Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Localización radioguiada de lesiones ocultas de mama (ROLL)
Información de la revista
Vol. 24. Núm. 6.
Páginas 374-379 (Noviembre 2005)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
ePub
Vol. 24. Núm. 6.
Páginas 374-379 (Noviembre 2005)
DOI: 10.1016/S0212-6982(05)74181-1
Localización radioguiada de lesiones ocultas de mama (ROLL)
Radioguided occult breast lesion location (ROLL)
Visitas
...
M. Cortés Romeraa, R. Pardo Garcíab, A. Soriano Castrejóna, A. García Vicentea, M. Ruiz Díazc, VM. Poblete Garcíaa, M. Carbajo Vicented, S. Rodado Marinaa, S. Ruiz Solísa, P. Talavera Rubioa
a Servicios de Medicina Nuclear. Complejo Hospitalario de Ciudad Real.
b Servicios de Cirug??a General y Digestiva. Complejo Hospitalario de Ciudad Real.
c Servicios de Radiodiagn??stico. Complejo Hospitalario de Ciudad Real. ??
d Servicios de Anatom??a Patol??gica. Complejo Hospitalario de Ciudad Real.
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Tablas (2)
Tabla 1. RESULTADOS ROLL
Tabla 2. ANATOMIA PATOLOGICA DE LAS LESIONES
Mostrar másMostrar menos
Objetivo: Obtener una correcta localización de lesiones ocultas de mama mediante técnicas radioisotópicas. Material y métodos: Se han estudiado 61 pacientes con edades comprendidas entre 32 y 83 años (media de 57 años), con lesiones no palpables de mama, detectadas por mamografía. Seis pacientes tenían antecedentes de cáncer de mama. Sesenta y tres lesiones fueron encontradas. Las lesiones se clasificaron en 34 grupos de microcalcificaciones, 25 nódulos y 4 otras distorsiones de parénquima. Todas las pacientes recibieron una dosis de 0,3-0,5 mCi (11,1-18,5 MBq) de macroagregados de albúmina humana marcados con 99mTc ( 99mTc-MAA) intralesionalmente mediante mamografía estereotáxica o ecografía. Se adquirieron imágenes gammagráficas en proyecciones anterior y lateral, para valorar la correcta colocación del radiotrazador. La localización quirúrgica se realizó mediante la ayuda de una sonda gammadetectora (SGD). En el caso de microcalcificaciones, se realizó comprobación mamográfica de la pieza quirúrgica para confirmar su correcta exéresis. Resultados: La colocación del radiotrazador fue correcta en 60 de 63 casos (95,2 %). Sesenta y una lesiones fueron extraídas totalmente. La anatomía patológica reveló 29 (47,6 %) lesiones malignas y las 32 (52,4 %) restantes fueron benignas. Conclusión: La localización radioguiada de lesiones ocultas de mama mediante técnica radioisotópica es un método sencillo, seguro y bien tolerado por las pacientes.
Palabras clave:
Lesión oculta de mama
Localización radioguiada
Objective: To obtain correct location of occult breast lesions by radiopharmaceutical methods. Material and methods: Sixty-one patients whose ages ranged from 32 to 83 years (average: 57), with non-palpable breast lesions detected by mammography were studied. Six of them had a background of previous breast cancer. Sixty-three lesions were found. The lesions were classified into 34 clusters of microcalcifications, 25 nodules and 4 others parenchymal distortions. All patients received one dose of 0.3-0.5 mCi (11.1-18.5 MBq) of macroaggregates of 99mTc-labelled human serum albumin ( 99mTc-MAA) into the lesion under stereotactic mammographic or ultrasonography guidance. Anterior and lateral scintigraphic images were acquired in order to verify the correct location of the radiopharmaceutical. Intraoperative location of the lesion was performed using a gammaprobe. In case of microcalcifications, the entire removal of the lesion was verified by X-ray of the specimen. Results: Placement of the radiotracer was good in 60 of 63 (95.2 %) cases. Sixty-one lesions were completely removed. Pathological examination revealed 29 (47.6 %) breast cancers and 32 (52.4 %) benign lesions. Conclusion: Radioguided occult breast lesion location by radiopharmaceutical methods is a simple, safe and well-tolerated method by patients.
Keywords:
Occult breast lesion
Radioguided location

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 22,50 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

es en pt
Política de cookies Cookies policy Política de cookies
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.