Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Evaluación de la heterogeneidad molecular en tumores neuroendocrinos mediante P...
Información de la revista
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
55
Original
Disponible online el 1 de Mayo de 2024
Evaluación de la heterogeneidad molecular en tumores neuroendocrinos mediante PET/TC con [68Ga]Ga-DOTA-TOC y [18F]FDG
Functional imaging in neuroendocrine tumors: Assessment of molecular heterogeneity using [68Ga]Ga-DOTA-TOC and [18F]FDG PET/CT
Visitas
55
Z. Nogareda Seoanea,
Autor para correspondencia
zulemanogareda@gmail.com

Autor para correspondencia.
, M.C. Mallón Araújoa, A. Calatayud Cubesa, C. Barberán Corrala, Y. Domínguez Novoab, A. Cousillas Castiñeirac, N. Martínez Lagod, J.M. de Matías Leraltae, V. Pubul Nuñeza
a Servicio de Medicina Nuclear, Hospital Clínico Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España
b Servicio de Digestivo, Hospital Clínico Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España
c Servicio de Oncología Médica, Complejo Hospitalario Universitario de Pontevedra, Pontevedra, España
d Servicio de Oncología Médica, Hospital Hospitalario Universitario de Ferrol, Ferrol, España
e Servicio de Endocrinología y Nutrición, Hospital Universitario Lucus Augusti, Lugo, España
Este artículo ha recibido
Recibido 07 febrero 2024. Aceptado 08 abril 2024
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (5)
Mostrar másMostrar menos
Tablas (3)
Tabla 1. Características de los pacientes
Tabla 2. Número de lesiones en función del grado tumoral y radiofármaco
Tabla 3. Pacientes con lesiones mismatch (DOTA-TOC negativa/FDG positiva)
Mostrar másMostrar menos
Resumen
Objetivo

El objetivo del estudio fue evaluar el rendimiento diagnóstico de las PET/TC con [68Ga]Ga-DOTA-TOC y [18F]FDG en pacientes con tumores neuroendocrinos (TNE) confirmados histológicamente, así como la correlación de los hallazgos visualizados con el grado tumoral.

Material y métodos

Se incluyeron 50 pacientes con TNE a los que se les realizó una PET/TC con [68Ga]Ga-DOTA-TOC y otra con [18F]FDG. Se comparó la sensibilidad conjunta de ambas exploraciones, así como la del [68Ga]Ga-DOTA-TOC y la de la [18F]FDG para cada grado tumoral (grado1 [G1], grado2 [G2] y grado3 [G3]). Asimismo, se investigó la sensibilidad del [68Ga]Ga-DOTA-TOC y de la [18F]FDG en función de la variable continua Ki-67. Finalmente, se compararon el número de lesiones detectadas por cada radiofármaco PET para cada grado tumoral.

Resultados

La sensibilidad conjunta de ambas PET/TC (96%) fue mayor que la del [68Ga]Ga-DOTA-TOC (84%) y la [18F]FDG (44%) por separado, objetivándose diferencias significativas. La sensibilidad del [68Ga]Ga-DOTA-TOC fue superior a la [18F]FDG tanto en G1 (p=0,004) como en G2 (p<0,001). En los G3 la realización de ambas exploraciones permitió detectar enfermedad en el 100% de este subgrupo. La sensibilidad de la PET/TC con [68Ga]Ga-DOTA-TOC y con [18F]FDG se correlaciona significativamente con el índice proliferativo Ki-67. En los pacientes G2 el número de lesiones detectadas con el [68Ga]Ga-DOTA-TOC fue superior a la [18F]FDG.

Conclusiones

La sensibilidad conjunta de ambas PET/TC es mayor que la del [68Ga]Ga-DOTA-TOC y [18F]FDG por separado y permite demostrar la heterogeneidad molecular de los TNE metastásicos, sobre todo en aquellos pacientes G2 y G3.

Palabras clave:
Tumor neuroendocrino
Receptores de somatostatina
PET/TC
FDG
Abstract
Objective

The aim of the study was evaluate the diagnostic performance of [68Ga]Ga-DOTA-TOC and [18F]FDG PET/CT in patients with histologically proven neuroendocrine tumors (NETs), as well as the correlation of the visualized findings with the tumor grade.

Material and methods

We included 50 patients with NETs who underwent both [68Ga]Ga-DOTA-TOC and [18F]FDG PET/TC. The pooled sensitivity of both scans was compared, as well as [68Ga]Ga-DOTA-TOC and [18F]FDG for each tumor grade (grade1 [G1], grade2 [G2] and grade3 [G3]). Also, the sensitivity of [68Ga]Ga-DOTA-TOC and [18F]FDG as a function of the continuous variable Ki-67 was investigated. Finally, the number of lesions detected by both PET radiopharmaceuticals for each tumor grade was compared.

Results

The pooled sensitivity of both PET/CT (96%) was higher than [68Ga]Ga-DOTA-TOC (84%) and [18F]FDG (44%) separately, with statistically significant differences. The sensitivity of [68Ga]Ga-DOTA-TOC was higher than [18F]FDG in both G1 (P=.004) and G2 (P<.001). In G3 the performance of both scans detected disease in 100% of this subgroup. The sensitivity of [68Ga]Ga-DOTA-TOC and [18F]FDG PET/CT correlated significantly with the Ki-67 proliferative index. In G2 patients the number of lesions detected with [68Ga]Ga-DOTA-TOC was higher than [18F]FDG.

Conclusions

The performance of both PET/CT, particularly in G2 and G3, demonstrates the molecular heterogeneity of metastatic NETs and contributes to the selection of a more appropriate treatment, particularly in those high-grade patients who may benefit from radionuclide therapy (PRRT).

Keywords:
Neuroendocrine tumor
Somatostatin receptor
PET/CT
FDG.

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos