Buscar en
Revista Colombiana de Reumatología
Toda la web
Inicio Revista Colombiana de Reumatología Fibrosis angiocéntrica eosinofílica intranasal asociada a enfermedad relaciona...
Información de la revista
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
5297
Informe de caso
Fibrosis angiocéntrica eosinofílica intranasal asociada a enfermedad relacionada con IgG4
Intranasal eosinophilic angiocentric fibrosis associated with an IgG4-related disease
Visitas
5297
Jesica Galloa, Cecilia Pisonib, Daniel González Cuetoc, John H. Stoned, Sergio Pairaa,
Autor para correspondencia
pairasergio@fibertel.com.ar

Autor para correspondencia.
a Servicio de Reumatología, Hospital J.M. Cullen, Santa Fe, Argentina
b Servicio de Reumatología, CEMIC, Buenos Aires, Argentina
c Servicio de Anatomía Patológica, Buenos Aires, Argentina
d Rheumatology Unit, Massachusetts General Hospital, Boston, Massachusetts, Estados Unidos
Este artículo ha recibido
Recibido 05 octubre 2016. Aceptado 20 febrero 2017
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Tablas (1)
Tabla 1. Datos de laboratorio del paciente
Resumen

La fibrosis angiocéntrica eosinofílica es una lesión tumoral infrecuente de la órbita ocular y del tracto respiratorio superior. Presentamos el caso de un hombre de 44 años, con antecedentes de severa congestión y obstrucción nasal, y síntomas de sinusitis. Una TAC de senos paranasales mostró una masa focal de tejidos blandos de alta densidad que crecía desde la cara anterior del septum nasal. Se resecó parte del tabique. Los cortes histológicos mostraron una fibrosis concéntrica densa con patrón angiocéntrico y células inflamatorias mixtas. Se demuestra la presencia de fibrosis angiocéntrica eosinofílica. El dosaje sérico de IgG: 1.421mg/dl (valor normal: 540-1.822) y el de IgG4: 168,70mg/dl (valor normal: 6,1-121). Los preparados histológicos fueron inmunomarcados para IgG4 mostrando 50 plasmocitos IgG4(+)/HPF.

Palabras clave:
Fibrosis angiocéntrica eosinofílica
Tracto sinuso-nasal
Enfermedad relacionada con IgG4
Abstract

Eosinophilic angiocentric fibrosis is an uncommon tumefactive lesion of the ocular orbit and upper respiratory tract. We present a 44-year old man with a history of severe nasal congestion and nasal obstruction. The patient also reported symptoms of sinusitis. Submucous thickening tissue had been locally resected and the involved anterior nasal septum cartilage partially removed. Histopathological examination of the biopsy indicated eosinophilic angiocentric fibrosis. A CT scan of the sinuses showed a high-density focal mass of soft tissue arising from the anterior aspect of the nasal septum. Examination under low power view showed dense concentric fibrosis and mixed inflammatory cells. The fibrosis was in an angiocentric pattern, resembling an onionskin. High power view showed a mixture of lymphocytes, plasma cells, numerous eosinophils, and proliferating fibroblasts. A test for serum IgG performed ten years after the patient's initial presentation was 1421mg/dl (normal range 540-1822mg/dl), and the serum concentration of IgG4 was 168.70mg/dl (normal range 6.1-121mg/dl). A review of the original haematoxylin and eosin-stained slides revealed that this case was stained immunohistochemically with an IgG4 stain showing 50 IgG4-positive plasma cells/HPF.

Keywords:
Eosinophilic angiocentric fibrosis
Sinonasal tract
IgG4-related disease

Artículo

Opciones para acceder a los textos completos de la publicación Revista Colombiana de Reumatología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas