Buscar en
Radiología
Toda la web
Inicio Radiología Análisis del manejo de fracturas ocultas de escafoides mediante la realización...
Información de la revista
Vol. 55. Núm. 3.
Páginas 247-252 (Mayo - Junio 2013)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
16678
Vol. 55. Núm. 3.
Páginas 247-252 (Mayo - Junio 2013)
Original
Análisis del manejo de fracturas ocultas de escafoides mediante la realización precoz de resonancia magnética
Analysis of the management of occult fractures of the scaphoid through early magnetic resonance imaging
Visitas
16678
M.D. Moreno Ramos
Autor para correspondencia
lola67@wanadoo.es

Autor para correspondencia.
, M. Martínez Hervás, P. Sanz Rupp, J. Ramos Medrano
Servicio de Radiodiagnóstico, Hospital San Juan de Dios del Aljarafe, Bormujos, Sevilla, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (6)
Mostrar másMostrar menos
Tablas (1)
Tabla 1. Distribución de pacientes en función de los resultados de la resonancia magnética
Resumen
Introducción

Nuestro objetivo es valorar la utilidad de la resonancia magnética (RM) en el diagnóstico de las fracturas ocultas de escafoides, mostrando las ventajas y el coste comparativo frente al protocolo de seguimiento tradicional.

Material y método

El protocolo de actuación tradicional en nuestro centro consistía en inmovilización y revisiones clínico-radiológicas periódicas (radiología convencional y tomografía computarizada en la fase final del proceso). En el nuevo protocolo, si en el primer control del traumatólogo (10 días post-traumatismo) la radiología convencional seguía siendo negativa se realizaba un protocolo limitado de RM de muñeca (coronal T1 y T2-supresión grasa). Se valoraron los hallazgos visualizados en RM, el tiempo de inmovilización del paciente, el coste económico de ambos protocolos y la dosis de radiación recibida.

Resultados

Se incluyeron 33 casos de pacientes con sospecha clínica de fractura de escafoides y radiología negativa. En 13 pacientes la RM fue negativa. En 12 se confirmó el diagnóstico de fractura de escafoides, 6 asociadas a otra afección. En 8 se diagnosticó otro proceso. El coste del nuevo protocolo fue de 131.06€ por paciente y de 114.41 o 151.06€ para el tradicional, según las revisiones necesarias. Se redujo la dosis de radiación al eliminar la realización de sucesivas exploraciones radiológicas.

Conclusiones

El nuevo protocolo mejora el manejo de estos pacientes, reduciendo el tiempo de inmovilización, mejorando la rigidez articular y disminuyendo el periodo de baja laboral. Permite el diagnóstico de otras lesiones radiológicamente ocultas. El coste es similar e incluso inferior en algunos casos, y la irradiación es menor.

Palabras clave:
Escafoides
Fractura
Resonancia magnética
Análisis de Coste
Abstract
Introduction

We aimed to evaluate the usefulness of magnetic resonance imaging (MRI) in the diagnosis of occult fractures of the scaphoid and to determine the advantages and cost in comparison with the traditional follow-up protocol.

Material and method

The traditional approach at our center consisted of immobilization and periodic clinical and radiological follow-up (plain-film X-rays and computed tomography in the final phase of the process). The new protocol called for a limited MRI study consisting of coronal T1- and T2-weighted fat suppression sequences if the findings at plain-film X-rays continued to be negative at the first follow-up examination with the traumatologist (10 days after trauma). We evaluated the MRI findings, the time the patient was immobilized, the cost of each protocol, and the dose of radiation received.

Results

We included 33 cases of patients with clinically suspected fractures of the scaphoid and negative findings on plain-film X-rays. In 13 patients, the MRI findings were negative. In 12 patients, the MRI findings confirmed the diagnosis of a fracture of the scaphoid, which was associated with other pathology in 6 cases. In 8 patients, another pathological process was diagnosed. The cost of the new protocol was €131.06 per patient; the cost of the traditional protocol was €114.41 or €151.06 per patient, depending on the follow-up studies required. The new protocol reduced the dose of radiation by eliminating successive radiologic studies.

Conclusions

The new protocol improved the management of these patients, reducing the time of immobilization, improving joint rigidity, and reducing the time off work. The limited MRI study makes it possible to diagnose other radiologically occult lesions. The cost of the new protocol is similar to that of the traditional protocol and even lower in some cases. The new protocol results in a reduction in the dose of radiation.

Keywords:
Scaphoid Bone
Fracture
Magnetic resonance imaging
Cost Analysis

Artículo

Opciones para acceder a los textos completos de la publicación Radiología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Radiología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.rx.2024.02.005
No mostrar más