Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Estimation of the collective ionizing dose in the Portuguese population for the ...
Información de la revista
Vol. 34. Núm. 1.
Páginas 1-8 (Enero - Febrero 2015)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
968
Vol. 34. Núm. 1.
Páginas 1-8 (Enero - Febrero 2015)
Original
Estimation of the collective ionizing dose in the Portuguese population for the years 2011 and 2012, due to nuclear medicine exams
Estimación de la dosis colectiva en la población portuguesa de los años 2011 y 2012, debido a los exámenes de medicina nuclear
Visitas
968
F. Costaa,
Autor para correspondencia
filipa.apbcosta@gmail.com

Corresponding author.
, P. Telesa, A. Nogueirab, A. Barretoc, A.I. Santosc, A. Carvalhod, B. Martinse,f, C. Oliveirae, C. Gasparg, C. Barrosh, D. Nevesi, D. Costae, E. Rodriguesj, F. Godinhok,l, F. Alvesm,n, G. Cardosoc, G. Cantinhok,l, I. Condeo, J. Valep, J. Santosq..., J. Isidoror, J. Pereirad, L. Salgados, M. Rézios,t, M. Vieirat, P. Simãozinhou, P. Almeidav, R. Castrow, R. Parafitaf,x, S. Pintãog, T. Lúcioy, T. Reisd, P. VazaVer más
a Instituto Tecnológico e Nuclear, Campus Tecnológico e Nuclear, Universidade Técnica de Lisboa, Estrada Nacional 10 (km 139,7), 2695-066 Bobadela LRS, Portugal
b NuclearMed, HPA – Hospital Particular de Almada, Rua Manuel Febrero, 85, 2800-455 Almada, Portugal
c Hospital Garcia de Orta, Av. Torrado da Silva, 2801-951 Almada, Portugal
d Centro Hospitalar S. João, Alameda Prof. Hernâni Monteiro, 4200-319 Porto, Portugal
e Fundação Champalimaud, Av. Brasília, 1400-038 Lisboa, Portugal
f Medical Consult, SA, Campo Grande, n° 56–8° A, 1700-093 Lisboa, Portugal
g Hospital de Santa Cruz, Centro Hospitalar de Lisboa Ocidental, Avenida Prof. Dr. Reinaldo dos Santos, 2790-134 Carnaxide, Portugal
h Instituto Português de Oncologia de Coimbra, Francisco Gentil, EPE, Av. Bissaya Barreto, n° 98, 3000-075 Coimbra, Portugal
i Diaton, Unidade de Diagnóstico de Leiria, Rua das Olhalvas, Pousos, 2410-197 Leiria, Portugal
j Quadrantes – Unidade de Radioterapia do Funchal, Rua de Santa Rita, S. Martinho, 9000-238 Funchal, Portugal
k Atomedical, Rua Helena Félix, 11 D, 1600-121 Lisboa, Portugal
l Faculdade de Medicina da Universidade de Lisboa, Av. Prof. Egas Moniz, Hospital de Santa Maria, Cidade Universitária, 1649-028 Lisboa, Portugal
m ICNAS – Instituto de Ciências Nucleares Aplicadas à Saúde, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
n Escola Superior de Tecnologia da Saúde de Coimbra, Rua 5 de Outubro, Apartado, 70063046-854 Coimbra, Portugal
o Clínica Quadrantes Miraflores, Av. General Norton de Matos, 71 R/C Miraflores, 1495-068 Algés, Portugal
p HPP – Medicina Molecular, Av. da Boavista, 119 4050-115 Porto, Portugal
q Instituto Português de Oncologia do Porto, Francisco Gentil, EPE, Rua Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal
r Hospitais da Universidade de Coimbra, Avenida Bissaya Barreto, 3000-076 Coimbra, Portugal
s Instituto Português de Oncologia de Lisboa, Francisco Gentil, EPE, R. Prof. Lima Basto, 1099-023 Lisboa, Portugal
t Hospital da Luz, Avenida Lusíada, 100, 1500-650 Lisboa, Portugal
u Administração Regional de Saúde – Algarve, Largo de São Pedro, n.° 15, 8000-145 Faro, Portugal
v Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências da Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal
w Hospital Geral de Santo António, Largo Prof. Abel Salazar – Edifício Neoclássico, 4099-001 Porto, Portugal
x Hospital Cuf Descobertas, Rua Mário Botas, Parque das Nações, 1998-018 Lisboa, Portugal
y Hospital Beatriz Ângelo, Avenida Carlos Teixeira, 3, 2674-514 Loures, Portugal
Ver más
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (7)
Mostrar másMostrar menos
Tablas (3)
Table 1. Conversion coefficients used for the 28 nuclear medicine radiopharmaceuticals considered in this study. The values are with agreement with DDM2-Portugal and ICRP 53,10 8011 and 106.12
Table 2. Annual collective dose due to all nuclear medicine exams and only cardiac and bone nuclear medicine exams.
Table 3. TOP 10 exams for the year 2010, 2011 and 2012.
Mostrar másMostrar menos
Abstract
Objectives

In 2009–2010 a Portuguese consortium was created to implement the methodologies proposed by the Dose Datamed II (DDM2) project, aiming to collect data from diagnostic X-ray and nuclear medicine (NM) procedures, in order to determine the most frequently prescribed exams and the associated ionizing radiation doses for the Portuguese population. The current study is the continuation of this work, although it focuses only on NM exams for the years 2011 and 2012.

Material and methods

The annual frequency of each of the 28 selected NM exams and the average administered activity per procedure was obtained by means of a nationwide survey sent to the 35 NM centres in Portugal.

Results

The results show a reduction of the number of cardiac exams performed in the last two years compared with 2010, leading to a reduction of the annual average effective dose of Portuguese population due to NM exams from 0.08mSv±0.017mSv/caput to 0.059±0.011mSv/caput in 2011 and 0.054±0.011mSv/caput in 2012. Portuguese total annual average collective effective dose due to medical procedures was estimated to be 625.6±110.9manSv in 2011 and 565.1±117.3manSv in 2012, a reduction in comparison with 2010 (840.3±183.8manSv).

Conclusions

The most frequent exams and the ones that contributed the most for total population dose were the cardiac and bone exams, although a decrease observed in 2011 and in 2012 was verified. The authors intend to perform this study periodically to identify trends in the annual Portuguese average effective dose and to help to raise awareness about the potential dose optimization.

Keywords:
Nuclear medicine
Portuguese population
Collective dose
Effective dose
Dose Datamed II
Resumen
Objetivo

En 2009 y 2010 un consorcio portugués ha sido creado para implementar las metodologías propuestas por el proyecto europeo Datamed II (DDM2), con el objetivo de coleccionar datos de procedimientos de radiología de diagnóstico y medicina nuclear (MN) más frecuentes, así como la dosis asociada en la población portuguesa. Este estudio es una continuación del trabajo, que se centrará en los datos de MN para los años de 2011 y 2012.

Material y Métodos

La frecuencia anual de cada uno de los 28 exámenes de MN seleccionados y la actividad media administrada por procedimiento se obtuvieron a través de una encuesta enviada a los 35 departamentos de MN en Portugal.

Resultados

Los resultados muestran una reducción drástica en el número de procedimientos cardiacos en los últimos dos años, lo que tiene como consecuencia una reducción de la dosis efectiva anual en la población portuguesa derivado de procedimientos de MN de 0,08mSv±0,017 mSv/caput en 2010, a 0,059±0,011 mSv/caput in 2011 y 0,054±0,011 mSv/caput in 2012. La dosis efectiva colectiva media en la población portuguesa es estimada en 625.6±110.9 manSv en 2011, y 565.1±117.3 manSv en 2012.

Conclusiones

Los exámenes cardiacos y óseos fueron más frecuentes y los que más contribuyeron para la dosis total de la población, aunque se verificó una disminución en 2011 y en 2012. Los autores de este trabajo pretenden realizar este tipo de estudios periódicamente para identificar tendencias en los diferentes procedimientos de MN y ayudar a aumentar la conciencia de los profesionales de MN sobre este asunto.

Palabras clave:
Medicina Nuclear
Población Portuguesa
Dosis colectiva
Dosis efectiva
Dose Datamed II

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.remn.2023.12.001
No mostrar más