Buscar en
Radiología
Toda la web
Inicio Radiología Microcalcificaciones con diagnóstico de benignidad en biopsia con aguja gruesa ...
Información de la revista
Vol. 46. Núm. 5.
Páginas 309-314 (Septiembre 2004)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 46. Núm. 5.
Páginas 309-314 (Septiembre 2004)
Microcalcificaciones con diagnóstico de benignidad en biopsia con aguja gruesa (14G): seguimiento y falsos negativos en 76 casos
Microcalcifications with Benign Diagnosis Using Thick Needle Biopsy (14G) Follow-Up and False Negatives in 76 cases
Visitas
7735
Carmen Carreiraa, Cristina Romerob, Angélica Mirab, Javier Martín de Franciscob, José Lombardíab, Efrén García-Valdésb
a Servicio de Diagnóstico por Imagen. Hospital de Fuenlabrada. Fuenlabrada. Madrid. España.
b Unidad de Patología Mamaria. Hospital Virgen de la Salud. Toledo. España.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (6)
Fig. 1. --Nódulo redondeado, micolobulado, denso. A) Carcinoma papilar infiltrante derecho. B) Microcalcificaciones izquierdas. Ambas proyecciones oblicuomediolaterales.
Fig. 2. --Carcinoma papilar. Ecografía. A) Masa lobulada predominantemente sólida con área quística. B) Microcalcificaciones en varios acúmulos.
Fig. 3. --Carcinoma intraductal cribiforme. Pieza de biopsia escisional
Mostrar másMostrar menos
Objetivo: Estudio retrospectivo de la utilidad de la biopsia con aguja 14G de microcalcificaciones mamarias en lo que respecta a su valor para predecir benignidad. Material y métodos: Entre 1998 y 2001 se realizan 76 biopsias de microcalcificaciones con resultado de benignidad utilizando estereotaxia convencional, aguja automática 14G de largo recorrido, más de cinco cilindros, con comprobación radiológica (67%) e histológica (83%) de microcalcificaciones. No se incluyen lesiones de alto riesgo. Se clasifican los hallazgos en concordantes y no concordantes; ante discordancia se pautó biopsia escisional. Siempre, ante resultados inespecíficos, se pautó seguimiento. Se indicó la biopsia escisional en el seguimiento ante cambios mamográficos. Se realiza un seguimiento de al menos dos años y se efectúa la correlación histológica de los casos intervenidos. Resultados: 42 (55%) biopsias presentaron resultados inespecíficos. Se realizó biopsia escisional, por discordancia, en nueve (12%), con dos falsos negativos precoces (2,6%). Se controlaron 62 (81%), y el seguimiento fue incompleto en 14 (18%). En seis biopsias se evidenció un cambio mamográfico en la lesión (8%), el intervalo entre el diagnóstico inicial y los cambios osciló entre 6 y 35 meses, con una media de 22. No se evidenciaron falsos negativos tardíos. Conclusiones: La biopsia con aguja gruesa (BAG) de 14G condicionó un 55% de resultados histológicos inespecíficos, lo que obliga a seguir las lesiones con controles cortos; un 12% de biopsias por discordancia y un 2,6% de falsos negativos.
Palabras clave:
BAG
Microcalcificaciones
Seguimiento
Benignidad
Falsos negativos
Aim: Retrospective study of the usefulness of 14G needle biopsy in predicting benignity of breast microcalcifications. Materials and Methods: Seventy-six biopsies were performed between 1998 and 2001 on microcalcifications with benign diagnosis using conventional stereotactic, automated, large core (14 gauge) needle (more than 5 cylinders), with microcalcifications having been diagnosed radiologically (67%) and histologically (83%). There were included no high risk lesions. All findings were classified as either concordant or non-concordant. Non-concordant findings underwent subsequent exscisional biopsy. Follow-up was prescribed in cases of unspecific results. Excisional biopsy was indicated during follow-up should any mammographic changes have been observed. There were realized follow-up periods of at least 2 years. All cases were submitted to histological correlation. Results: Forty-two biopsies (55%) presented unspecific results. Excisional biopsy due to non-concordant results was performed in 9 cases (12%), with 2 false negatives (2.6%). Sixty-two cases (81%) were controlled, there being incomplete follow-up in 14 cases (58%). There were observed mammographic changes in lesions in 6 biopsies (8%). The time interval between initial diagnosis and mammographic change varied from 6 to 35 months, with the average being 22 months. No false negatives were observed after excisional biopsy. Conclusions: Thick needle biopsy (14 gauge) proved to be definitive in 55% of histologically unspecific results, which necessitated brief follow-ups. It also did so for 12% of those biopsies performed due to non-concordance and 2.6% of false negatives. Any changes occurring late in the follow-up period suggested the possibility of extending such beyond two years in order to establish benignity. The absence of late occurring false negatives, as previously published, related both to the size of biopsy samples and to the fact that a relatively high percentage of lesions were BI-RADS 3 classified.
Keywords:
Thick Needle Biopsy
Microcalcifications
Follow-up
Benignity
False Negatives

Artículo

Opciones para acceder a los textos completos de la publicación Radiología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Radiología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.rx.2019.07.006
No mostrar más