Buscar en
Fisioterapia
Toda la web
Inicio Fisioterapia Fiabilidad intrasesión en la exploración del equilibrio mediante plataforma de...
Información de la revista
Vol. 33. Núm. 5.
Páginas 192-197 (Septiembre - Octubre 2011)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
3497
Vol. 33. Núm. 5.
Páginas 192-197 (Septiembre - Octubre 2011)
Original
Fiabilidad intrasesión en la exploración del equilibrio mediante plataforma de presión
Intrasession reliability of balance studies by means of a pressure platform
Visitas
3497
J.C. Zuil Escobar
Autor para correspondencia
jczuil@ceu.es

Autor para correspondencia.
, C.B. Martínez Cepa
Departamento de Fisioterapia, Facultad de Medicina, Universidad CEU-San Pablo, Madrid, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (1)
Tablas (3)
Tabla 1. Características de las variables demográficas (n = 70)
Tabla 2. CCI e IC del 95% para el CCI de todos los tiempos estudiados*
Tabla 3. Variables de la estabilometría
Mostrar másMostrar menos
Resumen
Objetivo

El objetivo del presente estudio ha sido evaluar la fiabilidad intrasesión de la exploración del equilibrio por medio de plataforma de presión, empleando distintos tiempos en la duración de la prueba.

Material y métodos

Se ha realizado un estudio de fiabilidad, prospectivo, utilizando una muestra de 70 sujetos sanos (18-35 años). Los sujetos fueron explorados utilizando una plataforma de presión, empleando dos pruebas para cada uno de los cuatro tiempos seleccionados: 5, 15, 30 y 60 s. Dentro de las variables estabilométricas, se recogieron la superficie del baricentro y los desplazamientos de este en sentido antero-posterior y lateral. Para evaluar la fiabilidad de dichas variables, se emplearon coeficientes de correlación intraclase.

Resultados

El tiempo de 60 s ha mostrado los coeficientes de correlación más altos (0,544-0,650). Tanto para los 60 s como para los 30 s, los coeficientes de correlación han mostrado un nivel de fiabilidad moderado. En el tiempo de 15 s, la fiabilidad ha sido pobre, mientras que en el tiempo de 5 s no se pudieron calcular porque las variables no presentaban una distribución normal.

Conclusiones

El nivel de fiabilidad para la exploración del equilibrio mediante plataforma de presión aumenta a medida que lo hace el tiempo de duración de la prueba.

Palabras clave:
Equilibrio
Fiabilidad
Abstract
Aim

The aim of the present study has been to evaluate the intrasession reliability of balance exploration by means of a pressure platform using different times along the duration of the test.

Materials and methods

Reliability and prospective study has been made using a sample of 70 healthy individuals aged 18 to 35 years old. Each individual was explored using a pressure platform and two test for each of the four selected times: 5, 15, 30 and 60seconds. Among the studied stabilometric parameters, the center of pressure surface and its movements in anteroposterior and lateral direction. Interrelated correlation coefficient was used to evaluate the reliability of the mentioned parameters.

Results

The time of 60seconds has showed the highest interrelated correlation coefficient (0,544-0,650). The interrelated correlation coefficient has showed a moderate reliability for the time of 60 and 30seconds. The time of 15seconds has showed a poor reliability while the five seconds time was not used due to the impossibility of its calculation because of the abnormal distribution of the parameters.

Conclusion

The level of reliability for the balance exploration using a pressure platform increases as well as the duration of the test goes up.

Keywords:
Postural balance
Reliability

Artículo

Opciones para acceder a los textos completos de la publicación Fisioterapia
Socio
Socios AEF

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Problemas con el acceso de socios AEF
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
E-mail
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Fisioterapia

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.ft.2023.03.101
No mostrar más