Buscar en
Fisioterapia
Toda la web
Inicio Fisioterapia Análisis discriminante del patrón textural ecográfico con matrices de concurr...
Journal Information
Vol. 33. Issue 4.
Pages 157-165 (July - August 2011)
Share
Share
Download PDF
More article options
Visits
2941
Vol. 33. Issue 4.
Pages 157-165 (July - August 2011)
Original
Análisis discriminante del patrón textural ecográfico con matrices de concurrencia como nueva herramienta para el estudio del tendón
Discriminant analysis of the ultrasonographic textural pattern with co-occurrence matrices as a new tool for ultrasonographic of tendon
Visits
2941
J. Ríos-Díaza,b,
Corresponding author
jrios@pdi.ucam.edu

Autor para correspondencia.
, J.J. Martínez-Payáa,c, M.E. del-Baño-Aledoa,c, A. de-Groot-Ferrandod, R. Pérez-Llanesb
a Grupo Investigación Ecografía y Morfo-densitometría Preventiva, Universidad Católica San Antonio, Murcia, España
b Fisioterapia, Departamento de Ciencias de la Salud, Facultad de Ciencias de la Salud, la Actividad Física y el Deporte, Universidad Católica San Antonio, Murcia, España
c Unidad Central de Anatomía, Facultad de Ciencias de la Salud, la Actividad Física y el Deporte, Universidad Católica San Antonio, Murcia, España
d Khronos Fisioterapia, Alicante, España
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (4)
Show moreShow less
Tables (4)
Tabla 1. Estadísticos de control de los modelos discriminantes
Tabla 2. Matriz de confusión para el modelo discriminante global
Tabla 3. Matriz de confusión para el modelo discriminante en mujeres
Tabla 4. Matriz de confusión para el modelo discriminante en hombres
Show moreShow less
Resumen
Objetivo

Evaluar el poder clasificatorio por grupo de edad y sexo de modelos discriminantes (MD) a partir de la ecotextura del tendón de Aquiles (TA).

Material y métodos

Se diseñó un estudio de observacional, transversal sobre 103 sujetos (49 mujeres y 54 hombres) con edades comprendidas entre los 18 y los 53 años (media = 29,8; desviación estándar = 0,86). Se tomaron ecografías transversales bilaterales a 20 mm de la inserción del TA con un ecógrafo Sonosite-Titan (L38 a 5-10 Hz). Se obtuvieron 60 variables texturales a partir de las matrices de concurrencia del nivel de gris (GLCM): contraste, homogeneidad, uniformidad, entropía y correlación para tres escalas (1, 5 y 10 píxeles) y dos orientaciones (0° y 90°) con el programa ImageJ 1.43. Se realizó un análisis multidimensional discriminante exploratorio con el método de inclusión forzosa con SPSS 15.0 (IC del 95%).

Resultados

En el MD global la sensibilidad fue del 74% y la especificidad del 91% para el grupo de edad. En el MD de mujeres la sensibilidad fue del 90% y la especificidad del 97%, mientras que en el MD de los hombres fueron del 96 y el 99%, respectivamente. Tras las validaciones cruzadas entre mujeres y hombres, las sensibilidades se redujeron a un 30%, lo que sugiere que el comportamiento ecotextural del TA en hombres y en mujeres es diferente.

Conclusión

El análisis multivariante de la ecotextura del TA con GLCM mostró una buena sensibilidad y especificidad en la clasificación de los sujetos según el grupo de edad, que mejoraron cuando los modelos se segmentaron según el sexo.

Palabras clave:
Ecografía
Tendones
Análisis multivariante discriminante
Abstract
Objective

The aim of this study was to evaluate the classification power as the age and sex of discriminant models (DM) generated from the echo-texture of the Achilles tendon (AT).

Materials and methods

The design was an observational, cross-sectional study report on 103 subjects (49 females and 54 males) 18 to 53 years old (mean = 29.8, SD = 0.86). We took bilateral transverse ultrasonographies at 20 mm from the insertion of the AT. Sixty variables were obtained from grey level co-occurrence matrices (GLCM): contrast, homogeneity, uniformity, entropy and correlation for three scales (1, 5 and 10 pixels) and two orientations (0° and 90°) with ImageJ 1.43 software. Multidimensional discriminant models were performed with forced inclusion method (CI95%).

Results

The global MD for classification by age group showed a sensitivity of 74% and a specificity of 91%. In the DM women's ultrasound pattern sensitivity increased to 90% and specificity 97%, while sensitivity and specificity of ultrasound pattern DM men were 96% and 99% respectively. When cross-validations were performed for models of women and men, the sensitivities of the models were reduced to 30%, suggesting that the AT echotextural behavior is different.

Conclusion

Multidimensional analysis of Achilles tendon echotexture with GLCM showed good sensitivity and specificity in the classification of subjects by age group that improved when the models were segmented by gender.

Keywords:
Ultrasonography
Tendons
Discriminant analysis

Article

These are the options to access the full texts of the publication Fisioterapia
Member
Socios AEF

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Problemas con el acceso de socios AEF
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
E-mail
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Fisioterapia

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
Tools
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.ft.2019.07.007
No mostrar más