Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular SPECT de perfusión cerebral en la valoracion pronóstica del ictus
Información de la revista
Vol. 22. Núm. 5.
Páginas 327-335 (Septiembre 2003)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 22. Núm. 5.
Páginas 327-335 (Septiembre 2003)
SPECT de perfusión cerebral en la valoracion pronóstica del ictus
Brain perfusion spect in the prognostic assessment of stroke
Visitas
3319
A. Serenaa, JM. Nogueirasa, J. Outomuroa, A. Ortegab, E. Correderab, J. Romerob, V. Del Campoc, LM. Camposa
a Servicios de Medicina Nuclear. Hospital do Meixoeiro. Vigo. Pontevedra.
b Servicios de Neurología. Hospital do Meixoeiro. Vigo. Pontevedra.
c Servicios de Medicina Preventiva. Hospital do Meixoeiro. Vigo. Pontevedra.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (9)
Fig. 1. --Clasificación de los tipos de infarto de acuerdo a su localización.
Fig. 2. --Curvas hemisféricas, diferencial y cociente de ambas. Integración (áreas bajo la curva).
Tabla 1. ÍNDICES NUMÉRICOS DEL SPECT (CUENTAS)
Fig. 3. --Histograma cortical y cálculo de las cuentas del pixel representativo cortical.
Tabla 2. CARACTERISTICAS DEL GRUPO
Tabla 3. COMPARACION DEL GRUPO DE PACIENTES CON TC INICIAL DIAGNOSTICO Y AQUELLOS CON TC NEGATIVO
Tabla 4. CORRELACION DE LOS INDICES CLINICOS Y LOS DERIVADOS DEL SPECT CEREBRAL CON INDEPENDENCIA DEL MOMENTO EVOLUTIVO
Tabla 5. COMPARACION DE LAS CARACTERISTICAS DE LOS PACIENTES Y DATOS DE PRUEBAS DIAGNOSTICAS INICIALES SEGUN SU PRONOSTICO VITAL INMEDIATO
Tabla 6. CORRELACIONES DE LOS INDICES DEL SPECT INICIAL CON EL VOLUMEN FINAL DE LA LESION Y LA DISCAPACIDAD A LOS 30 DIAS
Mostrar másMostrar menos
Objetivo: Comparar el rendimiento de la TC y SPECT de perfusión iniciales y su valor pronóstico respecto a la evolución posterior. Métodos: 25 ictus isquémicos evaluados en su admisión (< 24 h) y a 30-60 días mediante TC, 99mTc-HMPAO-SPECT y escalas neurológicas. El infarto se valoró en la SPECT: visualmente ­"Puntuación total ponderada"­ suma de 22 áreas, y por varios índices semicuantitativos basados en las cuentas hemisféricas. Resultados: Sensibilidad: la TC inicial fue positiva en el 24 % de los casos y la SPECT en el 75 % (73 % en subcorticales puros y 91 % en aquellos con afectación cortical). Localización: concordancia SPECT inicial y TC de control: kappa 0,725. Extensión y severidad: correlación entre índices numéricos y visuales (r: > 0,719); éstos con ligera mejor relación con escalas clínicas. Similar predicción por ambos del tamaño del infarto (Rho > 0,739). Pronóstico inicial: Se observaron diferencias estadísticas entre fallecidos y supervivientes en los índices de la SPECT inicial y en el tamaño del infarto (TC a mediana de 5 días), pero no en la valoración clínica inicial. Pronóstico a largo plazo: La correlación de la SPECT inicial con el estado funcional al mes sólo fue significativa en los índices visuales (Rho: ­0,620). Sin embargo el mejor predictor del estado funcional definitivo fue el Barthel al ingreso. Conclusiones: 1) La SPECT inicial ofrece una buena sensibilidad y predicción del tamaño del infarto; 2) Los índices visuales presentan un rendimiento similar a los más complejos; 3) El volumen del infarto parece ser un determinante critico en el pronóstico vital; otros factores podrían influenciar el estado funcional a largo plazo.
Palabras clave:
SPECT de perfusion cerebral
Cuantificación
Infarto isquémico
Diagnóstico
Valor pronóstico
Purpose: To compare the diagnostic yield of CT scan and perfusion SPECT on admission and its prognostic value in clinical outcome. Methods: 25 ischemic stroke cases were studied on admission (< 24 h) and at 30-60 days by CT scan, 99mTc-HMPAO-SPECT and neurological scales. Infarct size and severity on SPECT were assessed: visually "Total Weighted Score," added value in 22 areas, and by several semiquantitative count-based indices. Results: Sensitivity: the first CT scan was positive in 24 % patients, initial SPECT in 75 % (73 % of pure subcortical infarcts and 91 % of those with cortical involvement). Localization: kappa: 0.725 between SPECT findings on admission and those in control-CT at 5 days. Extent and severity: correlations between count-based and visual indices (r: > 0.719), the latter correlated slightly better with clinical scales. Both predicted similarly (Rho > 0.739) infarct size in CT diagnostic scan. Early Outcome: There were statistical differences between deceased and survivors in SPECT (< 24h) indices and CT-infarct size (mean 5 days), but not in neurological scores on admission. Long term Outcome: Correlation of initial SPECT indices with follow-up functional scores (SNSLP, Barthel index; mean 37 days) was only significant for visual SPECT indices (Rho:­0.560 to ­0.620). Nevertheless the best predictor of functional status on discharge was the Barthel Index on admission. Conclusions: 1) Early SPECT has good sensitivity and accurate infarct size prediction so it can be a useful tool for deciding thrombolytic therapy; 2) Visual scores perform as well as more complex indices; 3) Infarct volume seems to be a critical determinant in vital outcome; other factors (strategic localization, etc.) might influence long term functional status.
Keywords:
Brain perfusion SPECT
Quantification
Ischemic stroke
Diagnosis
Prognostic value

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos