Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Tomografía de positrones con 18F-fluorodesoxiglucosa en la valoración de la re...
Información de la revista
Vol. 28. Núm. 2.
Páginas 48-55 (Marzo 2009)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 28. Núm. 2.
Páginas 48-55 (Marzo 2009)
Tomografía de positrones con 18F-fluorodesoxiglucosa en la valoración de la respuesta de los linfomas al tratamiento. Revisión sistemática de la literatura y metaanálisis
18F-fluorodeoxyglucose positron emission tomography in the evaluation of therapy response assessment in lymphomas. Systematic literature review and meta-analysis
Visitas
5913
C. Ramos-Fonta, ÁC. Rebollo Aguirrea, R. Villegas Porterob, A. Romero Tabaresb, M. Gallego Peinadoa, JM. Llamas Elviraa
a Servicio de Medicina Nuclear, Hospital Universitario Virgen de las Nieves, Granada, España
b Agencia de Evaluación de Tecnologías Sanitarias de Andalucía, Sevilla, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (6)
Mostrar másMostrar menos
La presente revisión sistemática de la literatura pretende evaluar el rendimiento de la tomografía de positrones (PET o PET-TAC) de cuerpo entero con 18F-fluorodesoxiglucosa (FDG), como prueba diagnóstica, en la valoración de la respuesta a la quimioterapia y la inmunoterapia en los linfomas, en términos de validez y utilidad, para ello se utilizaron publicaciones de carácter prospectivo. Se realizó una búsqueda bibliográfica en las principales bases de datos disponibles y mediante revisión manual a partir de las listas de referencia de los artículos encontrados. La calidad metodológica de los artículos seleccionados se evaluó mediante el cuestionario QUADAS. Se analizaron 9 publicaciones tras el proceso de filtrado. La calidad metodológica de aquellos, en general, fue aceptable. En pacientes con linfoma de Hodgkin (LH) el valor predictivo negativo de la PET-FDG, después de 2-3 ciclos de quimioterapia, osciló entre el 93,4% (intervalo de confianza [IC] del 95%, 92,6-94,3) y el 100% (IC del 95%, 99,3-100%), y al finalizar el tratamiento el valor predictivo negativo de la PET-FDG osciló entre el 94,3% (IC del 95%, 92,8-95,7) y el 100% (IC del 95%, 97,1-100). En pacientes con LH y masas residuales el metaanálisis de resultados mostró una sensibilidad total del 100% (IC del 95%, 0,753-1) y una especificidad del 0,841% (IC del 95%, 0,699-0,934). La PET-FDG parece ser una herramienta útil en la valoración de la respuesta al tratamiento de pacientes con linfoma. No obstante, ha de recomendarse la realización de nuevos estudios de carácter prospectivo y que, a ser posible, sean con equipos híbridos PET-TAC para determinar su utilidad. © 2008 Elsevier España S.L. y SEMN. Todos los derechos reservados.
Palabras clave:
Tomografía de positrones
F-fluorodesoxiglucosa
Linfoma
Tratamiento
Valoración de respuesta
Revisión sistemática
This systematic review of literature analyze the utility of positron emission tomography (PET or PET-CT) with 18F-fluorodeoxyglucose, as a diagnostic tool in the assessment of response to chemotherapy and immunotherapy in lymphomas, in terms of diagnostic accuracy in prospective publications. A literature search was conducted in major databases and through manual review from the reference lists of articles that were recovered. The methodological quality of the selected items was evaluated using the QUADAS questionnaire. 9 publications were analyzed after the filtering process. The methodological quality of the same was broadly acceptable. In patients with LH, the negative predictive value of FDG-PET after 2-3 cycles of chemotherapy, was ranged between 93.4% (95% CI, 92.6-94.3) and 100% (95% CI, 99.3-100%), and after the treatment, the negative predictive value of PET-FDG, was between 94.3% (95% CI, 92.8-95.7) and 100% (95% CI, 97.1-100). In patients with residual masses and LH, the meta-analysis of results showed a sensitivity of 100% (95% CI, 0.753-1) and a specificity of 84% (95% CI, 0.699-0.934). PET-FDG seems to be a useful tool to evaluate the response to treatment of patients with lymphoma. However, it recommended further prospective studies and that possibly conducted in hybrid PET-CT scans, to determine its usefulness. © 2008 Elsevier España, S.L. and SEMN. All rights reserved.
Keywords:
Positron emission tomography
F-fluorodeoxyglucose Lymphoma
Treatment
Response assessment
Systematic review

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos