Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Utilidad de la PET-TC con baja dosis de 18F-FDG en pacientes con sospecha de rec...
Información de la revista
Vol. 31. Núm. 5.
Páginas 249-256 (Septiembre - Octubre 2012)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1914
Vol. 31. Núm. 5.
Páginas 249-256 (Septiembre - Octubre 2012)
Original
Utilidad de la PET-TC con baja dosis de 18F-FDG en pacientes con sospecha de recurrencia de carcinoma colorrectal en métodos diagnósticos convencionales
Utility of low dose 18F-FDG PET-CT in patients with suspected colorectal carcinoma recurrence in conventional diagnostic methods
Visitas
1914
M.A. Ochoa-Figueroaa,
Autor para correspondencia
migue8a@hotmail.com

Autor para correspondencia.
, J. Uña-Gorospeb, A. Allende-Rierab, J.C. Cárdenas-Negrob, J. Muñoz-Iglesiasb, D. Cabello-Garcíab, M. De Sequera-Raholab, E. Martínez-Gimenob
a Departamento de Medicina Nuclear, Hospital Universitario Insular de Gran Canaria, Las Palmas de Gran Canaria, España
b Departamento de Medicina Nuclear, Hospital Universitario de Nuestra Señora de La Candelaria, Santa Cruz de Tenerife, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (5)
Mostrar másMostrar menos
Tablas (5)
Tabla 1. Resultados de sensibilidad y especificidad obtenidos de los 4 grupos
Tabla 2. Características de los pacientes del grupo A
Tabla 3. Características de los pacientes del grupo B
Tabla 4. Características de los pacientes del grupo C
Tabla 5. Características de los pacientes del grupo D
Mostrar másMostrar menos
Resumen
Propósito

Evaluar la eficacia de la 18F-FDG PET-TC en el diagnóstico de la recurrencia del carcinoma colorrectal (RCCR), en pacientes con valores de CEA elevados y/o signos de recurrencia en la TC multidetector (TCMD), así como demostrar que se pueden obtener buenos resultados aplicando los principios ALARA.

Materiales y métodos

Estudio retrospectivo de 54 pacientes con sospecha de RCCR, a los cuales se les realizó una 18F-FDG PET-TC, administrando una dosis media de 222 MBq (6 mCi) de 18F-FDG, desde 07/2007 hasta 01/2011. Excluimos 7 pacientes, estudiando a 47 (27 varones, 20 mujeres, edad media 63 años). La recurrencia se confirmó por histopatología en 14 casos y por evolución clínica en 33.

Los pacientes se dividieron en 4 grupos. A: pacientes con elevación del CEA y sospecha de recidiva en la TCMD. B: elevación del CEA, sin lesiones sospechosas en la TCMD. C: niveles de CEA normales y la TCMD positiva. D: niveles de CEA normales y la TCMD dudosa.

Resultados

: Encontramos una sensibilidad, especificidad, VPP, VPN y exactitud global de 91, 69, 89, 75 y 85, respectivamente. Para el grupo A encontramos una sensibilidad del 100%, en el B una sensibilidad del 75% y especificidad del 100%, para el C una sensibilidad del 89% y especificidad del 71%, finalmente para el D una sensibilidad y especificidad del 100 y 60%, respectivamente.

Conclusión

Aplicando una baja dosis, la 18F-FDG PET-TC tiene un alto rendimiento diagnóstico en pacientes con sospecha de RCCR, acercándose en mayor grado a los criterios ALARA.

Palabras clave:
FDG-PET-TC
Cáncer colorrectal
ALARA
Tiempo de vuelo
LYSO
Abstract
Objective

To evaluate the efficacy of 18F-FDG PET-CT in the diagnosis of recurrence of colorectal cancer (CRC) in patients with elevated values of carcinoembryonic antigen (CEA) and/or signs of recurrence in the multidetector CT (MDCT), and to demonstrate that good results can be obtained applying the ALARA principles.

Material and methods

A retrospective study of 54 patients with suspected CRC, who underwent an 18F-FDG PET-CT, administering a mean dose of 222 MBq (6 mCi) of 18F-FDG, from 07/2007 to 01/2011 was carried out. Seven patients were excluded, thus studying 47 (27 males, 20 females, mean age 63 years). Recurrence was confirmed by histopathology study in 14 cases and by clinical evolution in 33.

The patients were divided into 4 groups. A: patients with elevation of CEA and suspected recurrence in the MDCT. B: elevation of CEA, without suspicious lesions in the MDCT. C: normal levels of CEA and positive MDCT. D: normal levels of CEA and uncertain MDCT.

Results

We found sensitivity, specificity, PPV, NPV and overall accuracy of 91%, 69%, 89%, 75% and 85% respectively. For group A, we found 100% sensitivity, in group B, 75% sensitivity with 100% specificity%, for C, sensitivity was 89% with 71% specificity. Finally, in group D, sensitivity was 100% and specificity 60%, respectively.

Conclusion

Applying a low dose, the 18F-FDG PET-CT has high diagnostic performance in patients with suspicion of CRC, approaching in a higher grade the ALARA criteria.

Keywords:
FDG-PET-CT
Colorectal cancer
ALARA
Time of flight
LYSO

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos