Choque térmico como medida de control de un brote de legionelosis hospitalaria
Superheat-and-flush effect on the control of hospital-acquired Legionella infection
Visitas
5338
Sonia Ragulla, María Luisa Pedro-Boteta, Marian García-Núñeza, María Esteveb, Nieves Sopenaa, Celestino Rey Jolya, Miquel Sabriàa
a Unidad de Enfermedades Infecciosas. Servicio de Medicina Interna. Hospital Universitari Germans Trias i Pujol. Badalona. Barcelona
b Unidad de Medicina Preventiva. Hospital Universitari Germans Trias i Pujol. Badalona. Barcelona. España.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (2)
Fig. 1. Evolución del inóculo promedio de Legionella pneumophila tras el choque térmico en puntos centrales. UFC/l: unidades formadoras de colonias/litro.
Fig. 2. Evolución del porcentaje de puntos de consumo positivos para Legionella pneumophila serogrupo 1 tras el choque térmico.
Mostrar másMostrar menos
Fundamento y objetivo: El choque térmico es un método de desinfección frente a Legionella en circuitos de agua sanitaria. En enero de 1996 se produjo un brote de legionelosis nosocomial (LN) en el Hospital Germans Trias i Pujol. El objetivo de este estudio fue evaluar el impacto ambiental y clínico de un choque térmico. Material y método: Recogida diaria de muestras de agua de puntos centrales y de consumo 3 días antes del choque térmico y los 15 días posteriores. Vigilancia clínica de LN durante 30 días consecutivos tras el choque térmico. Resultados: Tras el choque térmico, el inóculo de Legionella pneumophila en puntos centrales disminuyó, pero aumentó a partir del día 11 y alcanzó su valor máximo a los 15 días. No se detectó L. pneumophila en puntos de consumo a los 4 días. Sin embargo, a partir del día 7, hubo recolonización, que alcanzó el 66% el día 9. No se detectaron casos clínicos de LN durante el período de estudio. Conclusiones: El choque térmico es un método de desinfección, eficaz pero transitorio, que permite actuar de forma inmediata ante un brote de LN.
Palabras clave:
Legionella
Agua sanitaria
Choque térmico
Prevención de la legionelosis
Background and objective: Superheat-and-flush is one of the methods of disinfection used against Legionella in hospital water distribution systems. An outbreak of nosocomial legionellosis (NL) was detected in the hospital Germans Trias i Pujol in January 1996. The aim of this study was to evaluate the impact of this disinfection technique at an environmental and clinical level. Material and method: Water samples were collected daily from central and tap water points 3 days prior to 15 days after superheating and flushing. Clinical surveillance of NL was performed 30 consecutive days following disinfection. Results: After superheat-and-flush, the inoculum of Legionella pneumophila decreased in the central points but increased after day 11, achieving maximum values at 15 days. On the other hand, L. pneumophila was not detected in tap water points after 4 days but recolonization was observed after day 7, achieving 66% at day 9. No clinical cases of NL were detected during the study period. Conclusions: Superheat-and-flush is an effective albeit transitory method of rapid disinfection in outbreaks of NL.
Keywords:
Legionella
Water distribution systems
Superheat-and-flush
Prevention of legionellosis

Artículo

Opciones para acceder a los textos completos de la publicación Medicina Clínica
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Medicina Clínica

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos