Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Valor clínico y pronóstico de la corrección de atenuación con rayos X en la ...
Información de la revista
Vol. 26. Núm. 2.
Páginas 77-89 (Marzo 2007)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 26. Núm. 2.
Páginas 77-89 (Marzo 2007)
Valor clínico y pronóstico de la corrección de atenuación con rayos X en la SPECT de perfusión miocárdica post-estrés
Clinical and prognostic value of X-ray based attenuation correction in post-stress myocardialperfusion SPECT
Visitas
8589
S. Ruiz Solísa, S. Rodado Marinaa, Á. Soriano Castrejóna, M. Cortés Romeraa, VM. Poblete Garcíaa, AM. García Vicentea, P. Talavera Rubioa, C. Martínezb
a Servicio de Medicina Nuclear. Hospital General de Ciudad Real.
b Unidad de Investigación. Hospital General de Ciudad Real.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (3)
Tabla 1. RESULTADOS DEL ESTUDIO
Tabla 1(. Continuación)
Tabla 2. ESTUDIO ESTADÍSTICO
Mostrar másMostrar menos
Figuras (2)
Objetivo. El propósito del estudio fue validar la técnica de corrección de atenuación con rayos X, aplicada a la tomografía por emisión de fotón único (SPECT) de perfusión miocárdica post-estrés. Material y métodos. Se estudiaron 56 pacientes con sospecha clínica de cardiopatía isquémica y sin antecedentes de infarto de miocardio ni de revascularización coronaria. A todos se les realizó una tomografía por emisión de fotón único (SPECT) de perfusión miocárdica post-estrés ergométrico (38) o farmacológico (18). El tiempo medio de seguimiento clínico fue de 18,6 meses. Se valoraron los estudios tras su reconstrucción mediante la técnica de retroproyección filtrada, y después de aplicar la técnica de corrección de atenuación con rayos X. Los resultados obtenidos se relacionaron con el diagnóstico clínico final. Resultados. Once estudios no corregidos fueron normales y 45 mostraron defectos de perfusión. Tras la corrección de atenuación, se observó la ausencia de defectos significativos de perfusión en 24 casos (42,9 % del total) y finalmente se descartó cardiopatía isquémica en 22. Se observó una mayor frecuencia de normalización del estudio en hombres (p = 0,048; odds ratio = 2.923), pero este hecho no mostró correlación significativa con las siguientes variables: probabilidad pre-test de cardiopatía isquémica, índice de masa corporal superior a 30, presencia o ausencia de factores de riesgo cardiovascular y edad del paciente. Conclusiones. La aplicación de la técnica de corrección de atenuación con rayos X hubiera permitido obviar la realización de un estudio de perfusión de reposo en el 42,9 % de los pacientes, sin modificarse aparentemente la seguridad diagnóstica del test. Este hecho se observó con mayor frecuencia en hombres. El método parece ser seguro, así como tiempo y coste-efectivo.
Palabras clave:
corrección de atenuación, rayos X, SPECT cardíaco, imagen de perfusión miocárdica, cardiopatía isquémica
<i>Objective. The purpose of the study was to validate the X-ray-based attenuation correction technique applied to post-stress myocardial perfusion single photon emission computed tomography (SPECT). Materials and methods. Fifty-six patients with clinically suspected ischemic heart disease and no history of myocardial infarction or coronary revascularization were studied. All patients underwent a myocardial perfusion SPECT after exercise (38) or pharmacological stress (18). Mean clinical follow-up time was 18.6 months. Studies were assessed after reconstruction using the filtered back projection technique and after application of the X-ray-based attenuation correction technique, and the results obtained were related to the final clinical diagnosis. Results. Eleven uncorrected studies were normal, while 45 studies showed perfusion defects. After attenuation correction, absence of significant perfusion defects was observed in 24 cases (42.9 % of all cases), and ischemic heart disease was finally ruled out in 22 cases. A greater study normalization rate was seen in men (p = 0.048; odds ratio = 2,923), but this fact was not shown to be significantly correlated to the following variables: pre-test probability of ischemic heart disease, body mass index greater than 30, presence of cardiovascular risk factors or otherwise, and age. Conclusions. Application of the X-ray-based attenuation correction technique would have allowed for obviating the conduct of a resting perfusion study in 42.9 % of patients without apparently changing the diagnostic safety of the test. This fact was seen more frequently in men. This method seems to be both safe and time- and cost-effective.
Keywords:
attenuation correction, X ray, cardiac SPECT, myocardial perfusion imaging, ischemic heart disease

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos