metricas
Enfermería Intensiva (English Edition) Blood-sparing techniques prevalence in adult intensive care units: A multicentre...
Journal Information
Vol. 35. Issue 4.
Pages e31-e48 Pages 251-428 (October - December 2024)
Cite
Cite
Share
Download PDF
More article options
Visits
843
Vol. 35. Issue 4.
Pages e31-e48 Pages 251-428 (October - December 2024)
Original article
Full text access

Blood-sparing techniques prevalence in adult intensive care units: A multicentre survey study

Prevalencia de las técnicas de ahorro de sangre en unidades de cuidados intensivos de adultos: encuesta multicéntrica
Visits
843
M. Raurell-Torredàa, R.-J. Fernández-Castillob,c,
Corresponding author
rfernandezc@us.es

Corresponding author.
, M.-E. Rodríguez-Delgadod,e, Á. Cobos-Vargasd,e, D.-M. Achury-Saldañaf, E. Cavallof, A. Muriel-Garcíag, S. Arias-Riverah
a Departament d'Infermeria Fonamental i Clínica, Facultat d’Infermeria, Universitat de Barcelona, Barcelona, Spain
b Departamento de Enfermería, Facultad de Enfermería, Fisioterapia y Podología, Universidad de Sevilla, Spain
c Unidad de Cuidados Intensivos, Hospital Universitario Virgen Macarena, Sevilla, Spain
d Unidad de Cuidados Intensivos, Hospital Universitario Clínico San Cecilio, Granada, Spain
e Instituto de Investigación Biosanitaria ibs.GRANADA, Granada, Spain
f Facultad de Enfermería, Pontificia Universidad Javeriana, Coordinadora Red Internacional de Enfermería en Cuidado Crítico, Colombia
g Unidad de Bioestadística, Hospital Universitario Ramón y Cajal, IRYCIS, CIBERESP, Departamento de Enfermería y Fisioterapia, Universidad de Alcalá, Madrid, Spain
h Departamento de Investigación, Hospital Universitario de Getafe, Madrid, Spain
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (1)
fig0005
Tables (3)
Table 1. Participants’ answers to blood-sparing techniques.
Tables
Table 2. Participants’ answers to blood-sparing techniques use according to hospital’s ownership.
Tables
Table 3. Discarded volumes according to type of catheter in ICU with or without protocol specification.a
Tables
Additional material (4)
Abstract
Introduction

Anaemia is a common condition in patients admitted to intensive care units (ICUs). It is also well known that a significant amount of the carbon dioxide produced by health services is likely attributable to blood donation, testing, and the manufacture, storage, and distribution of blood components. To mitigate this, prevention strategies such as blood-sparing techniques are available. There is a lack of knowledge regarding the use of such techniques in ICUs in Spain and Latin America, healthcare systems with very different health expenditures per capita. The aim is to assess the degree of implementation of blood-sparing techniques in these regions.

Methods

Cross-sectional online multicentre survey. 251 ICUs in Spain and 53 in Latin America (20 in Argentina, 20 in Colombia, 13 in Ecuador) participated. A 20-item survey on the use of point-of-care, small-volume tubes (SVT), and closed-blood sampling devices (CBSD) was validated. Effect sizes were calculated using Phi (φ) or Cramer’s V (V).

Results

A response rate of 77% was obtained for Spain and 96% for Latin America. In Spain, the majority of ICUs were affiliated with public hospitals (88.1%, 171/194) while in Latin America, most were associated with private hospitals (56.9%, 29/51). Regarding the use of point-of-care testing, 67.5% of Spanish ICUs, compared to 35.3% of Latin Americans, reported frequent use (V=0.343). In 91.7% of Spanish ICUs and 58.9% of Latin Americans, SVTs were rarely or never used (V=0.380). The use of CBSD was significantly lower in Spain for both arterial and central venous catheters (V=0.336). Private hospitals used more CBSD in arterial catheter than public ones (27% vs 8.3%, V=0.278).

Conclusion

Point-of-care testing can be improved in Latin America, while the use of CBSD and small-volume tubes can be enhanced in Spain. Private hospitals tend to implement blood-sparing techniques more effectively than public hospitals.

Keywords:
Anaemia
Blood-sparing techniques
Closed blood sampling devices
Intensive care nursing
Small volume tubes
Resumen
Introducción

La anemia es frecuente en los pacientes ingresados en unidades de cuidados intensivos (UCI). También es bien sabido que una cantidad significativa del dióxido de carbono producido por los servicios sanitarios es probablemente atribuible a la donación de sangre, las pruebas de laboratorio, almacenamiento y distribución de componentes sanguíneos. Para mitigarlo, existen estrategias de prevención como las técnicas de ahorro de sangre. Existe un desconocimiento sobre el uso de dichas técnicas en las UCI de España y Latinoamérica, sistemas sanitarios con gastos por cápita muy diferentes. El objetivo es evaluar el grado de implantación de las técnicas de ahorro de sangre en estas regiones.

Métodos

Encuesta transversal online multicéntrica. Participaron 251 UCI en España y 53 en Latinoamérica (20 en Argentina, 20 en Colombia, 13 en Ecuador). Se validó una encuesta de 20 ítems sobre el uso de analizadores a pie de cama, tubos de menor volumen y sistemas de retorno de sangre (SRS). Se calculó el tamaño del efecto mediante Phi (φ) o V de Cramer (V).

Resultados

Se obtuvo una tasa de respuesta del 77% para España y del 96% para Latinoamérica. En España, la mayoría de las UCI estaban afiliadas a hospitales públicos (88,1%, 171/194), mientras que en Latinoamérica, la mayoría estaban asociadas a hospitales privados (56,9%, 29/51). En cuanto al uso de analizadores a pie de cama, el 67,5% de las UCI españolas, frente al 35,3% de las latinoamericanas, informaron de un uso frecuente (V=0,343). En el 91,7% de las UCI españolas y en el 58,9% de las latinoamericanas, los tubos de menor volumen se utilizaron raramente o nunca (V=0,380). El uso de SRS fue significativamente menor en España tanto para catéteres arteriales como venosos centrales (V=0,336). Los hospitales privados utilizaron más SRS en catéteres arteriales que los públicos (27% vs 8,3%, V=0,278).

Conclusiones

El uso de analizadores a pie de cama puede mejorarse en Latinoamérica, mientras que el uso de SRS y tubos de menor volumen puede mejorarse en España. Los hospitales privados tienden a aplicar técnicas de ahorro de sangre con mayor eficacia que los públicos.

Palabras clave:
Anemia
Estrategias de ahorro de sangre
Sistemas de retorno de sangre
Enfermería de cuidados intensivos
Tubos de menor volumen
Full Text

What is known?

Anaemia has a high incidence in adult intensive care units with deleterious outcomes.

There is a lack of knowledge about anaemia prevention and blood-sparing techniques implementation.

Sustainability must be seriously considered, especially in ICU nursing interventions related to the use of material resources.

What is the contribution of this?

Blood-sparing techniques must be improved in Spain, especially in public hospitals, and point-of-care testing should be improved in Latin America.

ICU nurses must be trained in blood-sparing techniques, focusing on resource management in order to maintain sustainability.

Implications of the study

The unnecessary use of blood products significantly decreases their availability to patients who really need them, harming the environment by generating a greater carbon footprint. Nurse managers should promote the development of blood extraction protocols related to how to use a closed-blood sampling device, when a test should be performed and how to perform it and discard volume recommended for every catheter. No justification should be given for not implementing blood-sparing techniques in ICUs with high rates of anaemia and transfusion in critically ill patients.

Introduction

Anaemia is common in patients admitted to intensive care units (ICUs). According to an international study, 26% of the 9553 patients presented haemoglobin (Hb) levels <9g/dL on the day of ICU admission, and 44.1% during their stay. The number of blood transfusions was higher in West Europe versus South America on ICU admission [515 (12.6%) vs 87 (9.7%)], and overall [1105 (27.0%) vs 211 (23.4%)].1 The cause of anaemia in critically ill patients is multifactorial (nutritional deficiencies, erythropoietin deficiency, haemolysis, or coagulation anomalies) and is aggravated by repeated blood sampling for diagnostic purposes.2 To treat anaemia, physicians often rely on the transfusion of blood products, and several research studies have linked exposure to blood products to an adverse clinical course, including the development of complications such as infections, multi-organ dysfunction, thrombotic events, congestive heart failure and acute respiratory distress.3

Patient Blood Management programs (PBMs), initially developed for surgical patients, are based on three principles: improving the clinical management of anaemia, minimising iatrogenic blood loss and optimising patients' physiological tolerance to anaemia.3–5 In Spain, a recent study described that only 39 out of 111 (35.14%) analysed ICUs had a PBM program in place.6

To minimise iatrogenic losses and prevent hospital-acquired anaemia (HAA), nurse managers and registered nurses should implement blood-sparing techniques (BST): limit the number of blood draws, use point-of-care testing, use small/pediatric blood tubes, employ closed-blood sampling devices (CBSD), and document all blood losses in the patient's medical record.7 Salisbury8 concluded that for every 50mL of blood drawn, the risk of HAA increases by 18%. According to a study in cardiac and general ICUs, the mean (SD) amount of blood collected over 4 days is 86.3mL (19.58), with approximately 30% being discarded.9 Some studies associate the presence of catheters as a risk factor for HAA, as they facilitate blood extraction for analysis.10

Different surveys have audited the use of BST, all relatively outdated. In England, O’Hare et al.,11 2001, observed that 91% of the ICUs surveyed did not return the discharged volume (VD) (blood diluted with saline and medications extracted prior to laboratory tests) to the patient. In Australia and New Zealand, Harber et al.,12 2006, reported that out of 84 ICUs analysed, none used small-volume tubes for blood draws. According to a summary published in 2017 by Bielby,13 who analysed strategies in Australia, 24.35% of ICUs used CBSD.

Nurses play a key role in professional development. They can contribute significantly to the formulation of appropriate and efficient health policies14 and have the capacity to lead sustainability initiatives by engaging patients, colleagues, administrators, managers and policymakers on the threats of the climate crisis to health and global well-being.15 Transfusions cost and require resources for blood collection, storage, and distribution.16 It is also well-known that a significant amount of the carbon dioxide produced by health services is likely attributable to this process.17,18

The healthcare systems of Spain and Latin America are very different in terms of health expenditure, also with different rates of adoption of policies aimed at improving performance and efficiency to achieve one of the 2015 Sustainable Development Goals (SDGs): “the enjoyment of the highest levels of health that can be achieved”.19 Although all health systems in Latin America adhere to the principle of universal health coverage, as in Spain, only partial coverage is provided in practice. A considerable proportion of demanded health services are covered by beneficiaries’ payments. Health expenditure financed by public funds is considerably below the 6% of GDP recommended by the WHO,19 compared to the 7.7% in Spain.20 Given the existence of collaboration networks between ICUs of both health systems,21 a multicentre research was conducted to evaluate the degree of implementation of blood-sparing techniques in both Spain and Latin America.

MethodologyDesign

A multicentre online cross-sectional survey was conducted in adult ICUs in Spain and some Latin American countries (Argentina, Colombia and Ecuador). The guidelines of the Checklist for Reporting the Results of Internet E-Surveys (CHERRIES) were followed. Inclusion criteria encompassed ICUs of various specialities, including medical, surgical-resuscitation, cardiac, general, burn, traumatology, coronary, and intermediate care units in the participating countries. Pediatric and neonatal ICUs were exclusion criteria because there is high evidence for better use of BST in these units.22 A convenience sample of nurses was selected from each ICU to respond to the survey, reflecting the current practices of the unit where they worked. The unit of analysis was not the nurses themselves, but the usual practices observed in each ICU.

Data collection instrument

The research team designed a survey based on several items identified in the literature regarding strategies for preventing HAA [previously published7,11–13,22 and new research papers about PBM3,4]. In order to ensure that all questions identified as necessary in this first version of the survey (version 1, obtained from an extensive review of the international literature) could be applicable in all the study ICUs, the following validation process was conducted:

  • 1

    Face and content validity of “Version 1”: It aims to confirm that the survey explores all relevant dimensions or domains of the underlying construct. The survey was sent to a panel of 6 experts, Spanish-speaking, according to Skjong’s recommendations23: experience in evidence-based decision-making, knowledge of the topic of study (publications), recognition within the scientific community, willingness to participate, impartiality, and self-confidence. These experts were asked to assess the following parameters for each item in “Version 1” of the survey: sufficiency, clarity, coherence, and relevance. In addition, they were questioned open-ended questions to gain further insight into their opinions and whether they believed more items should be added. The degree of agreement of the answers given by the experts was calculated using descriptive statistical indicators such as the mean, standard deviation, the percentage of consensus among participants, and Aiken's V. The established acceptance criteria:

    • -

      Optimal: Mean 4 and 100% expert consensus.

    • -

      Adequate: Mean greater than or equal to 3 and/or expert consensus >80%.

    • -

      Improbable: Mean greater than or equal to 2 and/or expert consensus >60%.

    • -

      Inadequate: Mean less than 2 and expert consensus <60%.

      Items that received an inadequate rating from more than 50% of experts were eliminated. At the end of this process, “Version 2” of the survey was obtained.

  • 2

    Pilot Test: A pilot test was conducted in 15 ICUs in Spain to ensure that the items in “Version 2” of the survey were understood as defined. For each item, respondents were asked to assess the comprehensibility of the text (poor, acceptable, or good), and space was provided for comments. The time required to complete the survey was measured.

  • 3

    Cross-Cultural Validation of “Version 2” of the survey in Latin-American Spanish: In order to adapt the instrument designed in Spanish, translation was discarded in favour of a lexicosemantic adaptation from standard Spanish in Spain to Latin American Spanish.

Data collection methods

“Google Forms” platform was used to submit the survey. Additionally, two sections were designed, one for the unit information and the other for the survey items. All options were set as mandatory to avoid missing information for each item for the entire survey. Respondents could finish the survey anytime or choose not to submit it by closing the link. The survey could not be withdrawn once submitted. No personal information was collected, nor incentives were offered. Data collection was conducted between 20 February and 2 April 2023.

Sample size

All ICUs associated with the scientific societies participating in the study, the Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC)24 and the Red Internacional de Enfermería en el Cuidado al Paciente Crítico – REINECC25 were identified. This analysis provided the total study population (number of ICUs) that should be contacted in order to identify a nurse participant from each unit with a minimum of 3 years of experience, as recommended in the literature,26 reflecting the most common practice of their unit, not their own. A total of 251 ICUs in Spain and 53 in Latin America (20 in Argentina, 20 in Colombia and 13 in Ecuador) participated.

Data analysis

Categorical variables were expressed in terms of frequency and percentage and compared between ICUs using Fisher's or Chi-Square tests. The effect size was determined using Phi (φ) for 2×2 contingency tables, while Cramer's V (V) was used as an extension of the phi effect size for non-2×2 contingency tables. Effect sizes were considered small values of 0.1, medium 0.3 and large > 0.5. The P-value of <0.05 was considered significant. IBM Statistics for Windows version 19.0 (IBM Corp, Armonk, New York) was used for data analysis.

Ethical considerations

The researchers committed to complying with the Spanish Organic Law 3/2018 of 5 December on the protection of personal data and the guarantee of digital rights, as well as Resolution 008430 of 1993 of the Ministry of Health of the Republic of Colombia. Participants were identified with a code known only to the principal investigator of the research, and a unique alphanumeric code was stored in the database to relate both data. The project was approved by the Ethics Committee (Universitat de Barcelona, Institutional Review Board (IRB00003099). Informed consent was obtained from participants via Google Forms at the time the survey was distributed, indicating the name and contact information of the principal investigator, the purpose of the research, and the average time it would take to answer the survey.

Results

Regarding the survey validation, two Delphi rounds were conducted until 85% of items were rated as optimal: Aiken’s V between 0.82 and 1. In the first Delphi round, two items were eliminated, some items were split, and the order of two items was changed. In order to improve clarity, 14 items were reworded. Finally, the survey consisted of 20 items. In the second round, items 5 and 7 were reworded for clarity. The rounds were conducted blindly, providing experts with feedback from other participants once each round was completed, without identifying the expert who made specific comments.

Appendix S1 (Appendix A. Supplementary data) shows the degree of consensus obtained for each item and the changes undertaken to obtain “Version 2” of the survey. Appendix S2 (Appendix A. Supplementary data) shows the lexical and semantic adaptation from Spanish-Spain to Spanish-Latin America. Appendix S3 (Appendix A. Supplementary data) shows the final version of the survey. The average time required to complete the survey was 6min (ranging from 2−9min).

In Spain, 194 valid responses were received (77% of the units in the SEEIUC database). The response rate exceeded 70% in 12 out of 19 autonomous regions. In the ICUs affiliated with the Latin American Network-REINECC, 20 valid responses were received from Argentina, 19 from Colombia and 12 from Ecuador. The response rate was 96% (Appendix S4, Appendix A. Supplementary data). Some weekly reminders were necessary to achieve this response rate.

In Spain, most ICUs belonged to public hospitals (171/194, 88.1%), 177 (91.2%) were university-affiliated hospitals, and 94 (48.4%) were hospitals with more than 500 beds. The response rate by type of ICU is shown in Fig. 1, with a predominance of mixed ICUs (114/194, 58.8%), units with 8–14 beds, and a nurse-to-patient ratio of 1:2. In Latin America, more than half of the hospitals were private (29/51, 56.9%), 25 (49%) were university-affiliated hospitals, and 23 (45.1%) had less than 200 beds. Mixed ICUs also predominated (26/51, 51%), with a nurse-to-patient ratio ranging from 1:3 to 1:4.

Figure 1.

Answers depending on ICU characteristics.

Responses to each survey item, distinguishing between Spain and Latin America, are presented in Table 1.

Table 1.

Participants’ answers to blood-sparing techniques.

ItemsSpain  Latin America  P-valuePhi (φ) or V Cramer
N=194  N=51 
1  How frequently are small-volume and/or pediatric tubes used in your unit for blood extraction for laboratory tests?         
  Never or rarely  178 (91.7)  30 (58.8)  <0.001  0.380 
  Often  10 (5.2)  10 (19.6)     
  Usually or always  6 (3.1)  11 (21.6)     
2  How frequently are closed-blood sampling devices for CVCs used in your unit?         
  Never or rarely  183 (94.3)  35 (68.6)  0.001  0.344 
  Often  5 (2.6)  4 (7.9)     
  Usually or always  6 (3.1)  12 (23.5)     
3  How frequently are closed-blood sampling devices for PICCs used in your unit?         
  Never or rarely  185 (95.4)  39 (76.5)  <0.001  0.277 
  Often  5 (2.6)  8 (15.7)     
  Usually or always  4 (2.0)  4 (7.8)     
4  How frequently are closed-blood sampling devices for Acs used in your unit?         
  Never or rarely  172 (88.7)  29 (56.9)  <0.001  0.336 
  Often  7 (3.6)  7 (13.7)     
  Usually or always  15 (7.7)  15 (29.4)     
5  Regarding closed-blood sampling devices, please indicate which statements apply to your unit (you can choose more than one):         
  Yes, they are used in my ICU  17 (8.8)  20 (39.2)  <0.001  0.378 
  We don’t have CBSD  167 (86.1)  30 (58.8)     
  They are not used because they increase infection  0 (0.0)  1 (2.0)     
  They are not used because they increase complications like catheter obstruction  3 (1.5)  0 (0.0)     
  Other  7 (3.6)  0 (0.0)     
6  Does your unit have a protocol and/or procedure that specifies how to use the closed-blood sampling devices in vascular catheters (CVC, PICC, arterial)?         
  Yes  13 (6.7)  11 (21.6)  0.003  0.203 
  No / I don’t know  181 (93.3)  40 (78.4)     
7  In your unit, how frequently are gas analyzers used for arterial blood gas measurement instead of sending samples to the laboratory?         
  Never or rarely  40 (20.6)  30 (58.8)  <0.001  0.343 
  Often  23 (11.9)  3 (5.9)     
  Usually or always  131 (67.5)  18 (35.3)     
8  In your unit, how frequently are gas analyzers used for haemoglobin/haematocrit measurement instead of sending samples to the laboratory?         
  Never or rarely  59 (30.4)  30 (58.9)  <0.001  0.321 
  Often  50 (25.8)  3 (5.9)     
  Usually or always  85 (43.8)  18 (35.2)     
9  In your unit, how frequently are gas analyzers used for ion control measurement instead of sending samples to the laboratory?         
  Never or rarely  55 (28.4)  31 (60.8)  <0.001  0.284 
  Often  42 (21.6)  9 (17.6)     
  Usually or always  97 (50.0)  11 (21.6)     
10  Does your unit have a protocol and/or procedure that regulates when different analyses (general analyses, arterial blood gas analyses) should be performed?         
  Yes  67 (34.5)  20 (39.2)  0.622  0.040 
  No / I don’t know  127 (65.5)  31 (60.8)     
11  Does your unit have a protocol and/or procedure that specifies how to perform blood extractions from a vascular catheter (CVC, PICC, arterial)?         
  Yes  98 (50.5)  31 (60.8)  0.210  0.083 
  No / I don’t know  96 (49.5)  20 (39.2)     
12  Does your unit have a protocol that specifies which must be the discard volume for each type of catheter (CVC, PICC, AC)?         
  Yes  60 (30.9)  19 (37.3)  0.403  0.055 
  No / I don’t know  134 (69.1)  32 (62.7)     
13  Do you usually register in your unit the discard volume in the patient’s record?         
  Yes  7 (3.6)  9 (17.6)  0.001  0.231 
  No / I don’t know  187 (96.4)  42 (82.4)     
14  In your unit, when blood is withdrawn from arterial catheters for laboratory tests, what is the volume discarded?         
  <2mL  13 (6.7)  13 (25.5)  <0.001  0.277 
  2.1−5 mL  107 (55.2)  21 (41.2)     
  5.1−8mL  48 (24.7)  7 (13.7)     
  8.1−10mL  25 (12.9)  9 (17.6)     
  More than 10mL  1 (0.5)  1 (2.0)     
15  In your unit, when blood is withdrawn from central venous catheters for laboratory tests, what is the volume discarded?         
  <2mL  1 (0.5)  10 (19.6)  <0.001  0.419 
  2.1−5mL  55 (28.3)  21 (41.2)     
  5.1−  68 (35.1)  7 (13.7)     
  8.1−10mL  65 (33.5)  11 (21.6)     
  More than 10mL  5 (2.6)  2 (3.9)     
16  In your unit, when blood is withdrawn from PICCs for laboratory tests, what is the volume discarded?         
  <2mL  1 (0.5)  12 (23.5)  <0.001  0.448 
  2.1−5mL  54 (27.8)  19 (37.3)     
  5.1−8mL  66 (34.0)  7 (13.7)     
  8.1−10mL  66 (34.0)  11 (21.6)     
  more than 10mL  7 (3.7)  2 (3.9)     
17  When blood is withdrawn from an arterial catheter for laboratory analysis in your unit, how often is the discard volume returned to the circuit?         
  Never or rarely  169 (87.1)  26 (51.0)  <0.001  0.365 
  Often  9 (4.7)  8 (15.7)     
  Usually or always  16 (8.2)  17 (33.3)     
18  When blood is withdrawn from a central venous catheter for laboratory tests in your unit, how often is the discard volume returned to the circuit?         
  Never or rarely  185 (95.4)  36 (70.6)  <0.001  0.359 
  Often  6 (3.1)  5 (9.8)     
  Usually or always  3 (1.5)  10 (19.6)     
19  When blood is withdrawn from a PICC for laboratory tests in your unit, how often is the discard volume returned to the circuit?         
  Never or rarely  188 (96.9)  37 (72.5)  <0.001  0.368 
  Often  4 (2.1)  6 (11.8)     
  Usually or always  2 (1.0)  8 (15.7)     
20  In a patient with continuous intravenous insulin therapy, which kind of blood sample is used for glucose analysis in your unit?         
  Always arterial  17 (8.8)  4 (7.8)  <0.004  0.251 
  Always venous  2 (1.0)  6 (11.8)     
  Always capillary  86 (44.3)  20 (39.2)     
  Arterial, venous and capillary  86 (44.3)  21 (41.2)     
  Subcutaneous sensor  3 (1.5)  0 (0.0)     

CBSD: closed-blood sampling device; CVC: central venous catheter; PICC: peripherally inserted central catheter; AC: arterial catheter.

Restrictive frequency of blood draws

A protocol specifying when to perform various analyses (e.g., general, blood gas analysis) was not available or unknown in 65.5% of ICUs in Spain and 60.8% in Latin America (p=0.622, φ=0.040) (Item 10). Regarding the use of point-of-care testing, in Spain, 67.5% of ICUs versus 35.3% in Latin America (p<0.001, V=0.343) always or routinely used gas analysers for blood gas analysis (Item 7). For haematocrit and/or haemoglobin monitoring, it was 43.8% in Spain vs. 35.2% in Latin America (p<0.001, V=0.321) (Item 8), and for ion monitoring, it was 50.0% in Spain vs. 21.6% in Latin America (p<0.001, V=0.284) (Item 9).

Use of small-volume tubes (SVT) and closed-blood sampling devices (CBSD)

The Spanish nurses, 91.7%, never or rarely used small-volume tubes, compared to 58.8% in Latin America (p<0.001, V=0.380) (Item 1). Latin American nurses used significantly more CBSD than Spanish nurses in all types of catheters (items 2, 3 and 4). CBSD availability is smaller in Spanish ICUs (item 5). In Spain, 93.3% and in Latin America 78.4% (p=0.003, φ=0.203) of nurses lacked or were unaware of a protocol explaining how to use CBSD (Item 6). When comparing by hospital ownership, 7.3% of public hospitals had protocols explaining how to use CBSD versus 19.2% of private hospitals (p=0.016, φ=0.165) (Table 2). It is also observed that private hospitals use significantly more SVT and CBSD (Table 2).

Table 2.

Participants’ answers to blood-sparing techniques use according to hospital’s ownership.

ItemPublic  Private  P-valuePhi (φ) or V Cramer
N=193  N=52 
1  Small-volume tubes usage         
  Never or rarely  171 (88.6)  37 (71.1)  0.003  0.199 
  Often  12 (6.2)  8 (15.4)     
  Usually or always  10 (5.2)  7 (13.5)     
2  CBSD in CVCs         
  Never or rarely  17 (92.2)  40 (76.9)  <0.001  0.210 
  Often  6 (3.1)  3 (5.8)     
  Usually or always  9 (4.7)  9 (17.3)     
3  CBSD in PICCs         
  Never or rarely  180 (93.3)  44 (84.6)  <0.001  0.126 
  Often  8 (4.1)  5 (9.6)     
  Usually or always  5 (2.6)  3 (5.8)     
4  CBSD in ACs         
  Never or rarely  169 (87.6)  32 (61.5)  <0.001  0.278 
  Often  8 (4.1)  6 (11.5)     
  Usually or always  16 (8.3)  14 (27.0)     
6  Does your unit have a protocol and/or procedure that specifies how to use the closed-blood sampling devices in vascular catheters (CVC, PICC, arterial)?         
  Yes  14 (7.3)  10 (19.2)  0.016  0.165 
  No / I don’t Know  179 (92.7)  42 (80.8)     
12  ¿Does your unit have a protocol that specifies the discard volume for each type of catheter (CVC, PICC, AC)?         
  Yes  57 (29.5)  22 (42.3)  0.095  0.112 
  No / I don’t know  136 (70.5)  30 (57.7)     
13  Do you usually register in your unit the discard volume in the patient’s record?         
  Yes  8 (4.1)  8 (15.4)  0.008  0.186 
  No / I don’t know  185 (95.9)  44 (84.6)     
14  Discarded volume in ACs         
  <2mL  18 (9.3)  8 (15.4)  0.442  0.124 
  2.1−5 mL  104 (53.9)  24 (46.2)     
  5.1−8 mL  45 (23.3)  10 (19.2)     
  8.1−10mL  25 (13.0)  9 (17.3)     
  >10mL  1 (0.5)  1 (1.9)     
15  Discarded volume in CVCs         
  <2mL  6 (3.1)  5 (9.6)  0.048  0.198 
  2.1−5 mL  56 (29.0)  20 (38.5)     
  5.1−8 mL  63 (32.6)  12 (23.1)     
  8.1−10mL  64 (33.2)  12 (23.1)     
  >10mL  4 (2.1)  3 (5.8)     
16  Discarded volume in PICCs         
  <2mL  7 (3.6)  6 (11.5)  0.068  0.189 
  2.1−5 mL  55 (28.5)  18 (34.6)     
  5.1−8 mL  63 (32.6)  10 (19.2)     
  8.1−10mL  62 (32.1)  15 (28.8)     
  >10mL  6 (3.1)  3 (5.8)     
  When blood is withdrawn from arterial catheters for laboratory analysis in your unit, how often is the discarded volume returned to the circuit?         
17  Never or rarely  163 (84.5)  32 (61.6)  0.001  0.235 
  Often  11 (5.7)  6 (11.5)     
  Usually or always  19 (9.8)  14 (26.9)     
18  When blood is withdrawn from central venous catheters for laboratory analysis in your unit, how often is the discard volume returned to the circuit?         
  Never or rarely  181 (93.8)  40 (76.9)  0.008  0.234 
  Often  6 (3.1)  5 (9.6)     
  Usually or always  6 (3.1)  7 (13.5)     
19  When blood is withdrawn from PICCs for laboratory analysis in your unit, how often is the discard volume returned to the circuit?         
  Never or rarely  183(94.8)  42 (80.8)  0.010  0.221 
  Often  6 (3.1)  4 (7.7)     
  Usually or always  4 (2.1)  6 (11.5)     

CBSD: closed-blood sampling device; CVC: central venous catheter; PICC: peripherally inserted central catheter; AC: arterial catheter.

Documenting discard volumes (VD)

Spanish nurses answered that in 49.5% of the cases, they lacked or were unaware of a protocol specifying how to perform blood extractions from a vascular device (CVC, PICC line or arterial), while in Latin America, 39,2% (p=0.210, φ=0.083) (Item 11). In this regard, 69.1% of the nurses in Spain and 62.7% (p=0.403, φ=0.055) in Latin America lacked or were unaware of a protocol specifying the VD for each type of catheter (Item 12). When comparing by hospital ownership, 29.5% of public hospitals had protocols that regulate VD versus 42.3% of private hospitals (p=0.095, φ=0.112). (Table 2). VD decreases when a protocol specifies this practice (Table 3). Furthermore, 96.4% of Spanish nurses and 82.4% of Latin American nurses (p=0.001, φ=0.231) did not systematically document VD in the patient's medical record (Item 13). More information was recorded in private hospitals than in public hospitals (15.4% vs. 4.1%, p=0.008, φ=0.186). (Table 2). In Latin America, VDs were significantly lower than in Spain for all types of catheters (p<0.001, items 14, 15, and 16). In addition, nurses return this volume more frequently to venous or arterial circuits (p<0.001, items 17, 18 and 19). The VDs reported by private hospitals were lower than those of public ones, being significant in CVCs. The return frequency of VDs was higher for all types of catheters in private hospitals (Table 2).

Table 3.

Discarded volumes according to type of catheter in ICU with or without protocol specification.a

Discarded volume (mL)Protocolised ICU  Non protocolised ICU  P valueV Cramer
N=79  N=166 
14  AC         
  <2mL  8 (10.1)  18 (10.8)  0.045  0.199 
  2.1−5 mL  48 (60.8)  80 (48.2)     
  5.1−8 mL  11 (13.9)  44 (26.5)     
  8.1−10mL  10 (12.7)  24 (14.5)     
  >10mL  2 (2.5)  0 (0.0)     
15  CVC         
  <2mL  4 (5.1)  7 (4.2)  0.293  0.142 
  2.1−5 mL  26 (32.9)  50 (30.1)     
  5.1−8 mL  17 (21.5)  58 (34.9)     
  8.1−10mL  29 (36.7)  47 (28.3)     
  >10mL  3 (3.8)  4 (2.4)     
16  PICC         
  <2mL  4 (5.1)  9 (5.4)  0.327  0.138 
  2.1−5 mL  26 (32.9)  47 (28.3)     
  5.1−8 mL  18 (22.8)  55 (33.1)     
  8.1−10mL  26 (32.9)  51 (30.7)     
  >10mL  5 (6.3)  4 (2.4)     

CVC: central venous catheter; PICC: peripherically inserted central catheter; AC: arterial catheter.

a

ICUs are classified according to the answers to item 12 (Does your unit have a protocol specifying what the discarded volume should be for each type of catheter (CVC, PICC, AC)?) Those who answered “Yes” are protocolised ICUs and those who answered “No/I don't Know” are non-protocolised ICUs.

Finally, to monitor glycaemia per hour in intensive continuous endovenous insulin therapy, only 8.8% of ICUs in Spain used arterial blood, 44.3% combined different types of blood samples (arterial, venous, or capillary), or used capillary samples on all occasions. Within Latin America, 7.8% used arterial blood, 41.2% used either blood indiscriminately, and 39.2% used only capillary samples (item 20).

Discussion

The point-of-care use is observed to be higher in Spain than in the participating Latin American countries, achieving an optimal response rate higher than 70% as recommended.27 However, the opposite is noted regarding the use of SVT and CBSD. This discrepancy is probably explained by the prevalence of public hospitals in Spain and private hospitals in Latin America. Private hospitals also demonstrate a higher awareness of blood conservation. Therefore, VD requirements for each type of catheter need to be standardised, although, in Latin America participating countries, less VD is used while more is recorded than in Spain. A study in Spain conducted by Quintana concluded that hospitals with PBM protocols transfused 12.24% of patients versus 16.30% in hospitals without PBM (p=0.264).6

Restrictive frequency of blood draws

The use of PoC in Spain is similar to the rates reported in Australia in 2017.13 According to Ullman,22 the most common indication for PoC is blood gas analysis, as confirmed in this study (82%). On the other hand, electrolyte, urea, and liver function monitoring (24%) and haemoglobin/haematocrit levels (23%) are analysed by PoC in a lower percentage than in Latin America participating countries.

Use of Small-Volume Tubes and Closed-Blood Sampling Devices (CBSD)

The use of small-volume or pediatric tubes in adult ICUs in Spain is almost 8%, slightly better than the study conducted by Harber in Australia and New Zealand,12 which identified that none of the 84 ICUs analysed used them. However, ten years later, other authors detected a use rate of 47.4%, in the same country, similar to that observed in Latin America.13 Previsdomini7 reported a utilisation rate of 10.3% for SVT and 74.5% for CBSD in Switzerland. The lack of cost-effectiveness studies makes it unclear which blood-sparing technique is more recommended.16,28 Current evidence has not identified an increased risk of infection or catheter obstruction associated with CBSD use.29 Currently, no evidence has been found to explain the higher use of SVT or CBSD in private hospitals compared to public hospitals.

Documenting discard volumes (VD)

In Latin America participating countries, the percentage of nurses that returned VD to the patient was higher than the global rate of 27.8% reported by Previsdomini in Switzerland.7 Although the implementation of protocols specifying the VD for each type of catheter remains low in Latin America, discard volumes are significantly lower than those in Spain. This may be attributable to a higher frequency of VDs registration in private hospitals, which, according to our sample, are more prevalent in Latin America than in Spain. A systematic review by Keogh30 was unable to perform a meta-analysis of VD data owing to the high heterogeneity of the studies. Regarding the method of blood glucose analysis during intensive insulin therapy, neither Spain nor Latin America follows the recommendation to use arterial blood for glucose analysis in critically ill patients.31 Therefore it cannot be a cause of anaemia in these patients. Nurses play a crucial role ensuring the efficacy and safety of blood-sparing techniques and have the responsibility for sustainable interventions with the environment. They are often also responsible for developing blood extraction protocols, which, as McSporran suggested,5 need improvement in terms of VD documentation. Standardisation of care could be achieved by frequent training on PBM bundles.4 Latin American countries have shown a more efficient use of resources related to blood conservation, probably because they dispose of fewer public funds.

Limitations

Despite selecting participating nurses based on their ICU experience and knowledge of standard blood extraction procedures, there might still be intra-ICU variability in the responses provided by each nurse representing the unit. We assumed this limitation to obtain a representative sample of all participating ICUs, avoiding the over/under-representation of any of them if the survey had been sent to all the SEEIUC or REINECC partner nurses. In order to compensate for this, it was emphasized at the beginning of the survey that each participant had to respond according to the most common practice in their unit, rather than according to their own.

Another potential limitation of the study could be the sample size, which, although substantial for ICUs, may not be entirely representative. All Spanish autonomous regions are represented, but 7 of the 19 (36.8%) did not achieve a minimum response rate of 70% despite contacting potential participants on a weekly frequency. It was not possible to analyze the data in Mexico and Peru, speaking-Spanish countries affiliated with the Latin American Network-REINECC because weren’t able to achieve a compliance with the deadlines for applying the survey.

Moreover, a significant majority of Spanish units are state-owned, which could affect comparative results with private units, which are more common in the Latin American sample. It should be taken into consideration that responses may be influenced by social desirability bias, a bias present in the completion of any questionnaire. To minimise this bias, the unit managers were contacted to confirm the data whenever any incongruent or extreme responses were observed.

Conclusions

Point-of-care use could be improved in Latin America participating countries, while in Spain, the use of small-volume tubes and close-blood sampling devices is necessary. Private hospitals demonstrate a better ability to adopt blood-sparing techniques and reduce discard volumes. They also tend to document these practices in charts. Investment in material resources and training on anaemia prevention strategies improve patient safety and environmental sustainability. Future studies should examine which strategies are more cost-effective, such as CBSD versus SVT.

Ethics statement

This study followed in full accordance the ethics principles of the Declaration of Helsinki. Nonetheless, it has not been approved and independently reviewed by an ethical board due to the characteristics of the manuscript.

Funding statement

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Conflict of interest

M. Raurell-Torredà and S. Arias-Rivera are Editors of the journal Enfermería Intensiva, therefore, for the evaluation of this article, the procedure described in the publication guidelines for such cases has been utilized. The remaining authors declare no conflicts of interest.

Data availability statement

The data that support the findings of this study are available on request from the corresponding author, Rafael-Jesús Fernández-Castillo.

Acknowledgements

We would like to thank all the hospitals and their participant nurses who kindly gave us their appreciated time to answer the survey. We also would like to thank all the experts who participated in the survey’s validation.

Appendix A
Supplementary data

The following are Supplementary data to this article:

Icono mmc1.docx
Icono mmc2.docx
Icono mmc3.docx
Icono mmc4.docx

References
[1]
J.-L. Vincent, U. Jaschinski, X. Wittebole, J.-Y. Lefrant, S.M. Jakob, on behalf of the ICON Investigators, et al.
Worldwide audit of blood transfusion practice in critically ill patients.
[2]
S. Lasocki, F. Pène, H. Ait-Oufella, C. Aubron, S. Ausset, P. Buffet, et al.
Management and prevention of anemia (acute bleeding excluded) in adult critical care patients.
Ann Intensive Care, 10 (2020), pp. 97
[3]
M. Franchini, G. Marano, E. Veropalumbo, F. Masiello, I. Pati, F. Candura, et al.
Patient Blood Management: a revolutionary approach to transfusion medicine.
Blood Transfus Trasfus Sangue, 17 (2019), pp. 191-195
[4]
P. Helmer, S. Hottenrott, A. Steinisch, D. Röder, J. Schubert, U. Steigerwald, et al.
Avoidable blood loss in critical care and patient blood management: scoping review of diagnostic blood loss.
J Clin Med, 11 (2022), pp. 320
[5]
W. McSporran.
Role of the nurse in patient blood management and treating anaemia.
Nurs Stand R Coll Nurs G B 1987, 36 (2021), pp. 73-78
[6]
M. Quintana-Diaz, K. Nanwani-Nanwani, P. Marcos-Neira, A. Serrano-Lázaro, R. Juarez-Vela, E.M. Andrés-Esteban.
Epidemiología de la transfusión sanguínea en los Servicios de Medicina Intensiva en España: “Transfusion Day”.
Med Intensiva, 46 (2022), pp. 123-131
[7]
M. Previsdomini, J. Colombo, B. Cerutti, B. Gerber, A. Hofmann, A.F. Chiesa, et al.
Dissemination of patient blood management practices in Swiss intensive care units: a cross-sectional survey.
Swiss Med Wkly, 152 (2022),
[8]
A.C. Salisbury, K.J. Reid, K.P. Alexander, F.A. Masoudi, S.-M. Lai, P.S. Chan, et al.
Diagnostic blood loss from phlebotomy and hospital-acquired anemia during acute myocardial infarction.
Arch Intern Med, 171 (2011), pp. 1646-1653
[9]
J. Holland, R.M. Peralta, R.L. Moss, K. Feane, J. Uprichard.
A single‐centre review of iatrogenic anaemia in adult intensive care.
Transfus Med, 30 (2020), pp. 196-200
[10]
R. Juárez-Vela, E.M. Andrés-Esteban, V. Gea-Caballero, J.L. Sánchez-González, P. Marcos-Neira, A. Serrano-Lázaro, et al.
Related factors of anemia in critically ill patients: a prospective multicenter study.
J Clin Med, 11 (2022), pp. 1031
[11]
D. O’Hare, R.J. Chilvers.
Arterial blood sampling practices in intensive care units in England and Wales: forum.
Anaesthesia, 56 (2001), pp. 568-571
[12]
D.C.R. Harber, K.J. Sosnowski, R.M. Hegde.
Highly conservative phlebotomy in adult intensive care—a prospective randomized controlled trial.
Anaesth Intensive Care, 34 (2006), pp. 434-437
[13]
27th Regional Congress of the ISBT, Copenhagen, Denmark, June 17-21, 2017. Vox Sang. 2017 Jun;112 Suppl 1(Suppl 1):5-295. doi: 10.1111/vox.12530. Erratum in: Vox Sang. 2017 Aug;112(6):601-602.
[14]
A. Hajizadeh, V. Zamanzadeh, E. Kakemam, R. Bahreini, R. Khodayari-Zarnaq.
Factors influencing nurses participation in the health policy-making process: a systematic review.
[15]
H. Baid, E. Damm.
Reducing critical care’s carbon footprint with financial and social co-benefits.
Intensive Crit Care Nurs, 64 (2021),
[16]
A.P. Vlaar, S. Oczkowski, S. de Bruin, M. Wijnberge, M. Antonelli, C. Aubron, et al.
Transfusion strategies in non-bleeding critically ill adults: a clinical practice guideline from the European Society of Intensive Care Medicine.
Intensive Care Med, 46 (2020), pp. 673-696
[17]
S.P. Hibbs, S. Thomas, M.F. Murphy.
Convergence of zero carbon healthcare with patient blood management.
[18]
S. McAlister, A.L. Barratt, K.J. Bell, F. McGain.
The carbon footprint of pathology testing.
Med J Aust, 212 (2020), pp. 377-382
[19]
Kanavos P, Parkin GC, Kamphuis B, Gill J, de A. Visión general del sistema de salud de América Latina. Un análisis comparativo del espacio fiscal en la asistencia sanitaria. Retrieved from: https://www.lse.ac.uk/business/consulting/assets/documents/latin-america-healthcare-system-overview-report-spanish.pdf.
[20]
Ministerio de Sanidad - Sanidad en datos - Gasto sanitario público: millones de euros, porcentaje sobre el PIB y euros por habitante según los países de Unión Europea (UE-28). [Accessed 13 February 2024]. Available from: https://www.sanidad.gob.es/estadEstudios/sanidadDatos/tablas/tabla30_1.htm.
[21]
Asociaciones. FEPIMCTI. s. f., Available from: https://fepimcti.org/asociaciones/.
[22]
A.J. Ullman, S. Keogh, F. Coyer, D.A. Long, K. New, C.M. Rickard.
‘True Blood’ The Critical Care Story: an audit of blood sampling practice across three adult, paediatric and neonatal intensive care settings.
Aust Crit Care, 29 (2016), pp. 90-95
[23]
Skjong R, Skjong R, Wentworth BH, Wentworth BH. Expert judgement and risk perception. s. f.
[24]
Sociedad Española de Enfermeria Intensiva y Unidades Coronarias. s. f., Available from: https://seeiuc.org/.
[25]
Red Internacional de Enfermería en el Cuidado al Paciente Crítico – REINECC – Redes Internacionales de Enfermería. s. f., Available from: http://riesweb.site/redes/reinecc/.
[26]
M.D. Barth, B. Quatrara, S.M. Burns, M.R. Conaway.
Blood conservation: what is current blood draw practice?.
J Infus Nurs Off Publ Infus Nurses Soc, 36 (2013), pp. 323-328
[27]
J.M. Latour, L.N. Tume.
How to do and report survey studies robustly: A helpful mnemonic SURVEY.
Nurs Crit Care, 26 (2021), pp. 313-314
[28]
M. Raurell-Torredà, R. Fernández-Castillo, M. Rodríguez-Delgado, S. Arias‐Rivera, L. Basco-Prado.
Best practices for iatrogenic anaemia prevention in the intensive care unit: blood-sparing techniques.
[29]
M. Raurell-Torredà, S. Arias-Rivera, M.E. Rodríguez-Delgado, C. Campos-Asensio, R.-J. Fernández-Castillo.
Effectiveness of closed blood sampling systems in intensive care patients: a scoping review.
Enferm Intensiva Engl Ed, 35 (2023), pp. 133-145
[30]
S. Keogh, S. Mathew, A.J. Ullman, C.M. Rickard, F. Coyer.
What blood conservation practices are effective at reducing blood sampling volumes and other clinical sequelae in intensive care? A systematic review.
Aust Crit Care, 36 (2023), pp. 1129-1137
[31]
S. Arias-Rivera, M. Raurell-Torredà, R.-J. Fernández-Castillo, C. Campos-Asensio, I.-J. Thuissard-Vasallo, C. Andreu-Vázquez, et al.
Blood glucose monitoring in critically ill adult patients: type of sample and method of analysis. Systematic review and meta-analysis.
Enferm Intensiva Engl Ed, 35 (2023), pp. 45-72
Copyright © 2024. Sociedad Española de Enfermería Intensiva y Unidades Coronarias (SEEIUC)
asdasdasd
Article options
Tools
Supplemental materials