Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Control de calidad de las aplicaciones de procesado renal
Información de la revista
Vol. 26. Núm. 2.
Páginas 90-99 (Marzo 2007)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 26. Núm. 2.
Páginas 90-99 (Marzo 2007)
Control de calidad de las aplicaciones de procesado renal
Quality assurance of the renal applications software
Visitas
9350
R. del Real Núñeza, PI. Contreras Puertasa, E. Moreno Ortegaa, LM. Mena Baresa, FR. Maza Mureta, JM. Latre Romeroa
a Unidad Clínica de Medicina Nuclear. Hospital Universitario Reina Sofía. Córdoba.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (9)
Fig. 1. --Maniquí básico sobre el que se construye nuestro estudio dinámico sintético. Todos los órganos de interés (riñones, vejiga y arteria aorta) se han simulado mediante formas geométricas simples
Fig. 4. --Curvas de perfusión y función del sistema renal en las cuatro situaciones simuladas: paciente normal (simulación 1), paciente con una obstrucción unilateral derecha con repercusión en la perfusión (simulación 2), paciente con una nefropatía parenquimatosa bilateral
Tabla 1. PARÁMETROS CUANTITATIVOS DE LA PERFUSIÓN RENAL
Tabla 2. PARÁMETROS CUANTITATIVOS DE LA FUNCIÓN RENAL
Mostrar másMostrar menos
Figuras (3)
Mostrar másMostrar menos
Objetivo. Todos los aspectos técnicos de los estudios de Medicina Nuclear deben ajustarse a un programa de garantía de calidad. Sin embargo, se ha prestado poca atención al control de calidad de las aplicaciones de procesado. Nuestro trabajo pretende verificar los programas de análisis empleados en el procesado de los estudios renales (renogramas). Material y métodos. Mediante software hemos construido un modelo dinámico sintético del sistema renal. El modelo consta de dos fases: perfusión y función. Los órganos de interés (riñones, vejiga y arteria aorta) fueron simulados mediante formas geométricas simples. Las captaciones de las estructuras renales vienen descritas por funciones matemáticas. Se simularon distintas curvas de actividad-tiempo de riñón, vejiga y arteria aorta correspondientes a situaciones normales y patológicas mediante la selección adecuada de parámetros. Resultados. No se ha observado ninguna diferencia entre los parámetros de las curvas matemáticas y los datos cuantitativos producidos por el programa de análisis renal. Conclusión. Nuestro procedimiento nos permite verificar los programas de procesado de los estudios renales de forma simple, fiable, reproducible y rápida.
Palabras clave:
control de calidad, aplicación de procesado renal, maniquí matemático
Introduction. The need for quality assurance of all technical aspects of nuclear medicine studies is widely recognised. However, little attention has been paid to the quality assurance of the applications software. Our work reported here aims at verifying the analysis software for processing of renal nuclear medicine studies (renograms). Material and methods. The software tools were used to build a synthetic dynamic model of renal system. The model consists of two phases: perfusion and function. The organs of interest (kidneys, bladder and aortic artery) were simple geometric forms. The uptake of the renal structures was described by mathematic functions. Curves corresponding to normal or pathological conditions were simulated for kidneys, bladder and aortic artery by appropriate selection of parameters. Results. There was no difference between the parameters of the mathematic curves and the quantitative data produced by the renal analysis program. Conclusion. Our test procedure is simple to apply, reliable, reproducible and rapid to verify the renal applications software.
Keywords:
quality control, renal applications software, mathematical phantom

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos