Un modelo de nomograma dinámico que integra el fósforo sérico y el diámetro máximo mejora la precisión diagnóstica de la imagen con [99mTc]Tc-MIBI en pacientes con adenoma paratiroideo y niveles elevados de hormona paratiroidea
A dynamic nomogram model integrating serum phosphorus and longest diameter enhances diagnostic accuracy of 99mTc-MIBI imaging for parathyroid adenoma patients with elevated parathyroid hormone
Visitas
32
L. Zheng, B. Wang, T. Wu, W. Qu
Autor para correspondencia
quwei96311@xjtu.edu.cn

Autor para correspondencia.
Department of Nuclear Medicine, the Second Affiliated Hospital of Xi’an Jiaotong University, Shaanxi, China
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (5)
Mostrar másMostrar menos
Tablas (3)
Tabla 1. Características basales y covariables de los pacientes incluidos en el conjunto de entrenamiento
Tablas
Tabla 2. Resultados del análisis univariante de los datos demográficos y clínicos de los pacientes en el conjunto de entrenamiento
Tablas
Tabla 3. Resultados del análisis de regresión logística en los pacientes del conjunto de entrenamiento
Tablas
Mostrar másMostrar menos
Resumen
Antecedentes

El adenoma paratiroideo (AP) es la causa más común de hiperparatiroidismo primario (HPTP). El diagnóstico por imagen con [99mTc]Tc-metoxiisobutilisonitrilo ([99mTc]Tc-MIBI) se aplica ampliamente en el diagnóstico y localización del AP. Sin embargo, debido a la heterogeneidad individual y a las diferencias funcionales de los adenomas, la eficacia diagnóstica de esta técnica es limitada, lo que a menudo conduce a errores diagnósticos e incluso tratamientos inapropiados.

Métodos

En el presente estudio desarrollamos un nuevo modelo de nomograma dinámico para asistir en el diagnóstico por imagen nuclear del AP. Se incluyó un total de 96 pacientes con AP, distribuidos en un grupo positivo (n=65) y un grupo negativo (n=31), para su análisis.

Resultados

El análisis univariante no reveló diferencias estadísticamente significativas entre ambos grupos en cuanto a sexo, edad y localización del adenoma. Los pacientes del grupo positivo presentaron niveles significativamente más altos de hormona paratiroidea (PTH), calcio sérico, y mayores dimensiones del adenoma (diámetro máximo y mínimo), en comparación con el grupo negativo. No obstante, los niveles de fósforo sérico fueron inferiores en el grupo positivo. El análisis de regresión logística binaria identificó al fósforo sérico y al diámetro máximo del adenoma como predictores positivos independientes. El modelo de nomograma dinámico se generó mediante el software R y análisis de regresión logística (https://zhenglong-1988.shinyapps.io/dynnomapp/). El análisis de la curva ROC). indicó un punto de corte del 59,1% para predecir resultados positivos, con un área bajo la curva (AUC) de 0,965.

Conclusiones

El modelo de nomograma dinámico que integra los niveles de fósforo sérico y el diámetro máximo del adenoma mejora significativamente la precisión diagnóstica del diagnóstico por imagen con radionúclidos en pacientes con AP.

Palabras clave:
Adenoma paratiroideo
Diagnóstico por imagen con [99mTc]Tc-metoxiisobutilisonitrilo ([99mTc]Tc-MIBI)
Fósforo sérico
Diámetro máximo del adenoma paratiroideo
Modelo de diagnóstico con nomograma dinámico
Abstract
Background

Parathyroid adenoma (PA) is the most common cause of primary hyperparathyroidism (PHPT). 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) imaging is widely applied in PA diagnosis and location. However, since the individual heterogeneity and adenoma function differences, the diagnostic efficacy of 99mTc-MIBI imaging is limited, which often leads to misdiagnosis and even mistreatment of PA.

Methods

In the present study, we established a novel dynamic nomogram model to assist the nuclear imaging diagnosis of PA. A total of 96 PA patients, with 65 cases in the positive group and 31 cases in the negative group, were enrolled for further analyzing.

Results

Univariate analysis showed there were no statistically significant differences between the two groups in terms of gender, age, and adenoma location. The patients in the positive group had significantly higher levels in PTH, serum calcium, longest diameter and shortest diameter of adenoma, compared to those in the negative group. But the serum phosphorus levels were lower in the positive group than in the negative group. Binary logistic regression analysis indicated that serum phosphorus and adenoma longest diameter were independent positive predictors. The dynamic nomogram model was generated by R software and logistic regression analysis (https://zhenglong-1988.shinyapps.io/dynnomapp/). The receiver operating characteristics curve (ROC curve) analysis revealed that the cut-off probability for the model to diagnose PA was 59.1%, with AUC values of 0.965.

Conclusions

The novel dynamic nomogram diagnostic model integrating serum phosphorus levels and longest diameter could effectively improve the diagnostic accuracy of radionuclide imaging for PA.

Keywords:
Parathyroid adenoma
99mTc-methoxyisobutylisonitrile (99mTc-MIBI) imaging
Serum phosphorus
Longest diameter of parathyroid adenoma
Dynamic nomogram diagnostic model

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://socios.semnim.es/?ir-a=remnim), previo inicio de sesión como socio.

Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas