reproduction of muscle movement was compared to that guided by electrostimulation.

Results

The spasticity patterns treated as well as the percentages of successful injections guided for anatomical reference for each muscle are shown. The percentage of successful injections was <50% in 10 out of the 16 muscles injected.

Conclusions

To inject small, deep and distal muscles, an instrumental guide such as electrostimulation, which is both easily available and accurate, is required.

Keywords:
Botulinum toxin type A
Electroestimulation
Accuracy

Artículo

Opciones para acceder a los textos completos de la publicación Rehabilitación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Rehabilitación

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.rh.2019.07.004
No mostrar más