Buscar en
Fisioterapia
Toda la web
Inicio Fisioterapia Fiabilidad intraexaminador e interexaminador de Clinometer para medir el rango d...
Información de la revista
Vol. 45. Núm. 1.
Páginas 13-19 (Enero - Febrero 2023)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
19
Vol. 45. Núm. 1.
Páginas 13-19 (Enero - Febrero 2023)
Original
Fiabilidad intraexaminador e interexaminador de Clinometer para medir el rango de movimiento en pacientes con artrosis de cadera
Test–retest and inter-rater reliability of Clinometer for measuring range of motion in patients with hip osteoarthritis
Visitas
19
L. Ceballos-Laita
Autor para correspondencia
luis.ceballos@uva.es

Autor para correspondencia.
, M.T. Mingo-Gómez, R. Medrano-de-la-Fuente, I. Hernando-Garijo, S. Jiménez-de-Barrio
Grupo de Investigación Clínica en Ciencias de la Salud, Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Ciencias de la Salud. Universidad de Valladolid, Soria, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (1)
Resumen
Objetivo

Evaluar la fiabilidad intraexaminador e interexaminador de la aplicación Clinometer para medir el rango de movimiento (RDM) de la cadera en pacientes con artrosis de cadera y su correlación con el goniómetro universal.

Métodos

Se diseñó un estudio de medidas repetidas en el que se incluyeron 35 pacientes con artrosis de cadera. Se registró el RDM de rotación interna, externa, flexión y extensión de cadera mediante la aplicación Clinometer por 2 examinadores independientes. Se calculó la fiabilidad intraexaminador e interexaminador utilizando el coeficiente de correlación intraclase, y se calculó el error estándar de medición y el cambio mínimo detectable. Se utilizó el coeficiente de correlación de Pearson para correlacionar la aplicación Clinometer con el goniómetro universal.

Resultados

La aplicación Clinometer mostró una fiabilidad excelente tanto intraexaminador (coeficiente de correlación intraclase: 0,82-0,96) como interexaminador (coeficiente de correlación intraclase: 0,81-0,95) para todos los RDM de la cadera valorados. La correlación entre este instrumento y el goniómetro universal mostró ser fuerte para todos los RDM de la cadera (r>0,70).

Conclusión

La aplicación Clinometer ha mostrado unos niveles de fiabilidad excelentes para la medición del RDM de rotación interna, externa, flexión y extensión de la cadera en pacientes con artrosis y presenta una fuerte correlación con el goniómetro universal.

Palabras clave:
Artrosis de cadera
Rango de movimiento
Aplicación móvil
Abstract
Objective

To evaluate the test–retest and inter-rater reliability of the application Clinometer for measuring the hip range of motion (ROM) in patients with hip osteoarthritis and its correlation with the universal goniometer.

Methods

A blinded repeated measured was carried out with 35 patients with hip osteoarthritis. Hip internal rotation, external rotation, flexion and extension ROM were measured using Clinometer app by 2 independents raters. The intraclass correlation coefficient was used to calculate the test–retest reliability and inter-rater reliability. The standard error measurement and minimal detectable change were also calculated. The Pearson's correlation coefficient was used to correlate the app with the universal goniometer.

Results

Clinometer application achieved excellent test–retest reliability (intraclass correlation coefficient: 0.82-0.96) and inter-rater reliability (intraclass correlation coefficient: 0.81-0.95) in all the ROMs assessed. The correlation analysis with the universal goniometer showed strong correlation values (r>0.70) in all the ROMs assessed.

Conclusion

Clinometer application presented excellent test–retest reliability and inter-rater reliability for the measurement of hip ROM in patients with hip osteoarthritis. The smartphone application showed a strong correlation compared to universal goniometer.

Keywords:
Hip osteoarthritis
Range of motion
Mobile applications

Artículo

Opciones para acceder a los textos completos de la publicación Fisioterapia
Socio
Socios AEF

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Problemas con el acceso de socios AEF
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
E-mail
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Fisioterapia

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos