Regístrese
Buscar en
Revista Española de Cirugía Ortopédica y Traumatología
Toda la web
Inicio Revista Española de Cirugía Ortopédica y Traumatología Cirugía asistida por ordenador. Su utilidad en distintos grados de deformidades...
Información de la revista
Vol. 59. Núm. 4.
Páginas 245-253 (Julio - Agosto 2015)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
ePub
Visitas
260
Vol. 59. Núm. 4.
Páginas 245-253 (Julio - Agosto 2015)
Original
DOI: 10.1016/j.recot.2014.10.002
Cirugía asistida por ordenador. Su utilidad en distintos grados de deformidades preoperatorias
Computer assisted surgery. Its usefulness in different levels of pre-operative deformities
Visitas
260
P. Benavente
Autor para correspondencia
pablo.benavente.rodriguez@gmail.com

Autor para correspondencia.
, C. López Orosa, J.A. Oteo Maldonado, A. Orois Codesal, F.J. García Lázaro
Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario de Fuenlabrada, Fuenlabrada, Madrid, España
Este artículo ha recibido
260
Visitas
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Tablas (6)
Tabla 1. Análisis descriptivo de las variables edad, sexo, IMC y lado intervenido
Tabla 2. Análisis descriptivo de las variables preoperatorias: KSS, flexo y flexión máxima, y eje mecánico
Tabla 3. Análisis comparativo entre el tipo de implante, tiempo de cirugía y tiempo de isquemia
Tabla 4. Análisis del eje mecánico postoperatorio
Tabla 5. Análisis descriptivo de la variable eje mecánico postoperatorio en los distintos subgrupos de eje mecánico preoperatorio
Tabla 6. Comparación de los resultados pre- y postoperatorios de las puntuaciones del KSS, flexión y extensión
Mostrar másMostrar menos
Resumen
Objetivo

Conocer los resultados obtenidos con cirugía asistida por ordenador en nuestro medio en comparación con las técnicas convencionales y analizar la influencia de la navegación ante distintos grados de deformidad preoperatoria.

Material y método

Estudio retrospectivo con 100 pacientes intervenidos de artroplastia total de rodilla mediante técnica convencional y cirugía asistida por ordenador. Se comparó el eje mecánico postoperatorio del miembro inferior en carga entre ambos grupos y en función de la deformidad preoperatoria de cada caso.

Resultados

Se obtiene una alineación óptima con mayor frecuencia al utilizar el sistema de navegación (62%) que mediante una técnica convencional (36%). Los pacientes con deformidades menores de 10° de varo presentaron una media de alineación postoperatoria dentro del intervalo óptimo (0±3° de desviación del eje mecánico neutro) mientras que aquellos con más de 15° de varo muestran una alineación fuera de rango, independientemente de la técnica empleada (p=0,002). En aquellos con una deformidad de entre 10 y 15° de varo preoperatoria los valores de alineación se encontraron más próximos al eje neutro en el grupo de la navegación (178,7°) que en el de técnica convencional (175,5°), aunque estas diferencias no son estadísticamente significativas (p=0,127).

Conclusión

La alineación postoperatoria obtenida con la navegación es mejor que con la técnica convencional, con un menor porcentaje de casos fuera de rango y una mayor precisión en la colocación de los implantes. Se observa un potencial beneficio de la navegación para aquellos casos con deformidades de entre 10 y 15° de varo.

Palabras clave:
Artroplastia total de rodilla
Navegación
Cirugía asistida por ordenador
Alineación postoperatoria
Abstract
Objective

To compare the results obtained with computer assisted surgery with conventional techniques and evaluate the influence of navigation at different levels of preoperative deformity.

Material al method

A retrospective study was conducted on 100 cases with primary total knee arthroplasty performed with conventional or computer assisted surgery. A comparison was made of the post-operative mechanical axis of the lower limb between both groups and in terms of pre-operative deformity.

Results

Optimal alignment is most often obtained by using the navigation system (62%) than by a conventional technique (36%). Patients with deformities under 10° varus showed a mean post-operative alignment within the optimal range (0±3° deviation from the neutral mechanical axis), while those with more than 15° of varus show an alignment out of range, regardless of the technique used (p=.002). In those with a deformity of between 10 and 15° of pre-operative varus alignment, values were found closer to the neutral axis in the navigation group (178.7°) than in the conventional technique (175.5°), although these differences are not statistically significant (p=.127).

Conclusion

Post-operative alignment obtained with navigation is better than with the conventional technique, with a smaller percentage of cases out of range, and greater accuracy in placing implants. A potential benefit was observed in navigation for cases with deformities of between 10 and 15° of varus.

Keywords:
Total knee replacement
Navigation
Computer assisted surgery
Post-operative alignment

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Cirugía Ortopédica y Traumatología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Cirugía Ortopédica y Traumatología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 22,50 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

es en pt
Política de cookies Cookies policy Política de cookies
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.