Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Tomografía por emisión de positrones/resonancia magnética: presente y futuro
Información de la revista
Vol. 32. Núm. 3.
Páginas 167-176 (Mayo - Junio 2013)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
8102
Vol. 32. Núm. 3.
Páginas 167-176 (Mayo - Junio 2013)
Colaboración especial
Tomografía por emisión de positrones/resonancia magnética: presente y futuro
Positron emission tomography/magnetic resonance: Present and future
Visitas
8102
A.A. Kohana, J.L. Vercher Conejeroa,
Autor para correspondencia
jlvercher@hotmail.com

Autor para correspondencia.
, M.C. Gaetaa, L. Pelegrí Martinezb, P.R. Rosa
a Departamento de Radiología, University Hospitals Case Medical Center/Case Western Reserve University, Cleveland, OH, Estados Unidos
b Departamento de Radiología, Hospital de Sant Joan Despí Moisès Broggi, Barcelona, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Tablas (2)
Tabla 1. Equipos disponibles en el mercado vs. PET/TC
Tabla 2. Posibles indicaciones clínicas en oncología
Mostrar másMostrar menos
Resumen

La PET/RM fue introducida al mercado recientemente tras muchos años de investigación y desarrollo. La simple idea de combinar la capacidad molecular de la PET y sus diversos radiotrazadores con la excelente resolución tisular de la RM y la amplia gama de técnicas multiparamétricas que esta posee generan mucha expectación sobre los posibles usos de esta tecnología. Existen muchos desafíos que hay que resolver, pero el más urgente es la derivación del mapa de atenuación de las secuencias de RM; especialmente porque la PET/TC ya ha demostrado en su corta existencia un gran impacto clínico en oncología, neurología y cardiología. A pesar de estas dificultades, la experimentación clínica se está desarrollando de manera acelerada con el afán de encontrar aquellas áreas donde la PET/RM demuestre superioridad sobre los métodos de imagen existentes. En las pocas publicaciones iniciales hasta la fecha que analizan su papel clínico se describen áreas en donde la migración de la PET/TC hacia la PET/RM se realiza aunque sea solo para eliminar la radiación de la TC. Sin embargo, son muchas las aplicaciones teóricas que la PET/RM podría aportar al campo del diagnóstico por imágenes. En esta revisión haremos un repaso de ellas, la evidencia existente en RM y PET que avalan esas premisas y lo que nuestra experiencia con un equipo de PET/RM nos ha enseñado en el corto periodo de un año.

Palabras clave:
Tomografía por emisión de positrones
Resonancia magnética
Atenuación
Abstract

PET/MRI has recently been introduced onto the market after several years of research and development. The simple notion of combining the molecular capabilities of the PET and its difference available radiotracers with the excellent tissue resolution of the MRI and wide range of multiparametric imaging techniques has generated great expectations upon the possible uses of this technology. Many challenges must be worked out. However, the most urgent one is the derivation of the MRI-based attenuation correction map. This is especially true because the PET/CT has already demonstrated a huge clinical impact within oncology, neurology and cardiology during its short existence. Despite these difficulties, research is being carried out at a rapid pace in the clinical setting in order to find areas in which the PET/MRI is superior to other existing imaging modalities. In the few initial publications found up to date that have analyzed its clinical role, areas have been identified where PET/CT can migrate to PET/MRI, even if only to suppress the CT scan's ionizing radiation. Nonetheless, there are many theoretical applications in which the PET/MRI can further improve the field of diagnostic imaging. In this article, we will review those applications, the evidence existing regarding the MRI and PET that support those premises as well as that which we have learned in the short period of one year with our experience using the PET/MRI.

Keywords:
Positron emission tomography
Magnetic resonance
Attenuation

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos