metricas
Revista Española de Anestesiología y Reanimación Plexus and peripheral nerve block anaesthesia – A step beyond ultrasound or fu...
Información de la revista
Vol. 63. Núm. 3.
Páginas 129-188 (Marzo 2016)
Cita
Cita
Compartir
Descargar PDF
Más opciones de artículo
Vol. 63. Núm. 3.
Páginas 129-188 (Marzo 2016)
Editorial article

Plexus and peripheral nerve block anaesthesia – A step beyond ultrasound or full circle?

Anestesia con bloqueo nervioso periférico y del plexo: ¿Un paso más allá de la ecografía o el cierre del círculo?
Visitas
1799
A. Krola,
Autor para correspondencia
andrzej.krol@stgeorges.nhs.uk

Corresponding author.
, J. De Andresb
a Department of Anaesthesia and Chronic Pain Service, St Georges University Hospitals, London, UK
b Department of Anaesthesia, Critical Care and Pain Management, University of Valencia, School of Medicine, General University Hospital, Valencia, Spain
Este artículo ha recibido
Información del artículo
Texto completo
Bibliografía
Descargar PDF
Estadísticas

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Anestesiología y Reanimación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
References
[1]
S. Kapral, P. Krafft, K. Eibenberger, R. Fitzgerald, M. Gosch, C. Weinstabl.
Ultrasound guided supraclavicular approach for regional anesthesia of the brachial plexus.
Anesth Analg, 78 (1994), pp. 507-513
[2]
S. Kapral, P. Krafft, M. Gosch, D. Fleishmann, C. Weinstabl.
Ultrasound imaging for stellate ganglion block. Direct visualization of puncture site and local anaesthetic spread.
Reg Anesth, 20 (1995), pp. 323-328
[3]
www.ncbi.nlm.nih.gov/pubmed/ [accessed on 13.10.15].
[4]
G.C.S. Smith, J.P. Pell.
Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomised controlled trials.
Br Med J, 327 (2003), pp. 1459-1461
[5]
M.S. Abrahams, M.F. Aziz, R.F. Fu, J.L. Horn.
Ultrasound guidance compared with electrical neurostimulation for peripheral nerve block: a systematic review and meta-analysis of randomized controlled trials.
Br J Anaesth, 102 (2009), pp. 408-417
[6]
S.S. Liu, J.E. Ngeow, J.T. Yadeau.
Ultrasound-guided regional anesthesia and analgesia: a qualitative systematic review.
Reg Anesth Pain Med, 34 (2009), pp. 47-59
[7]
J.M. Neal.
Ultrasound-guided regional anesthesia and patient safety: an evidence-based analysis.
Reg Anesth Pain Med, 35 (2010), pp. S59-S67
[8]
Y. Auroy, P. Narchi, A. Messiah, L. Litt, B. Rouvier, K. Samii.
Serious complications related to regional anesthesia: results of a prospective survey in France.
Anesthesiology, 87 (1997), pp. 479-486
[9]
S.L. Kopp, M.J. Hargett, G.A. Liguori, J.M. Neal, L. Le-Wendling, E.G. Votta-Velis, et al.
Guidelines for fellowship training in regional anesthesiology and acute pain medicine: third edition, 2014.
Reg Anesth Pain Med, 40 (2015), pp. 213-217
[10]
J.H. Howick.
The philosophy of evidence-based medicine.
Wiley, (2011), 9781444342666, pp. 15
[11]
R. Mungliani.
How do we progress knowledge?.
Pain News, Winter, Br Pain Soc, (2011), pp. 33-35
[12]
J.M. Neal, D.J. Wedel.
Ultrasound guidance and peripheral nerve injury. Is our vision as sharp as we think it is?.
Reg Anesth Pain Med, 35 (2010), pp. 335-337
[13]
T. Saranteas.
Limitations in ultrasound imaging techniques in anesthesia: obesity and muscle atrophy?.
Anesth Analg, 109 (2009), pp. 993-994
[14]
T. Saranteas, D. Karakitsos, A. Alevizou, J. Poularas, G. Kostopanagiotou, A. Karabinis.
Limitations and technical considerations of ultrasound-guided peripheral nerve blocks: edema and subcutaneous air.
Reg Anesth Pain Med, 33 (2008), pp. 353-356
[15]
P. Marhofer, B. Pilz-Lubsczyk, P.A. Lönnqvist, E. Fleischmann.
Ultrasound-guided peripheral regional anaesthesia: a feasibility study in obese versus normal-weight women.
Obes Surg, 23 (2013), pp. 1309-1314
[16]
A. Krol.
Regional anaesthesia with US in obese patient.
Reg Anesth Pain Med, 39 (2014), pp. 23-26
[17]
A.J.R. Macfarlane, C.C.H.R. Brull.
Essential knobology for ultrasound-guided regional anesthesia and interventional pain management.
Atlas of ultrasound guided procedures in interventional pain management, pp. 21-33
[18]
P. Townsley, N. Bedforth, B. Nicholls.
A pocket guide to ultrasound-guided regional anaesthesia – UK.
Sonosite Fuji, (2014), pp. 1-37
[19]
A.C. Krediet, N. Moayeri, R.L. Bleys, G.J. Groen.
Intraneural or extraneural: diagnostic accuracy of ultrasound assessment for localizing low-volume injection.
Reg Anesth Pain Med, 39 (2014), pp. 409-413
[20]
S.J. Montgomery, P.P. Raj, D. Nettles, M.T. Jenkins.
The use of the nerve stimulator with standard unsheathed needles in nerve blockade.
Anesth Analg, 52 (1973), pp. 827-831
[21]
P.P. Raj, R. Rosenblatt, S.J. Montgomery.
Use of the nerve stimulator for peripheral blocks.
Reg Anaesth, 5 (1980), pp. 7
[22]
S.M. Klein, M.S. Melton, W.M. Grill, K.C. Nielsen.
Peripheral nerve stimulation in regional anesthesia.
Reg Anesth Pain Med, 37 (2012), pp. 383-392
[23]
T. Steinfeldt, J. Graf, T. Vassiliou, A. Morin, K. Feldmann, W. Nimphius, et al.
High or low current threshold for nerve stimulation for regional anaesthesia.
Acta Anaesthesiol Scand, 53 (2009), pp. 1275-1281
[24]
W.F. Urmey, J. Stanton.
Inability to consistently elicit a motor response following sensory paresthesia during interscalene block administration.
Anesthesiology, 96 (2002), pp. 552-554
[25]
G.A. Liguori, V.M. Zayas, J.T. YaDeau, R.L. Kahn, L. Paroli, V. Buschiazzo, et al.
Nerve localization techniques for interscalene brachial plexus blockade: a prospective, randomized comparison of mechanical paresthesia versus electrical stimulation.
Anesth Analg, 103 (2006), pp. 761-767
[26]
T. Vassiliou, J. Eider, W. Nimphius, T. Wiesmann, J. de Andres, H.H. Müller, et al.
Dual guidance improves needle tip placement for peripheral nerve blocks in a porcine model.
Acta Anaesthesiol Scand, 56 (2012), pp. 1156-1162
[27]
V.W. Chan, R. Brull, C.J. McCartney, D. Xu, S. Abbas, P. Shannon.
An ultrasonographic and histological study of intraneural injection and electrical stimulation in pigs.
Anesth Analg, 104 (2007), pp. 1281-1284
[28]
C. Robards, A. Hadzic, L. Somasundaram, T. Iwata, J. Gadsden, D. Xu, et al.
Intraneural injection with low-current stimulation during popliteal sciatic nerve block.
Anesth Analg, 109 (2009), pp. 673-677
[29]
X. Sala Blanch, A.M. Lopez, J. Carazo, A. Carrera, J. Pomés, J. Valls-Solé.
Intraneural injection during nerve stimulator-guided sciatic nerve block at the popliteal fossa.
Br J Anaesth, 102 (2009), pp. 855-861
[30]
T. Wiesmann, A. Borntrager, T. Vassiliou, A. Hadzic, H. Wulf, H.H. Müller, et al.
Minimal current intensity to elicit an evoked motor response cannot discern between needle-nerve contact and intraneural needle insertion.
Anesth Analg, 118 (2014), pp. 681-686
[31]
W.G. Voelckel, G. Klima, A.C. Krismer, C. Haslinger, K.H. Stadlbauer, V. Wenzel, et al.
Signs of inflammation after sciatic nerve block in pigs.
Anesth Analg, 101 (2005), pp. 1844-1846
[32]
T.P. Tsai, I. Vuckovic, F. Dilberovic, M. Obhodzas, E. Kapur, K.A. Divanovic, et al.
Intensity of the stimulating current may not be a reliable indicator of intraneural needle placement.
Reg Anesth Pain Med, 33 (2008), pp. 207-210
[33]
P.E. Bigeleisen, N. Moayeri, G.J. Groen.
Extraneural versus intraneural stimulation thresholds during ultrasound-guided supraclavicular block.
Anesthesiology, 110 (2009), pp. 1235-1243
[34]
R. Brull, A. Hadzic, M.A. Reina, M.J. Barrington.
Pathophysiology and etiology of nerve injury following peripheral nerve blockade.
Reg Anesth Pain Med, 40 (2015), pp. 479-490
[35]
S.L. Orebaugh, B.A. Williams, M.L. Kentor.
Ultrasound guidance with nerve stimulation reduces the time necessary for resident peripheral nerve blockade.
Reg Anesth Pain Med, 32 (2007), pp. 448-454
[36]
D. Selander, J. Sjostrand.
Longitudinal spread of intraneurally injected local anaesthetic.
Acta Anaesthesiol Scand, 22 (1978), pp. 622-634
[37]
A. Hadzic, F. Dilberovic, S. Shah, A. Kulenovic, E. Kapur, A. Zaciragic, et al.
Combination of intraneural injection and high injection pressure leads to fascicular injury and neurologic deficits in dogs.
Reg Anesth Pain Med, 29 (2004), pp. 417-423
[38]
C.M. Lupu, T.R. Kiehl, V.W. Chan, H. El-Beheiry, M. Madden, R. Brull.
Nerve expansion seen on ultrasound predicts histologic but not functional nerve injury after intraneural injection in pigs.
Reg Anesth Pain Med, 35 (2010), pp. 132-139
[39]
F.R. Altermatt, T.J. Cummings, K.M. Auten, M.F. Baldwin, S.W. Belknap, J.D. Reynolds.
Ultrasonographic appearance of intraneural injections in the porcine model.
Reg Anesth Pain Med, 35 (2010), pp. 203-206
[40]
S.L. Orebaugh, J.J. Mukalel, A.C. Krediet, J. Weimer, P. Filip, K. McFadden, et al.
Brachial plexus root injection in a human cadaver model: injectate distribution and effects on the neuraxis.
Reg Anesth Pain Med, 37 (2012), pp. 525-529
[41]
A. Krol, M. Szarko, A. Vala, J. De Andres.
Pressure monitoring of intraneural and perineural injections into median radial and ulnar nerves; lesson from cadaveric study.
Anesth Pain Med, 5 (2015), pp. e22723
[42]
A. Vala, L. Phylactides, A. Krol.
Identifying a threshold for the speed of local anaesthetic to be used with B Smart device to avoid false positive results.
Reg Anesth Pain Med, 40 (2015), pp. ESRAS-0192
[43]
J.C. Gadsen, D.M. Lindenmuth, A. Hadzic, D. Xu, L. Somasundarum, K.A. Flisinski.
Lumbar plexus block using high-pressure injection leads to contralateral and epidural spread.
Anesthesiology, 109 (2008), pp. 683-688
[44]
R. Claudio, A. Hadzic, H. Shih, J.D. Vloka, J. Castro, Z. Koscielniak-Nielsen, et al.
Injection pressure by anesthesiologists during simulated peripheral nerve block.
Reg Anesth Pain Med, 29 (2004), pp. 201-205
[45]
P.S. Theron, Z. Mackay, J.G. Gonzalez, N. Donaldson, R. Blanco.
An animal model of syringe feel during peripheral block.
Reg Anesth Pain Med, 34 (2009), pp. 330-332
[46]
C. Siegmueller, S. Ramessur.
A simple low-cost way of measuring injection pressure during peripheral nerve block.
[47]
B.C. Tsui, L.X. Li, J.J. Pillay.
Compressed air injection technique to standardize block injection pressures.
Can J Anaesth, 53 (2006), pp. 1098-1102
[48]
www.PNBmonitoring.com [accessed on 13.10.15].
asdasdasd
Opciones de artículo
Herramientas