Buscar en
Hipertensión y Riesgo Vascular
Toda la web
Inicio Hipertensión y Riesgo Vascular Eficacia de la intervención mediante automedición de la presión arterial en e...
Journal Information
Vol. 22. Issue 3.
Pages 100-108 (April 2005)
Share
Share
Download PDF
More article options
Vol. 22. Issue 3.
Pages 100-108 (April 2005)
Eficacia de la intervención mediante automedición de la presión arterial en el control de la hipertensión arterial
Efficacy of the intervention by self-measurement of blood pressure in arterial hypertension control
Visits
1703
J.P. González-Nuevo Quiñonesa, A. Comas Fuentesa,b,
Corresponding author
angel.comas@sespa.princast.es

Correspondencia: Centro de Salud de Otero. C./ Otero, s/n. 33012 Oviedo.
, M.L. López Gonzálezb, R. Marín Iranzoc, N. Díaz Fernándezd, M. Álvarez-Álvarezd
a Centro de Salud de Otero. Oviedo. España. Servicio de Salud del Principado de Asturias. España.
b Área de Medicina Preventiva. Facultad de Medicina. Universidad de Oviedo. España.
c Servicio de Nefrología. Hospital Central de Asturias. Servicio de Salud del Principado de Asturias. España.
d Centro de Salud de Otero. Oviedo. España
This item has received
Article information
Introducción

Estudiar en condiciones de práctica clínica habitual el efecto de la automedición domiciliaria (AMPA) sobre el descenso de presión arterial (PA) en hipertensos.

Material y métodos

Estudio experimental en Atención Primaria. Participaron 109 pacientes con hipertensión arterial (HTA) ligera, mal controlados en consulta, aleatorizados en grupo intervención (GI), que fue instruido para la AMPA, facilitándosele un automedidor electrónico validado, y grupo control (GC) que siguió el programa de HTA del área. Se controlaron sus PA con una monitorización ambulatoria de la presión arterial (MAPA), al inicio, 18 y 30 meses. Se consideró controlada la PA con media por MAPA de 24 horas menor de 130/80 mmHg. Se registró el consumo de fármacos por dosis diaria definida, el índice de bienestar psicológico y las visitas por HTA y totales al Centro de Salud y otras variables demográficas y factores de riesgo cardiovascular. Se realizó análisis bivariante y multivariante por regresión lineal múltiple y/o regresión logística.

Resultados

El descenso de la PA fue similar en ambos grupos, con tendencia a ser menor en el GI que en el GC a los 30 meses (diferencia de 3,6 mmHg para la PA sistólica y 2,3 mmHg la diastólica en el MAPA de 24 horas; “p”, respectivamente, de 0,036 y 0,052) a expensas de la presión nocturna, no habiendo diferencias significativas en la diurna. No hay diferencias significativas en el control de la PA. El GI consume menos fármacos (1,1 frente a 1,3; p = 0,010).

Discusión

Constatamos un menor descenso de la PA en el grupo de AMPA, en cifras moderadas, a expensas de la presión nocturna. El impacto sobre el proceso asistencial es favorable con un menor consumo de fármacos.

Palabras clave:
hipertensión
monitorización ambulatoria de la presión arterial
automedida de la presión arterial
Introduction

Study the effect of home self-measurement (HSM) on decrease in blood pressure (BP) in hypertensive subjects under usual clinical practice conditions.

Material and methods

Experimental study in Primary Health Care. A total of 109 patients with mild hypertension poorly controlled in the consultation, participated. They were randomized into intervention group (IG), that was instructed on the use of HSM, providing them with a validated electronic self-measurer, and the control group (CG) who followed the area hypertension program. Blood pressure (BP) was measured with ambulatory blood pressure monitoring (ABPM), at onset, 18 and 30 months. BP was considered to be controlled by ABPM with a mean of 24 hours less than 130/80 mmHg. Drug consumption was recorded by daily defined dose, psychological wellbeing index and visits due to hypertension and total visits to the Health Center and other demographic variables and cardiovascular risk factors. Bivariate and multivariate analysis were performed by multiple linear regression and/or logistic regression.

Results

Decrease of BP was similar in both groups, with tendency to be less in the IG than in the CG at 30 months (difference of 3.6 mmHg for systolic BP and 2.3 mmHg for diastolic in the 24 hour ABPM, “p” respectively of 0.036 and 0.052) at expense of nocturnal pressure. There were no significant difference in the daytime pressure. There were no significant differences in the BP control. IG consumed fewer drugs (1.1 vs 1.3; p = 0.010).

Discussion

We observe less BP decrease in the ABPM group, in moderate values, at expense of nocturnal pressure. The impact of the health care process is favorable with less drug usage.

Key words:
hypertension
ambulatory blood pressure monitoring
blood pressure self-measurement

Article

These are the options to access the full texts of the publication Hipertensión y Riesgo Vascular
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Hipertensión y Riesgo Vascular

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
Tools
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos