Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Intensa retención de 99mTc-MIBI en la fase tardía como causa de error diagnós...
Información de la revista
Vol. 29. Núm. 5.
Páginas 251-253 (Septiembre 2010)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 29. Núm. 5.
Páginas 251-253 (Septiembre 2010)
Intensa retención de 99mTc-MIBI en la fase tardía como causa de error diagnóstico en la gammagrafía combinada paratiroides-tiroides
High retention of 99mTc-MIBI in delayed phase as a pitfall in the combined parathyroid-thyroid scintigraphy
Visitas
7812
J.. Verdúa,
Autor para correspondencia
verdu_jos@gva.es

Autor para correspondencia. verdu_jos@gva.es
, C.. Lizárragaa, J.. Clavela, I.. Prataa, J.. Calbob, F.. Pomaresc
a Servicio de Medicina Nuclear, Hospital Universitario de San Juan de Alicante, San Juan de Alicante, Alicante, España
b Servicio de Radiodiagnóstico, Hospital Universitario de San Juan de Alicante, San Juan de Alicante, Alicante, España
c Servicio de Endocrinología, Hospital Universitario de San Juan de Alicante, San Juan de Alicante, Alicante, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos

La gammagrafía de paratiroides con 99mTc-sestaMIBI es muy sensible en el diagnóstico y localización del adenoma de paratiroides. Sin embargo, se pueden producir errores diagnósticos debido a la coexistencia de lesiones tiroideas captantes de MIBI o en pacientes con cirugía tiroidea previa. Para intentar detectar dichas alteraciones tiroideas se realiza una gammagrafía con 99mTc-pertecnetato comparativa el mismo día. Ocasionalmente, como en nuestro caso, la lesión paratiroidea puede presentar una captación inicial y retención tardía de MIBI lo suficientemente importantes como para ser visualizadas en la gammagrafía tiroidea realizada a continuación, dando la falsa apariencia de una lesión captante también de pertecnetato. Este hecho ha sido llamado «shine through». Para evitarlo se pueden realizar las gammagrafías paratiroidea y tiroidea en días distintos. A nosotros nos resultó también de gran utilidad la comparación con ecografía y la PAAF de la lesión con determinación de PTH y tiroglobulina en el líquido aspirado.

Palabras clave:
SestaMIBI
Pertecnetato
Gammagrafía
Paratiroides
Errores

Dual phase parathyroid scintigraphy with 99mTc-sestaMIBI is a very sensitive technique in the preoperative localization and diagnosis of parathyroid adenoma. However, pitfalls have been reported in patients with thyroid nodules with MIBI uptake or with previous thyroid surgery. To solve this problem, a thyroid scintigraphy with 99mTc-pertechnetate is usually performed following the parathyroid study. Occasionally, as in our patient the parathyroid lesion may show high MIBI uptake and delayed washout that interfere with the subsequent thyroid scintigraphy giving the false appearance of a pertechnetate avid lesion. This has been called the «shine through» effect. To avoid it, the parathyroid and thyroid scintigraphies can be performed on separate days. We have also found it useful to compare our results with that of ultrasound and fine needle aspiration puncture with measurement of the parathyroid hormone (PTH) and thyroglobulin in the aspirated material.

Keywords:
SestaMIBI
Pertechnetate
Scintigraphy
Parathyroid
Pitfall

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos