metricas
covid
Open Respiratory Archives Positioning of EBUS-guided Cryobiopsy in the Diagnosis of Mediastinal Lesions: A...
Journal Information
Visits
1202
Vol. 7. Issue 3.
(July - September 2025)
Scientific letter
Full text access
Positioning of EBUS-guided Cryobiopsy in the Diagnosis of Mediastinal Lesions: A First Approach
Posicionamiento de la criobioebus para el diagnóstico de lesiones y adenopatías mediastínicas, primera aproximación
Visits
1202
Selene Cuenca Perisa,
Corresponding author
selenecp@gmail.com

Corresponding author.
, Monica Bauzab, Elsie Daviana Meneses Petersenb, Paola Alessandra Benini Padillab, Raquel Martínez Tomása, Andrés Briones Gómeza, Mireya Prieto Rodríguezb, Enrique Cases Viedmaa
a Unidad de Endoscopias Respiratorias y Neumología Intervencionista, Hospital Universitario y Politécnico La Fe, Valencia, Spain
b Department of Pathological Anatomy, Hospital Universitario y Politécnico La Fe, Valencia, Spain
This item has received
Article information
Full Text
Bibliography
Download PDF
Statistics
Figures (1)
Full Text
Dear Editor,

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the principal technique used in the diagnosis of hilar and mediastinal lymph nodes and masses. However, the small sample sizes retrieved make EBUS-TBNA unsuitable for diagnosing some diseases, including lymphoma, rare tumors, granulomatous diseases,1,2 and for re-staging lung tumors. Until now, the choice of technique for obtaining large samples has been EBUS intranodal forceps biopsy (EBUS-IFB)3 or mediastinoscopy. However, a new technique, EBUS-guided transbronchial mediastinal cryobiopsy (EBUS-MCB) that can be used obtain a large sample with same rate of complications as EBUS-TBNA, has recently been introduced.4 The first case report of EBUS-MCB was published in 2019 by Zhang and colleagues, who reported its use in primary mediastinal seminoma.5

To analyze the diagnostic yield of EBUS-MCB versus EBUS-TBNA in the diagnosis of lymphadenopathies and mediastinal lesions, we conducted a single-center, observational, prospective analytical study in the Hospital Universitario y Politécnico La Fe, Valencia, Spain. The study was approved by the Ethics Research Committee in October 2024. We included patients >18 years of age with at least one mediastinal lesion (≥1cm in the short axis) and inadequate rapid on-site evaluation (ROSE) after ultrasound bronchoscopy. Patients with mediastinal cysts or abscesses and/or contraindications to endoscopy or mediastinal biopsy were excluded. We used Student's t test (statistical p-value <0.05) to analyze differences between cellularity, and designed an algorithm to position EBUS-MCB in the diagnosis of these lesions.

In all patients, an EBUS-MCB procedure was performed by an experienced bronchoscopist under conscious sedation using a convex probe ultrasound bronchoscope (BFUC180F; Olympus Medical systems, Japan). First, 3 passes of the nodes were made using a conventional EBUS-TBNA needle (19 G Vizishot 2 flex TBNA needle; NA-U403SX-4019). Our hospital performs about 100 EBUS-TBNAs per year. In all cases, ROSE of aspirated material was performed by an expert cytopathologist. Patients in whom ROSE did not yield a diagnosis or the sample was considered of inadequate quality (inadequate ROSE), cryobiopsy of the largest lymph node was performed, generally consisting of 3 cryobiopsies with a 1.1mm cryoprobe and a freezing time of 7s.

A total of 36 patients were enrolled. The mean age of participants was 54.6 years. Most of the lesions were lymphadenopathy located in mediastinal station 7 (n=13), 4R (n=6) and hilar lymphadenopathies 11L (n=4). Other stations were 2R (n=1), 4L (n=2) and 3p (n=2), 12R (n=1), 11R (n=2), and 10R (n=1). In 4 patients, we biopsied 2 stations, 4R+7 (n=1) and 7+11L (n=3). Most histopathological diagnoses were lung tumors (non-small cell lung cancer, predominantly adenocarcinoma, small cell lung cancer, and large cell neuroendocrine carcinoma) followed by granulomatous diseases. In 4 patients, the diagnosis was reached with EBUS-MCB only (lymphoma, arterial sarcoma, undifferentiated tumor, and small cell lung cancer). Samples were diagnostic in 80.5% of EBUS-TBNA procedures and 91.6% of EBUS-MCB procedures. Samples obtained by EBUS-MCB had higher cellularity than those obtained by EBUS-TBNA (p-value: 0.008). The most common adverse event observed was minor (5.5%) and medium bleeding (2.7%). No major complications were noted during the procedure. Only one (2.7%) patient presented persistent cough during the procedure.

EBUS-MCB is a new reality. Different sizes of needles have been used – 19G, 21G and 22G – and no differences have been observed among needle sizes. Freezing time is another controversy. The differences between centers range from 3s to 10s. Recently, Ariza-Prota et al.7 published a study that aimed to standardize the EBUS-MCB procedure. Similarly to these authors, we use a 19G needle to create the pathway through which we introduce the 1.1mm cryoprobe and freeze for 7s.6,7 Finally, the number of cryobiopsies varies among centers with a range of 1–5 cryobiopsies. To date, the number of samples recommended for obtaining the highest number of diagnoses with the lowest number of complications has not been described. In our hospital, we perform 2–3.6

EBUS-MCB has a good safety profile. Only mild complications, normally mild/moderate bleeding resolved during the procedure, have been described in the literature.8,9 Yang et al.8 reported that diagnosis was achieved in 47.7% of cases without severe complications, concluding that EBUS-MCB is safe and effective.

The quality of the sample obtained with EBUS-MCB is much better than that obtained with EBUS-TBNA, thus improving the number of positive diagnoses.10 Specifically, we described statistical differences between cellularity in EBUS-MCB vs EBUS-TBNA. In our experience, we needed EBUS-MCB to diagnosis rare tumors, such as arterial sarcoma and undifferentiated tumor. Diagnosis of lymphoma has also been found to be greater with EBUS-MCB, allowing its characterization in >80% of cases.7 In our case, the diagnosis of lymphoma was higher using EBUS-MCB (5.4% vs 2.7%), obviating the need for further diagnostic studies. For granulomatous diseases (sarcoidosis, tuberculosis, etc.), better results with EBUS-MCB have been reported in the literature,7 although our results were the same for both EBUS-TBNA and EBUS-MCB.

Despite the support in the literature for the use of EBUS-MCB in obtaining histological samples, there are insufficient studies evaluating the cost-effectiveness of cryobiopsy in all EBUS cases. To its disadvantage, EBUS-MCB needs more equipment (a cryomachine, cryogen, and 1.1-mm disposable cryoprobes), and the intervention lasts approximately 2min more than EBUS-TBNA. The great advantage, though, is that it obtains larger samples. This is useful for reducing the diagnostic delay, especially in lymphoma where it avoids the need for further diagnostic studies,11 for performing cancer molecular tests,12 and for diagnosing rare disorders.13 A recently published metanalysis found that EBUS-MCB improves tissue acquisition in mediastinal lesions (92% EBUS-MCB vs 81% EBUS-TBNA) and similar adverse event risks.9

As suggested in the literature, further studies are needed to evaluate uncertainties in the selection of suitable cases for EBUS-MCB, and optimal patient selection criteria remain to be defined.12,14 For this reason, we propose an algorithm (Fig. 1) for the conduct of EBUS-MCB in patients with an inadequate ROSE, in clinical trials, and in the case of suspected lymphoma, rare tumors, or tumor re-staging.5,15

Fig. 1.

Algorithm to perform EBUS-MCB for undiagnosed mediastinal lesions and lymphadenopathies. EBUS-MCB: endobronchial ultrasound-guided mediastinal cryobiopsy; EBUS-TBNA: endobronchial ultrasound-guided transbronchial needle aspiration; ROSE: rapid on-site evaluation. *In case of clinical trial, perform EBUS-MCB.

Our study has some limitations. This is a single-center study performed over a 1-year period in only 37 patients. The results of the study need to be replicated in other centers, and larger studies are needed before EBUS-MCB can be definitively included in the algorithm for the study of mediastinal lesions.

To conclude, EBUS-MCB is a novel technique for performing biopsies of mediastinal tumors and lymph nodes. It is useful for obtaining large samples with a higher percentage of cellularity than those retrieved with EBUS-TBNA, but with a similar rate of complications. This algorithm represents the initial phase in the establishment of standardized guidelines for the application of this novel technique.

Funding

No funding was received.

Authors’ contributions

Selene Cuenca Peris contributed to the literature search, study design, data interpretation, and performed EBUS. Elsie Daviana Meneses Petersen contributed to data recollection.

Raquel Martínez Tomás, Andrés Briones Gómez and Enrique Cases Viedma performed EBUS.

Monica Bauza and Mireya Prieto Rodríguez analyzed all samples, and P. Alessandra Benini Padilla collected all pathology data.

Conflicts of interest

The results presented have not been previously published. The authors declare no competing interests.

References
[1]
H.B. Grosu, M. Iliesiu, N.P. Caraway, L.J. Medeiros, X. Lei, C.A. Jimenez, et al.
Endobronchial ultrasound-guided transbronchial needle aspiration for the diagnosis and subtyping of lymphoma.
Ann Am Thorac Soc, 12 (2015), pp. 1336-1344
[2]
V. Muthu, N. Gupta, S. Dhooria, I.S. Sehgal, K.T. Prasad, A.N. Aggarwal, et al.
Role of cytomorphology in differentiating sarcoidosis and tuberculosis in subjects undergoing endobronchial ultrasound-guided transbronchial needle aspiration.
Sarcoidosis Vasc Diffus lung Dis, 36 (2019), pp. 209-216
[3]
G. Cheng, A. Mahajan, S. Oh, S. Benzaquen, A. Chen.
Endobronchial ultrasound-guided intranodal forceps biopsy (EBUS-IFB)-technical review.
J Thorac Dis [Internet]., 11 (2019), pp. 4049-4058
[4]
J. Zhang, J.R. Guo, Z.S. Huang, W.L. Fu, X.L. Wu, N. Wu, et al.
Transbronchial Transbronchial mediastinal cryobiopsy in the diagnosis of mediastinal lesions: a randomised trial.
Eur Respir J, 58 (2021), pp. 2100055
[5]
J. Zhang, W.L. Fu, Z.S. Huang, J.R. Guo, Q. Li, F.J.F. Herth, et al.
Primary mediastinal seminoma achieved by transbronchial mediastinal cryobiopsy.
Respiration, 99 (2020), pp. 426-430
[6]
M.A. Ariza Prota, J. Pérez Pallarés, E. Barisione, S. Onyancha, N. Corcione, H.E. Torres Rivas, et al.
Proposal for a standardized methodology for performing endobronchial ultrasound-guided mediastinal cryobiopsy: a four-step approach.
Mediastinum, 8 (2024), pp. 30
[7]
M. Ariza-Prota, J. Pérez-Pallarés, A. Fernández-Fernández, L. García-Alfonso, J.A. Cascón, H. Torres-Rivas, et al.
Endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy in the diagnosis of mediastinal lesions: safety, feasibility and diagnostic yield – experience in 50 cases.
ERJ Open Res, 9 (2023), pp. 00448-2022
[8]
L. Yang, S. Bi, G. Wei, D. Yu, H. Wang, J. Dong, et al.
The efficacy and safety of radial endobronchial ultrasound-guided transbronchial lung cryobiopsy in the diagnosis of lung disease.
J Thorac Dis, 15 (2023), pp. 6570-6578
[9]
P.S. Chandragiri, A. Tayal, S. Mittal, N.K. Madan, P. Tiwari, V. Hadda, et al.
Utility and safety of endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy (EBUS-TMC): a systematic review and meta-analysis.
[10]
A. Yu Lee-Mateus, J.C. Garcia-Saucedo, D. Abia-Trujillo, G. Labarca, N.M. Patel, J.M. Pascual, et al.
Comparing diagnostic sensitivity of different needle sizes for lymph nodes suspected of lung cancer in endobronchial ultrasound transbronchial needle aspiration: systematic review and meta-analysis.
Clin Respir J, 15 (2021), pp. 1328-1336
[11]
N.C. Huan, W.L. Lee, H.Y. Ramarmuty, L.E. Nyanti, M.S.L. Tsen, D. Yunus.
The utility of endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy (EBUS-TBMC) for the diagnosis of mediastinal lymphoma.
Respirol Case Rep, 12 (2024), pp. e01342
[12]
H.Y. Ramarmuty, M. Oki.
Endobronchial ultrasound-guided transbronchial mediastinal cryobiopsy: a narrative review.
Mediastinum, 8 (2024),
[13]
T. Calari, S. Petrarulo, A. Dubini, S. Piciucchi, C. Ravaglia, V. Poletti.
Endobronchial ultrasound-guided cryobiopsy for diagnosing a case of granulomatosis with polyangiitis.
Respirol Case Rep, 12 (2024),
[14]
M. Botana-Rial, I. Lojo-Rodríguez, V. Leiro-Fernández, C. Ramos-Hernández, A. González-Montaos, L. Pazos-Area, et al.
Is the diagnostic yield of mediastinal lymph node cryobiopsy (cryoEBUS) better for diagnosing mediastinal node involvement compared to endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA)? A systematic review.
Respir Med, 218 (2023), pp. 107389
[15]
V.N. Maturu, V.P. Prasad, C.R. Vaddepally, R.R. Dommata, S. Sethi.
Endobronchial ultrasound-guided mediastinal lymph nodal cryobiopsy in patients with nondiagnostic/inadequate rapid on-site evaluation: a new step in the diagnostic algorithm.
J Bronchology Interv Pulmonol, 31 (2024), pp. 2-12
Copyright © 2025. Sociedad Española de Neumología y Cirugía Torácica (SEPAR)
Download PDF
Article options
Tools