Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular La biopsia del ganglio centinela en cáncer de mama de más de 3 cm y axila clí...
Información de la revista
Vol. 27. Núm. 3.
Páginas 176-182 (Mayo 2008)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 27. Núm. 3.
Páginas 176-182 (Mayo 2008)
La biopsia del ganglio centinela en cáncer de mama de más de 3 cm y axila clínicamente negativa frente a la indicación estándar T1-T2 < 3 cm
Sentinel node biopsy in T2 breast cancers larger than 3 cm and clinically negative axilla compared with the T1-T2 <3 cm standard indication
Visitas
6287
R. Ruanoa, M. Ramosb, JR. García-Talaveraa, MC. García Macíasc, A. Martín de Arribaa, JM. González-Orúsb, M. Iglesiasb, E. Serranoc
a Servicio de Medicina Nuclear. Hospital Universitario de Salamanca. Salamanca. España.
b Servicio de Cirugía General. Hospital Universitario de Salamanca. Salamanca. España.
c Servicio de Anatomía Patológica. Hospital Universitario de Salamanca. Salamanca. España.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (4)
Tabla 1. CARACTERÍSTICAS CLÍNICAS Y PATOLÓGICAS DE LAS PACIENTES EN LOS GRUPOS DE LESIONES > 3 cm Y < 3 cm
Tabla 2. RESULTADOS DE DETECCIÓN Y NÚMERO DE GANGLIOS CENTINELAS EXTIRPADOS EN LOS GRUPOS A Y B
Tabla 3. RESULTADOS HISTOPATOLÓGICOS DE LOS CASOS CON DETECCIÓN DEL GANGLIO CENTINELA
Tabla 4. CLASIFICACIÓN TUMOR-ADENOPATÍA-METÁSTASIS (TNM) Y ESTADIFICACIÓN DE LAS LESIONES
Mostrar másMostrar menos
Objetivo. Presentar nuestra experiencia en la aplicación de la biopsia del ganglio centinela (GC) en la estadificación axilar del cáncer de mama de más de 3 cm sin evidencia clínica de metástasis. Material y método. Análisis retrospectivo de 393 casos entre enero-2001 y diciembre-2006 divididos en grupos: (A) 47 casos con tumores T2N0 entre 3 y 5 cm, y (B) 346 casos T < 3 cm N0. Empleamos la técnica combinada con 99mTc-sulfuro de renio coloidal y azul de isosulfán. Se realizó una linfogammagrafía preoperatoria y la localización intraoperatoria tuvo lugar con una sonda gammadetectora y con el colorante azul. Se completó la linfadenectomía axilar sólo en el caso de metástasis en el análisis histológico del GC o en ausencia de localización del GC. Resultados. La detección del GC en T2 > 3 cm fue en la gammagrafía del 94 % y con la sonda gammadetectora del 96 %, sin diferencias estadísticamente significativas frente a los T < 3 cm (97 y 98 %). En los T2 > 3 cm la estadificación axilar final fue 45 % pN0, 8 % pN1mi, 34 % pN1a, 11 % pN2a y 2 % pN3a. Existieron diferencias significativas (p < 0,05) al comparar con lesiones < 3 cm palpables y no palpables (62 % pN0 y 74 % pN0 respectivamente). En el seguimiento de los T2 > 3 cm (media 42,88 meses) no encontramos ningún caso con recaída a nivel axilar que pueda considerarse como falso negativo de la técnica. Conclusiones. La detección del GC es posible y segura en tumores de más de 3 cm con axila clínicamente negativa, evitándose en un 45 % de los casos la linfadenectomía axilar, por lo que consideramos que es correcta su inclusión en los criterios de indicación de la técnica en el cáncer de mama.
Palabras clave:
cáncer mama, ganglio centinela, T > 3 cm tumores, estadificación axilar
Objective. To present our experience in the application of sentinel node (SN) biopsy in patients with breast cancer T > 3 cm without clinical evidence of axillary metastasis. Material and Method. Retrospective study of 393 cases in the period 2001-2006, divided into group (A) 47 patients with 3-5 cm T2N0 tumours and group (B) 346 patients T < 3 cm, N0. We employed the combined technique with 99mTc-colloidal rhenium sulphide and isosulfan blue dye. Preoperative lymphoscintigraphy was performed and the SN was located intraoperatively with a gamma ray detection probe and the blue dye. Axillary lymph node dissection was completed only when the SN was positive for metastasis in the histopathology analysis or not located. Results. The SN detection rate for T2 > 3 cm was 94 % in the scintigraphy and 96 % with the probe, with no statistically significant differences between T < 3 cm (97 % and 98 %). In T2 > 3 cm, the final staging was 45 % pN0, 8 % pN1mi, 34 % pN1a, 11 % pN2a and 2 % pN3a. We found statistically significant differences (p < 0.05) when compared with palpable T < 3 cm and non-palpable cancer (62 % pN0 and 74 % pN0, respectively). In the follow-up of T2 > 3 cm (median 42.88 months) we did not find any axillary relapse which could be considered a false negative of the technique. Conclusion. The detection of sentinel lymph nodes is feasible and safe in tumours larger than 3cm with clinically negative axilla. Axillary lymph node dissection can be avoided in 45 % of these patients and therefore, we consider that they should be included as a general indication in breast cancer SN detection.
Keywords:
breast cancer, sentinel node biopsy, T > 3 cm tumours, axillary staging

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos