Resultados de un programa de detección precoz de la hipoacusia neonatal
Results of an early hearing detection program
Visitas
4890
Silvia A. Borkoski Barreiro, Juan C. Falcón González, Jorge Bueno Yanes
Autor para correspondencia
fambuya@hotmail.com

Autor para correspondencia.
, José L. Pérez Bermúdez, Zoraida López Cano, Ángel Ramos Macías
Unidad de Hipoacusia-Programa de Implantes Cocleares, Servicio de Otorrinolaringología, Complejo Hospitalario Universitario Insular-Materno Infantil, Las Palmas de Gran Canaria, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Resumen
Introducción y objetivos

La hipoacusia neonatal es un problema de salud pública, que cumple los requisitos para ser sometido a cribado universal. El objetivo de este artículo es analizar los resultados obtenidos en el programa de detección precoz de la hipoacusia implementado en nuestro centro desde enero de 2007 hasta diciembre de 2010.

Métodos

Se estudiaron 26.717 recién nacidos mediante otoemisiones acústicas transitorias (OEAT) en la fase de cribado auditivo. La etapa diagnóstica fue llevada a cabo en la unidad de hipoacusia del servicio.

Resultados

En el período entre enero de 2007 y diciembre de 2010 nacieron 27.935 niños. Se practicó el screening a 26.717, de los cuales 24.173 presentaron OEAT positivas, 1.040 tuvieron OEAT ausentes y 1.504 presentaron OEAT en un oído estando ausentes en el oído contralateral. Presentaron factores de riesgo asociado para hipoacusia 4.674 recién nacidos. En una segunda fase del programa se practicó OEAT a 5.156 niños, de los cuales 4.626 presentaron otoemisiones positivas en ambos oídos, 323 no presentaron otoemisiones en un oído y 207 no pasaron esta segunda fase. Fueron derivados a potenciales evocados auditivos de tronco cerebral (PEATC) un 3,8% del total de niños estudiados. Veintiséis niños ingresaron al programa de implantes cocleares. Nuestro programa de detección precoz de la hipoacusia alcanzó una cobertura del 95,64%.

Conclusiones

El programa de detección precoz de la hipoacusia de nuestro complejo es adecuado a nuestro funcionamiento, alcanzando una cobertura del 95,64% considerándose muy positiva la relación existente entre eficacia y eficiencia.

Palabras clave:
Hipoacusia neonatal
Detección precoz
Sordera
Abstract
Introduction and objectives

Neonatal hearing loss is a public health problem that meets the requirements for submission to universal screening. Our objective was to analyse the results of the early hearing detection and intervention program implemented at our centre between January 2007 and December 2010.

Methods

We studied 26,717 newborns during the period mentioned, using transient otoacoustic emissions (TOAEs) for the screening. The diagnostic phase was carried out at the hearing loss department.

Results

In our area, there were 27,935 births between January 2007 and December 2010. The screening was performed on 26,717 children. Of these, 24,173 had positive TOAEs, 1,040 had no TOAEs and 1,504 presented TOAEs in 1 ear with absence of TOAEs in the contralateral ear. Risk factors associated with hearing loss were found in 4,674 infants. In a second phase of the program, TOAEs were given to 5,156 children, of whom 4,626 had positive otoacoustic emissions in both ears, 323 had no TOAEs in 1 ear and 207 failed this second phase. Of all children studied, 3.8% were referred to auditory brainstem response (ABR) testing and 26 children entered the cochlear implant program. The program reached coverage of 95.64%.

Conclusions

The early hearing detection and intervention program at our hospital is suitable for our environment, reaching 95.64% of coverage. We consider the relationship between effectiveness and efficiency to be positive.

Keywords:
Neonatal hearing loss
Early detection
Deafness

Artículo

Opciones para acceder a los textos completos de la publicación Acta Otorrinolaringológica Española
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Acta Otorrinolaringológica Española

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos