metricas
covid
Buscar en
Cirugía Española (English Edition)
Toda la web
Inicio Cirugía Española (English Edition) Refractory hypoxemia in critical trauma patient. Usefulness of extra-corporeal m...
Journal Information
Vol. 99. Issue 9.
Pages 690-692 (November 2021)
Vol. 99. Issue 9.
Pages 690-692 (November 2021)
Scientific letter
Full text access
Refractory hypoxemia in critical trauma patient. Usefulness of extra-corporeal membrane oxygenation
Hipoxemia refractaria en la enfermedad traumática grave. Utilidad de la ECMO veno-venosa
Visits
471
María A. Ballesterosa,
Corresponding author
gelesballesteros@yahoo.com

Corresponding author.
, Borja Suberviola Cañasa, María Juncal Sánchez Arguianoa, Laura Sánchez-Morenob, Eduardo Miñambresa,c
a Servicio de Medicina Intensiva, Hospital Universitario «Marqués de Valdecilla»-IDIVAL, Santander, Spain
b Servicio de Cirugía Torácica, Hospital Universitario «Marqués de Valdecilla»-IDIVAL, Santander, Spain
c Facultad de Medicina, Universidad de Cantabria, Santander, Spain
This item has received
Article information
Full Text
Bibliography
Download PDF
Statistics
Figures (2)
Full Text

The use of veno-venous extracorporeal membrane oxygenation devices (VV-ECMO) in severe respiratory failure due to trauma has been controversial and is not completely defined, which is probably due to its underuse in this population. VV-ECMO provides adequate oxygenation until the lungs recover. However, one limiting factor for its generalized use has been the risk of bleeding due to both the trauma as well as the anticoagulation necessary to use this system1. In this article, we describe a case of trauma-related refractory hypoxemia treated with ECMO without using anticoagulation, which demonstrates that these devices can be considered a rescue measure once previous therapeutic options have been optimized.

We present the case of a 65-year-old woman who had been hit by a car. Upon admission to the Intensive Medicine Unit, she was conscious and showed no focal lesions; BP 90/60, HR 90 bpm, tachypnea ​​RR 20, SatO2 90%. Physical examination revealed a hematoma on the left cheekbone, hypoventilation in the base of the right lung, slight abdominal guarding, and pelvic pain on palpation. An imaging study showed a fracture of two unifocal right ribs with bilateral pulmonary contusion (Fig. 1A), lacerated liver, spinal trauma (fracture of five right transverse processes from T12 to L4) and skeletal trauma (fractures in both sacra alae, communicated fracture of the left pubis with fractures of both pubic branches, and right anterior acetabular rim). No intracranial injuries were observed.

Fig. 1.

A) Computed tomography (CT) scan upon admission to the Intensive Care Unit; B) CT scan 16 h after admission, coinciding with severe hypoxemia.

(0.12MB).

During the first few hours of treatment, the patient presented hemorrhagic shock, requiring blood products and vasoactive drugs (massive bleeding protocol was activated). Orotracheal intubation was performed, and the study was completed with arteriography. Several foci of contrast extravasation were identified, suggestive of bleeding from the left hypogastric and epigastric arteries. These were embolized, and hemodynamic stability was achieved.

At the same time, the respiratory failure was worsening. PaO2/FiO2 was 65 and PEEP 15. Sedation was maintained with midazolam and fentanyl, with the occasional addition of cisatracurium to optimize ventilatory function. The imaging test was repeated 16 h after admission to the ICU, which demonstrated progression of the pulmonary contusions (Fig. 1B). The transthoracic echocardiogram study did not reveal alterations. We then decided to establish femoral-jugular VV-ECMO (CardioHelp®, Maquet Holding, Germany) (Fig. 2). The placement of the cannulae was guided by transesophageal echocardiogram. Heparin was prescribed during implantation itself, using a flow rate of 3 bpm, and anticoagulation was reversed with protamine (80 mg) one hour later. We decided to reverse anticoagulation due to the risk of hemorrhage secondary to the liver injury, pelvic fractures, hematoma in the psoas and coagulopathy secondary to the massive hemorrhage over the previous hours. Mechanical ventilation was precautionary with PEEP 12 cm H2O and TV 4 mL/kg, FiO2 45%. After implantation, a bronchoscopy study showed no lesions or bloody secretions. With the therapy established, we observed improved oxygenation (PO2 measured in the left radial artery), hemodynamics and serum lactate; diuresis was preserved, and a negative fluid balance was finally reached. On the 3rd day, weaning from ECMO was initiated after the improved radiology and arterial blood gas results. We reduced the ECMO oxygen flow, ventilating with FiO2 < 45% and PEEP < 10 cm H2O, and PaO2/FiO2 > 200 was observed. Therefore, VV-ECMO was withdrawn on the 4th day. No device-related complications were detected during ECMO treatment. A tracheostomy was performed on the 7th day due to the need for respiratory support due to polyneuropathy. Finally, the patient was transferred to the hospital ward.

Fig. 2.

Diagram of the VV-ECMO device used. VV-ECMO: veno-venous extracorporeal membrane oxygenation; PEEP: positive end-expiratory pressure; RR: respiratory rate.

(0.17MB).

