Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Estudio de perfusión miocárdica en pacientes que no alcanzan la frecuencia sub...
Información de la revista
Vol. 27. Núm. 4.
Páginas 259-265 (Julio 2008)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
ePub
Vol. 27. Núm. 4.
Páginas 259-265 (Julio 2008)
DOI: 10.1157/13124635
Estudio de perfusión miocárdica en pacientes que no alcanzan la frecuencia submáxima en la ergometría
Myocardial perfusion study in patients who do not reach submaximal frequency on ergometry
Visitas
...
MV. Gómeza, FG. Gallardoa, M??. San Martínb, R. Perairab, ??. Garcíab, I. Terolb
a Servicio de Medicina Nuclear. Hospital Carlos III. Madrid. Espa??a
b Servicio de Cardiolog??a. Hospital Carlos III. Madrid. Espa??a.
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (5)
Tabla 1. FACTORES DE RIESGO VASCULAR
Tabla 2. DATOS ERGOMÉTRICOS EN FUNCIÓN DE LA FRECUENCIA CARDÍACA ALCANZADA
Tabla 3. DATOS DE LOS PACIENTES EN FUNCIÓN DEL TRATAMIENTO CON BLOQUEADORES BETA
Tabla 4.
Tabla 5.
Mostrar másMostrar menos
El propósito del trabajo fue evaluar la sensibilidad y especificidad de la tomografía computarizada por emisión de fotón único (SPECT) de perfusión miocárdica Tl201 para el diagnóstico de cardiopatía isquémica en el grupo de pacientes con insuficiencia cronotrópica. Material y método. Se seleccionaron exploraciones de 750 pacientes que habían acudido para el diagnóstico de cardiopatía isquémica durante los años 2005-2006. El 28 % (n = 209) no alcanzó la frecuencia submáxima. Mediante encuesta telefónica se recogieron datos acerca del diagnóstico en 112. La ergometría y la SPECT se realizaron según técnica habitual. Resultados. Los pacientes que alcanzaron la frecuencia submáxima y los pacientes con insuficiencia cronotrópica no presentaron diferencias en la edad y el tiempo de ejercicio. La proporción de pacientes en tratamiento con bloqueadores beta, con ergometrías clínicamente positivas y con SPECT patológicos fue mayor en el grupo de los pacientes que no habían alcanzado el 85 % de su frecuencia máxima. Los datos obtenidos en el grupo de pacientes que no alcanzaron la frecuencia submáxima y seguidos mediante encuesta telefónica muestran una sensibilidad de la SPECT del 84 % y una especificidad del 96 %. La sensibilidad de la ergometría fue del 25 % y su especificidad del 96 %. Conclusiones. La ergometría con SPECT de perfusión miocárdica tiene una adecuada sensibilidad y especificidad para el diagnóstico de cardiopatía isquémica aun en pacientes con incompetencia cronotrópica. La proporción de exploraciones patológicas es superior en aquellos pacientes que no se taquicardizaron lo suficiente, lo cual parece indicar que la incapacidad para alcanzar la frecuencia submáxima se relaciona con una mayor probabilidad de presentar cardiopatía isquémica.
Palabras clave:
SPECT miocárdica, ergometría, incompetencia cronotrópica
He aim of the study was to evaluate the sensitivity and specificity of TI-201 myocardial perfusion SPECT for the diagnosis of ischaemic cardiopathy in a group of patients with chronotropic insufficiency. Materials and methods. The examinations of 750 patients who had attended for the diagnosis of ischaemic cardiopathy during 2005-2006 were selected. 28 % (n = 209) did not reach submaximal frequency. Data on the diagnosis was collected in 112 by telephone interview. Ergometry and SPECT were carried out following the usual techniques. Results. Patients who reached submaximal frequency and patients with chronotropic insufficiency did not show differences in age and exercise time. The proportion of patients on beta-blocker treatment, with clinically positive ergometries and pathological SPECT was higher in the patient group which had not reached 85 % of their maximum frequency. The data obtained in the patient group which did not reach submaximal frequency and followed-up by telephone interview showed a SPECT sensitivity of 84 % and specificity of 96 %. The sensitivity of the ergometry was 25 % and its specificity was 96 %. Conclusions. Ergometry with myocardial perfusion SPECT has adequate sensitivity and specificity for the diagnosis of ischaemic cardiopathy, even in patients with chronotropic incompetence. The proportion of pathological examinations is higher in those patients in whom tachycardia could not be sufficiently induced, which seems to indicate that the inability to reach submaximal frequency is related with a higher probability of having ischaemic cardiopathy.
Keywords:
myocardial SPECT, ergometry, chronotropic incompetence

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 22,50 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

es en pt
Política de cookies Cookies policy Política de cookies
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.