Respiratory failure after severe trauma may be due to a trauma-related lung injury itself, but it also may be indirectly caused by massive transfusion, bronchial aspiration, or fat embolism. VV-ECMO systems make it possible to ensure correct oxygenation to the tissues while the lungs are recovering from the damage that caused severe respiratory failure. Its use could be considered due to the persistence of severe hypoxemia (PaO2/FiO2 < 120 with FiO2 > 90% and PEEP > 10) after optimization of less invasive therapeutic measures (lung-protective ventilation)2,3.

ECMO machines are used in critical care units both in situations of cardiorespiratory compromise and in asystole donation processes4. However, the accumulated experience in severe trauma has been limited to case series5,6, probably due to the hemorrhagic risk involved3. This risk is present at the time of cannulation and facilitated by trauma-related coagulopathy, as well as by the anticoagulation entailed in the use of these systems. The need for anticoagulation and dosage for VV-ECMO machines must be individualized, and the risk–benefit ratio should be assessed for each patient. The decision to rule out the use of anticoagulation or to lower the dosage requires close monitoring of the flows through the device, and neither is an absolute limitation. In our case, we dismissed heparinization due to the high risk of bleeding given the patient’s liver and pelvic injuries. In severe trauma, initial heparin administration has been reported to be associated with increased hemorrhagic complications. However, in our case, there was no incidence of this type, perhaps because we reversed the initial heparin.

Another point of debate is when to establish these therapies. The case described, in which VV-ECMO was initiated 12 h after admission and was maintained for a period of 80 h, supports the implementation of these machines early as they have been associated with better results and lower mortality7,8. In fact, in the trauma patient population, mortality associated with the use of ECMO has occurred predominantly in cases with delayed use and when veno-arterial ECMO was required due to circulatory failure, while the early initiation of VV-ECMO due to respiratory dysfunction had better results9. We believe that early initiation can contribute towards faster lung recovery, while avoiding the potential adverse effects associated with these systems. Initial results seem to show survival rates similar to those of non-trauma patients and make this support a promising therapeutic option for these highly complex patients10.

After the optimization of other therapeutic options, VV-ECMO systems can be considered a rescue therapy against refractory hypoxemia in patients with severe trauma. Patient selection and early initiation are two key elements that should be addressed individually in each case. The hemorrhagic risk must be evaluated since it alone is not a contraindication.

Conflict of interests

The authors have no conflict of interests to declare.

References
[1]
V. Della Torre, C. Robba, P. Pelosi, F. Bilotta.
Extra corporeal membrane oxygenation in the critical trauma patient.
Curr Opin Anaesthesiol., 32 (2019), pp. 234-241
[2]
V. Della Torre, R. Badenes, F. Corradi, F. Racca, A. Lavinio, B. Matta, et al.
Acute respiratory distress syndrome in traumatic brain injury: how do we manage it.
J Thorac Dis., 9 (2017), pp. 5368-5381
[3]
D. Zonies, M. Merkel.
Advanced extracorporeal therapy in trauma.
Curr Opin Crit Care., 22 (2016), pp. 578-583
[4]
E. Miñambres, P. Ruiz, M.A. Ballesteros, C. Álvarez, J.M. Cifrián, A. Lander, et al.
Combined lung and liver procurement in controlled donation after circulatory death using normothermic abdominal perfusion. Initial experience in two Spanish centers.
Am J Transplant., 20 (2020), pp. 231-240
[5]
C.R. Burke, A. Crown, T. Chan, D.M. McMullan.
Extracorporeal life support is safe in trauma patients.
Injury., 48 (2017), pp. 121-126
[6]
J. Swol, D. Brodie, L. Napolitano, P.K. Park, R. Thiagarajan, R.P. Barbaro, et al.
Indications and outcomes of extracorporeal life support in trauma patients.
J Trauma Acute Care Surg., 84 (2018), pp. 831-837
[7]
P.L. Bosarge, L.A. Raff, G. McGwin Jr, S.L. Carroll, S.C. Bellot, E. Diaz-Guzman, et al.
Early initiation of extracorporeal membrane oxygenation improves survival in adult trauma patients with severe adult respiratory distress syndrome.
Trauma Acute Care Surg., 81 (2016), pp. 236-243
[8]
J.A. Watson, B.R. Englum, J. Kim, O.O. Adibe, H.E. Rice, M.L. Shapiro, et al.
Extracorporeal life support use in pediatric trauma: a review of the National Trauma Data Bank.
J Pediatr Surg., 52 (2017), pp. 136-139
[9]
C. Robba, A. Ortu, F. Bilotta, A. Lombardo, M.S. Sekhon, F. Gallo, B.F. Matta.
Extracorporeal membrane oxygenation for adult respiratory distress syndrome in trauma patients: a case series and systematic literature review.
J Trauma Acute Care Surg., 82 (2017), pp. 165-173
[10]
C. Ull, T.A. Schildhauer, J.T. Strauch, J. Swol.
Outcome measures of extracorporeal life support (ECLS) in trauma patients versus patients without trauma: a 7-year single-center retrospective cohort study.
J Artif Organs., 20 (2017), pp. 117-124

Please cite this article as: Ballesteros MA, Suberviola Cañas B, Sánchez Arguiano MJ, Sánchez-Moreno L, Miñambres E. Hipoxemia refractaria en la enfermedad traumática grave. Utilidad de la ECMO veno-venosa. Cir Esp. 2021;99:691–693.

Copyright © 2020. AEC
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos