metricas
covid
Revista Española de Cirugía Ortopédica y Traumatología Arthroscopic rotator cuff repair using a single or double row technique: A meta...
Información de la revista
Vol. 69. Núm. 6.
Páginas T659-T669 (Noviembre - Diciembre 2025)
Visitas
1366
Vol. 69. Núm. 6.
Páginas T659-T669 (Noviembre - Diciembre 2025)
Review article
Acceso a texto completo
Arthroscopic rotator cuff repair using a single or double row technique: A meta-analysis of randomized clinical trial
Reparación artroscópica del manguito rotador mediante una técnica de hilera simple o doble hilera: un metaanálisis de los ensayos clínicos aleatorizados
Visitas
1366
J.H. Núñeza,b,
Autor para correspondencia
hassan2803med@gmail.com

Corresponding author.
, J.D. Montenegrob, M. Surrocab, B. Ocrospoma-Floresa, E. Guerra-Farfána, G. Mendez-Sancheza, A. Fraguasa, O. Gómeza
a Arthoesport, Cirugía Ortopédica y Traumatología, Centro Médico Teknon, Grupo Quirón Salud, Barcelona, Spain
b Cirugía Ortopédica y Traumatología, Universitat de Barcelona; Hospital Universitario Mútua de Terrassa, Terrassa, Barcelona, Spain
Contenido relacionado
J.H. Núñez, J.D. Montenegro, M. Surroca, B. Ocrospoma-Flores, E. Guerra-Farfán, G. Mendez-Sanchez, A. Fraguas, O. Gómez
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (5)
Mostrar másMostrar menos
Tablas (2)
Table 1. Summary of the studies included in this systematic review.
Tablas
Tablas
Mostrar másMostrar menos
Abstract
Purpose

To compare the double row technique versus the single row technique for arthroscopic rotator cuff repair, in order to assess whether there are clinical differences.

Methods

Systematic review of randomized clinical trials comparing the clinical results of the double-row technique versus the single-row technique in arthroscopic rotator cuff repair. Demographic, clinical, and surgical variables were analyzed, including functional scores, tendon healing rate, and re-tear rate.

Results

Thirteen randomized clinical trials were selected. 437 patients in the single row group (50.7%) and 424 patients in the double row group (49.3%) were analyzed. No significant differences were found between the two groups in terms of age (P = .84), sex (P=.23) and loss to follow-up (P=.52). Significant differences were found for the better results of the double row technique at the UCLA level (P=.01). No significant differences were found on the Constant-Murley scale (P=.87) or on the ASES scale (P=.56). Similarly, there was a higher healing rate (P=.006) and less risk of rotator cuff re-tears with the double row technique (P=.006).

Conclusions

In rotator cuff repair, the double row technique was found to be superior to the single row technique in terms of better UCLA score, better tendon healing rate, and lower re-tear rate. No clinically significant differences were found on the Constant-Murley scale or on the ASES scale.

Keywords:
Shoulder
Rotator cuff
Single row
Double row, Systematic review
Resumen
Objetivo

Comparar la técnica doble hilera versus la técnica de hilera simple para la reparación artroscópica del manguito rotador, con el fin de valorar si hay diferencias clínicas, funcionales y radiológicas.

Métodos

Revisión sistemática de ensayos clínicos aleatorizados que comparen los resultados clínicos de la técnica doble hilera versus la técnica de hilera simple en la reparación artroscópica del manguito rotador. Se analizaron las variables demográficas, clínicas y quirúrgicas, incluyendo escalas funcionales, tasa de curación del tendón y tasa de re-rupturas.

Resultados

Trece ensayos clínicos aleatorizados fueron seleccionados. Se analizaron 437 pacientes en el grupo de hilera simple (50,7%) y 424 pacientes en el grupo de doble hilera (49,3%). No se encontraron diferencias significativas entre ambos grupos en lo referente a la edad (p=0,84), sexo (p=0,23) y pérdidas durante el seguimiento (p=0,52). La técnica de doble hilera obtuvo mejores resultados en la escala UCLA, siendo esta diferencia estadísticamente significativa (p=0,01). No se encontraron diferencias significativas en la escala Constant-Murley (p=0,87) ni en la escala ASES (p=0,56). Del mismo modo, hubo una mayor tasa de curación (p=0,006) y menor tasa de re-rupturas del manguito rotador con la técnica de doble hilera (p=0,006).

Conclusiones

En la reparación del manguito rotador se halló que la técnica doble hilera es superior a la técnica hilera simple en términos de una mejor puntuación en la escala UCLA, una mejor tasa de curación del tendón y una menor tasa de re-rupturas. No se encontraron diferencias significativas a nivel clínico en la escala Constant-Murley ni en la escala de ASES.

Palabras clave:
Hombro
Manguito rotador
Hilera simple
Doble hilera, Revisión sistemática
Texto completo
Introduction

Arthroscopic repair of rotator cuff tears is a common procedure that offers advantages over open surgery which include: a minimally invasive approach, smaller skin incisions, absence of deltoid detachment, and less soft tissue dissection.1 Ideally, rotator cuff repair should provide stable fixation and minimise gap formation between the tendon and bone during the healing process.2 The single-row technique for rotator cuff tear repair has been the standard technique, although numerous studies have reported a higher rate of re-tears and incomplete tendon healing.3,4 The re-tear rate with the single-row technique ranges from 25.9% to 56%, whereas the re-tear rate with the double row technique ranges from 14.2% to 27%.4,5 One possible explanation for the high rate of repair site failure is that the single-row technique does not fully recreate the native tendon footprint insertion on the greater tuberosity, leading to incomplete anatomical healing.3,5 It is estimated that with the single-row technique, an average of 52.7% of the rotator cuff footprint remains uncovered.3

The double row technique has been advocated as a means of increasing the contact area between the rotator cuff and the bone bed. Theoretically, this technique incorporates medial and lateral anchors, which increases the initial coverage of the tendon–bone junction.6 Restoring the anatomical footprint may improve healing of the tendon–bone interface and the mechanical strength of repaired tendons.7 Good clinical outcomes have been published for arthroscopic rotator cuff repair using a double row technique.8,9 Several studies have also reported anatomical and biomechanical advantages of the technique compared with the single-row technique.7–9 The results of these studies indicate that the double row technique provides a better healing environment for the tendon and bone for rotator cuff repairs than the single-row technique.2,10–12 However, there are also studies indicating no clinical differences in postoperative outcomes between the two techniques.13,14 Currently, there is still controversy regarding which of the two techniques offers better results in rotator cuff repair. With the hypothesis that the double row technique presents better functional outcomes and a lower re-tear rate, the primary objective of this study was to compare the double row technique versus the single-row technique for rotator cuff repair through a systematic review of randomised clinical trials.

Materials and methodsSystematic review

This meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Statement,15 and the systematic review followed the recommendations of the Cochrane Handbook for Systematic Reviews of Interventions.16 The electronic search was conducted between July and September 2022. Studies published up to September 15, 2022, that evaluated clinical and radiological outcomes in patients undergoing rotator cuff repair using the single-row or double row technique were sought. The search terms used in English were: 1. Rotator cuff repair, 2. Single-Row, 3. Double row, 4. Randomised Controlled Trials (RCT).

Inclusion and exclusion criteria

The inclusion criteria for the studies were as follows: (1) studies published between 2000 and 2022; (2) randomised clinical trials (RCTs) comparing the two surgical procedures (single-row technique or double row technique) (Fig. 1); (3) studies with a minimum follow-up of 12 months, and (4) studies that report at least one outcome related to the variables studied. Studies with the following were excluded from the meta-analysis: (1) lack of comparative data; (2) biomechanical or in vitro studies; (3) papers that do not present their results through means with standard deviations; (4) studies with duplicate data, and (5) conference presentations, editorials, and abstracts.

Figure 1.

(a) Illustration and arthroscopic image of single-row repair. (b) Arthroscopic illustration and image of the repair using a double row technique.

Study selection

The titles and abstracts of the articles found through the systematic search were evaluated, and relevant studies were selected for a full review. If the abstract did not provide sufficient data to determine the eligibility, the full article was reviewed. References were also cross-referenced to identify papers potentially missed by the electronic search. When analysing and organising the studies, the country and city of the hospital or institution where the surgical interventions were performed, the name of the surgeon in the studies, and the evaluation period were verified to identify duplicate patient cohorts. If the same patient cohort was evaluated in more than one study, the last study with the longest follow-up period was included, while the others were excluded.

Following PRISMA guidelines, two independent reviewers (J.D.M. and M.S.) evaluated titles, abstracts, and full-text articles. If there was a debate about the inclusion of an article, a third independent reviewer (J.H.N.) was consulted.

Data extraction: variables analysed

Data were extracted from the main texts and supplementary appendices. Two researchers independently extracted data from the studies included in the final analysis. A predefined data extraction form was used for data extraction. Any unresolved disagreements between the two researchers were reviewed by a third researcher (J.H.N.).

The data obtained were divided as follows: (I) General characteristics, including first author, year of publication, clinical trial number (NCT), included patients, age, sex, suture type (single-row or double row), follow-up time, and loss to follow-up. (II) Postoperative clinical variables collected included the American Shoulder and Elbow Surgeons (ASES) score, the Constant-Murley Shoulder Score, and the University of California, Los Angeles (UCLA) score. (III) Finally, tendon healing and re-rupture rates after surgery were recorded, which were measured by postoperative ultrasound or MRI at the end of follow-up.

Quality assessment

The quality of the RCTs was assessed using Review Manager (RevMan) software version 5.3 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, 2014) to assess the risk of bias. The assessment methods consisted of the following steps: random sequence generation, concealed allocation, assessment of blinding, incomplete outcome data, and selective reporting of results. Scores in these domains are translated into an overall assessment of the overall risk of bias for a given RCT: (I) “low risk of bias”; (II) “unclear risk of bias”; or (III) “high risk of bias.”

Statistical analysis

Descriptive statistics were mean and SD for continuous variables and count and percentage for categorical variables. The meta-analysis was performed using the Cochrane Community Review Manager software (version 5.3). For binary variables, the odds ratio (OR) was used for assessment, while for continuous variables, the standard mean difference (SMD) with a 95% confidence interval (CI) was applied. Study heterogeneity was estimated using the I2 test. The random-effects inverse variance model was applied. Statistical significance was defined as a p value <.05.

ResultsReview of the literature

The initial search returned a total of 135 studies, of which 111 were excluded from the present systematic review after reading the title and/or abstract. Of the remaining 24 studies, and after reviewing the full text, 11 were excluded, leaving 13 RCTs for inclusion in the final analysis17–29 (Fig. 2). Fig. 3 provides a summary of the risk of bias.

Figure 2.

Flowchart for the identification and selection of studies included in this systematic review.

Figure 3.

Risk of bias summary. Green indicates “low risk of bias,” red indicates “high risk of bias,” and yellow indicates “unclear risk of bias.”

Study characteristics

The characteristics of each study are contained in Table 1. The meta-analysis included a total of 1139 patients. However, at the end of follow-up for the final analysis, 24.4% (278 patients) were lost. No statistically significant differences were found in patient loss to follow-up (OR: 1.16; 95% CI: .74–1.83; p=.52) with no heterogeneity (I=.0%; p=.94).17–29

Table 1.

Summary of the studies included in this systematic review.

Study  Year  Number of patientsType of DR  Age (mean)Follow-up (months  Follow-up scales 
    SR  DR    SR  DR     
Imam et al.  2020  40  40  Transosseous equivalent  61.6  60  36  UCLA and Constant scale 
Yamakado et al.  2019  53  53  Transosseous equivalent  65.8  65.4  28.6  UCLA scale 
Barber et al.  2016  20  20  Transosseous equivalent  57  55  27  Constant and ASES 
Franceschi et al.  2016  30  28  Double row suture  61.8  58.9  26.8  UCLA scale 
Nicholas et al.  2016  25  24  Transosseous equivalent  61  65  26  ASES scale 
Carbonel et al.  2012  80  80  Double row suture  60.8  61.6  33.5  UCLA, Constant and ASES scales 
Lapner et al.  2012  48  42  Double row suture  56  57.8  24  Constant and ASES scales 
Ma et al.  2012  80  80  Double row suture  55.79  55.21  24  UCLA and ASES scales 
Khon et al.  2011  31  31  Double row suture  61.6  61.1  32.8  UCLA, Constant and ASES scales 
Aydin et al.  2010  34  34  Transosseous equivalent  59  57  36  Constant scale 
Burkus et al.  2009  20  20  Transosseous equivalent  56  57  12  UCLA, Constant and ASES scales 
Grasso et al.  2009  40  40  Transosseous equivalent  58.3  55.2  24.8  Constant scale 
Franceschi et al.  2007  30  30  Double row suture  63.5  59.6  22.5  UCLA scale 

ASES: American Shoulder and Elbow Surgeons; Constant: Constant-Murley scale; DR: double row; SR: single row; UCLA: Universidad of California in Los Angeles.

A total of 437 patients in the single-row group (50.7%) and 424 patients in the double row group (49.3%) were analysed. The mean age was 59.9 years (SD: 3.1) in the single-row group and 59.1 years (SD: 3.6) in the double row group. There were no statistically significant differences between the two groups (SMD: 0.02; 95% CI: −.22 to .27; p=0.84).8,20,24,25,27,28 No statistically significant differences were found regarding patient gender (OR: .83; 95% CI: .61–1.13; p=.23). Appendix A shows variables studied in the articles analysed, such as the types of rupture, the number of tendons involved, the size of the rupture, and fatty atrophy. No article reported statistically significant differences between the two groups for these variables.

Clinical results

The most frequently used scales were the UCLA scale, the Constant-Murley scale, and the ASES scale.17–21 Four studies used at least two of these functional scales,17,18,26,27 and three studies used all three (Table 1). Significant differences in outcomes were found with the double row technique for the UCLA scale (SMD: .22; 95% CI: .05–.38; p=.01), with no heterogeneity (I=00%; p=.89).17–19,21,23,25,26,28 (Fig. 4a) However, no significant differences were found at the Constant-Murley scale level (SMD: −.02; 95% CI: −0.21 to .18; p=.87) with mild heterogeneity (I2=32%; p=.16),17,19,20,22,25,27–29 (Fig. 4b) nor at the ASES scale level (SMD: .05; 95% CI: −.13 to .24; p=.56) with zero heterogeneity (I2=0%; p=.48)19,22,24–28 (Fig. 4c).

Figure 4.

(a) Forest plot of the UCLA (University of California, Los Angeles) scale. (b) Forest plot of the Constant-Murley scale. (c) Forest plot of the ASES (American Shoulder and Elbow Surgeons) scale. 95% CI: 95% confidence interval; SMD: mean standard deviation.

Surgical results

Significant differences were found with a higher healing rate at the level of the rotator cuff with the double row technique (OR: 1.85; 95% CI: 1.19–2.87; p=.006) with zero heterogeneity (I=0%; p=.46)18,19,21–23,25–28 (Fig. 5a). Likewise, significant differences were found, with a lower risk of rotator cuff re-tears with the double row technique (OR: 1.54; 95% CI: .35–.84; p=.006) with no heterogeneity (I=.0%; p=.46)18,19,21–23,25–28 (Fig. 5b).

Figure 5.

(a) Forest plot of complete rotator cuff healing. (b) Forest plot of the number of re-tears. 95% CI: 95% confidence interval; OR: odds ratio.

Discussion

The main findings of the study were that there were no significant differences between the single-row and double row groups in clinical outcomes based on the Constant-Murley score or the ASES score. However, the UCLA score and tendon healing were significantly better for the double row technique than for the single-row technique.

No statistically significant differences were found between the two groups in terms of age, sex, and loss to follow-up, thus limiting demographic and loss bias. Study selection and homogeneity play an important role in quality control when performing a meta-analysis.30 Regarding clinical outcomes, significant differences were only found at the level of the UCLA score. This evidence is consistent with previous meta-analyses.11,31 Sobhy et al.,31 in their meta-analysis of 7 RCTs, found a better UCLA score in double row patients (SMD: .69; 95% CI: .19–1.20; p=.007) with no heterogeneity (I=.0%; p=.84). Ying et al.,11 in their meta-analysis of 11 RCTs, also found a better UCLA score in double row patients (SMD: .66; 95% CI: .20–1.13; p=.005) with no heterogeneity (I=0%; p=.89). It should be noted that only 2 RCTs (Imam et al.17 and Carbonel et al.25) had found a difference at the level of the UCLA score between both techniques, these two studies being with a large number of patients studied (Carbonel et al. with 80 patients per group, and Imam et al. with 40 patients per group). In both our meta-analysis and that of Sobhy et al.,31 and Ying et al.11 the study by Carbonel et al.25 was among the studies analysed. This raises the observation that appropriately calculated sample sizes can yield significant differences in functional outcomes, and that most studies, even RCTs, have small sample sizes.18–24,26–29 Excluding the studies by Carbonel et al.,25 and Iman et al.,17 the remaining RCTs analysed did not find clinical differences at the level of any of the three functional scales.18–24,26–29 There are meta-analysis-type studies that disagree with our findings.13,17 Ponugoti et al.,13 in their meta-analysis of 14 studies (6 RCTs, 2 prospective studies, and 6 retrospective studies), found no significant differences between the two techniques on any of the three scales studied in our study (UCLA, Constant, and ASES). However, the majority of their patient sample was from retrospective studies. Sheibani-Rad et al.,14 in their meta-analysis of 5 RCTs, also found no differences between the two techniques on the UCLA, Constant, and ASES scales. However, the RCTs by Carbonel et al.,25 and Iman et al.17 were not included in their study.

There was a higher rate of healing at the rotator cuff level with the double row technique. This finding is consistent with the literature, both with previous meta-analyses and with other types of prospective non-randomised studies and retrospective studies.11,32,33 In their meta-analysis, Ying et al.11 found a higher rate of healing at the rotator cuff level with the double row technique (OR: 1.79; 95% CI: 1.19–2.68; p=.005) with no heterogeneity (I2=0%; p=.78), compared with the single-row technique. Hantes et al.,32 in their prospective non-randomised study of the mid-term radiological and clinical outcomes between single-row and double row fixation techniques for arthroscopic rotator cuff repair in patients younger than 55 years, concluded that the double row repair technique provided better tendon healing. Similarly, Gartsman et al.,33 reported a significantly higher tendon healing rate (as determined by ultrasonographic examination) when using a double row transosseous arthroscopic repair, compared with single-row arthroscopic repair. Xu et al.,34 in their meta-analysis, found in the pooled results a statistically significantly higher incidence of re-ruptures in the single-row repair group (40.2%) compared with the double row group (23.8%). It should be noted that healing and re-rupture rates were measured in the studies included in the meta-analysis18,19,21–23,25–28 and in the studies discussed above32–34 using postoperative ultrasound or MRI. Studies may have clinical outcomes assessed with functional scales that differ from radiological outcomes assessed with MRI or ultrasound. Some studies have shown that improvement in pain and shoulder function does not always correlate with the integrity of the repair.35 However, the literature also reports that patients with improved tendon healing are generally more likely to experience better clinical outcomes.35,36

Some limitations of the present study should be noted. First, the number of included studies is small, which may result in insufficient data. However, only RCTs were included, which is a strength. RCTs can optimise follow-up and data quality, with low selection bias and confounding factors.30 Second, the relatively short follow-up time in the included studies, with only three studies with a follow-up of 36 months. Currently, the comparative data available between single-row and double row techniques for rotator cuff repair are limited. Furthermore, regarding the double row technique, the analysis did not separate whether it was a double row technique or an equivalent transosseous technique, as this was not the current objective of the study. Further high-quality studies are required to evaluate the clinical outcomes and cost-effectiveness of these different techniques.

In conclusion, the double row technique was found to be superior to the single-row technique for rotator cuff repair in terms of a better UCLA score, a better tendon healing rate, and a lower re-rupture rate. No clinically significant differences were found on the Constant-Murley score or the ASES score.

Level of evidence

Level of evidence I.

Funding

We did not receive any financial support from any institution for the preparation of this article.

Conflict of interests

The authors have no conflict of interests to declare.

Annex 1
Summary of the types of rupture, number of tendons involved, rupture size, and fatty atrophy reported in the studies included in this systematic review.

Study  Type of tearDegenerative/traumaticType of tear<3cm/>3cmNumber of tendons involved (only supraspinatus)Fatty atrophy
  SR  DR  p value  SR  DR  p value  SR  DR  p value  SR  DR  p value 
Imam et al.  37/3  36/4  .69  17/23  19/21  .074  NM  NM  NM  NM  NM  NM 
Yamakado et al.  NM/8  NM/4  .17  NM  NM  NM  NM  NM  NM  NM  NM  NM 
Barber col.  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM 
Franceschi et al.  NM/7  NM/8  >.05  11/14  12/13  >.05  10  10  .05  NM  NM  NM 
Nicholas et al.  NM  NM  NM  8/12  7/9  .89  NM  NM  NM  NM  NM  NM 
Carbonel et al.  NM  NM  NM  51/29  53/27  .74  NM  NM  NM  NM  NM  NM 
Lapner et al.  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM 
Ma et al.  NM  NM  NM  19/8  17/9  .69  NM  NM  NM  NM  NM  NM 
Khon et al.  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM 
Aydin et al.  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM  NM 
Burkus et al.  NM  NM  NM  18/2  15/5  NM  NM  NM  NM  NM  NM  NM 
Grasso et al.  NM  NM  NM  NM  NM  NM  19  20  .80  37  35  .27 
Franceschi et al.  NM  NM  >.05  NM/26  NM/26  >.05  12  15  >.05  NM  NM  NM 

DR: double row; SR: single row; NM: not mentioned.

References
[1]
P. Lapner, A. Li, J.W. Pollock, T. Zhang.
A multicenter randomized controlled trial comparing single-row with double-row fixation in arthroscopic rotator cuff repair.
Am J Sport Med, 49 (2021), pp. 3021-3029
[2]
M. Chen, W. Xu, D. Ph, Q. Dong, D. Ph, Q. Huang, et al.
Rotator cuff repair: a systematic review and meta-analysis of current evidence.
Arthrosc J Arthrosc Relat Surg, 29 (2013), pp. 1437-1449
[3]
P.C. Brady, P. Arrigoni, S.S. Burkhart.
Evaluation of residual rotator cuff defects after in vivo single- versus double-row rotator cuff repairs.
Arthroscopy, 22 (2006), pp. 1070-1075
[4]
P.J. Millett, R.J. Warth, G.J. Dornan, J.T. Lee, U.J. Spiegl.
Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials.
J Shoulder Elb Surg, 23 (2014), pp. 586-597
[5]
H. Sugaya, K. Maeda, K. Matsuki, J. Moriishi.
Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation.
Arthroscopy, 21 (2005), pp. 1307-1316
[6]
I.K.B.S. Lo.
Double-row arthroscopic rotator cuff repair: re-establishing the footprint of the rotator cuff.
Arthroscopy, 19 (2003), pp. 1035-1042
[7]
M. Apreleva, O. Mehmet, J.J.P. Warner, O. Biomechanics, B. Israel.
Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area.
Arthroscopy, 18 (2002), pp. 519-526
[8]
Y. Tuoheti, E. Itoi, N. Yamamoto, N. Seki.
Contact area, contact pressure, and pressure patterns of the tendon–bone interface after rotator cuff repair.
Am J Sport Med, 33 (2005), pp. 1869-1875
[9]
S. Fealy, T.P. Kingham, D.W. Altchek.
Mini-open rotator cuff repair using a two-row fixation technique: outcomes analysis in patients with small, moderate, and large rotator cuff tears.
Arthroscopy, 18 (2002), pp. 665-670
[10]
A. Khoriati, T. Antonios, A. Gulihar, B. Singh.
Single vs double row repair in rotator cuff tears – a review and analysis of current evidence.
J Clin Orthop Trauma, 10 (2019), pp. 236-240
[11]
Z. Ying, T. Lin, S. Yan.
Arthroscopic single-row versus double-row technique for repairing rotator cuff tears: a systematic review and meta-analysis.
Orthop Surg, 6 (2014), pp. 300-312
[12]
A.M. Dehaan, T.W. Axelrad, E. Kaye, L. Silvestri, B. Puskas, T.E. Foster.
Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review.
Am J Sport Med, 40 (2012), pp. 1176-1185
[13]
N. Ponugoti, A. Raghu, H.B. Colaco, H. Magill.
A comparison of simple and complex single-row versus transosseous-equivalent double-row repair techniques for full-thickness rotator cuff tears: a systematic review and meta-analysis.
[14]
S. Sheibani-Rad, M.R. Giveans, S.P. Arnoczky, A. Bedi.
Arthroscopic single-row versus double-row rotator cuff repair: a meta-analysis of the randomized clinical trials.
Arthroscopy, 29 (2013), pp. 343-348
[15]
M.J. Page, D. Moher.
Evaluations of the uptake and impact of the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) statement and extensions: a scoping review.
[16]
Cochrane Handbook for Systematic Reviews of Interventions. Cochrane Training n.d. Available from: https://training.cochrane.org/handbook. [Accessed 7 April 2021].
[17]
M. Imam, A. Sallam, L. Ernstbrunner, G. Boyce, N. Bardakos, A. Abdelkafy, et al.
Three-year functional outcome of transosseous-equivalent double-row vs. single-row repair of small and large rotator cuff tears: a double-blinded randomized controlled trial.
J Shoulder Elb Surg, 29 (2020), pp. 2015-2026
[18]
K. Yamakado.
A prospective randomized trial comparing suture bridge and medially based single-row rotator cuff repair in medium-sized supraspinatus tears.
Arthroscopy, 35 (2019), pp. 2803-2813
[19]
R.T. Burks, J. Crim, N. Brown, B. Fink, P.E. Greis.
A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: magnetic resonance imaging and early clinical evaluation.
Am J Sports Med, 37 (2009), pp. 674-682
[20]
A. Grasso, G. Milano, M. Salvatore, G. Falcone, L. Deriu, C. Fabbriciani.
Single-row versus double-row arthroscopic rotator cuff repair: a prospective randomized clinical study.
Arthroscopy, 25 (2009), pp. 4-12
[21]
F. Franceschi, L. Ruzzini, U.G. Longo, F.M. Martina, B.B. Zobel, N. Maffulli, et al.
Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: a randomized controlled trial.
Am J Sport Med, 35 (2007), pp. 1254-1260
[22]
F.A. Barber.
Triple-loaded single-row versus suture-bridge double-row rotator cuff tendon repair with platelet-rich plasma fibrin membrane: a randomized controlled trial.
Arthroscopy, 32 (2016), pp. 753-761
[23]
F. Franceschi, R. Papalia, E. Franceschetti, A. Palumbo, A. del Buono, M. Paciotti, et al.
Double-row repair lowers the retear risk after accelerated rehabilitation.
Am J Sports Med, 44 (2016), pp. 948-956
[24]
S.J. Nicholas, S.J. Lee, M.J. Mullaney, T.F. Tyler, T. Fukunaga, C.D. Johnson, et al.
Functional outcomes after double-row versus single-row rotator cuff repair: a prospective randomized trial.
Orthop J Sport Med, 4 (2016), pp. 14-16
[25]
I. Carbonel, A.A. Martinez, A. Calvo, J. Ripalda, A. Herrera.
Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study.
Int Orthop, 36 (2012), pp. 1877-1883
[26]
H.L. Ma, E.R. Chiang, H.T.H. Wu, S.C. Hung, S.T. Wang, C.L. Liu, et al.
Clinical outcome and imaging of arthroscopic single-row and double-row rotator cuff repair: a prospective randomized trial.
Arthroscopy, 28 (2012), pp. 16-24
[27]
P.L.C. Lapner, E. Sabri, K. Rakhra, S. Mcrae, J. Leiter, K. Bell, et al.
Amulticenter randomized controlled trial comparing single-row with double-row fixation in arthroscopic rotator cuff repair.
J Bone Jt Surg Am, 94 (2012), pp. 1249-1257
[28]
K.H. Koh, K.C. Kang, T.K. Lim, M.S. Shon, J.C. Yoo.
Prospective randomized clinical trial of single- versus double-row suture anchor repair in 2- to 4-cm rotator cuff tears: clinical and magnetic resonance imaging results.
Arthroscopy, 27 (2011), pp. 453-462
[29]
N. Aydin, B. Kocaoglu, O. Guven.
Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears.
J Shoulder Elb Surg, 19 (2010), pp. 722-725
[30]
M.S. Kocher, D. Zurakowski.
Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons.
J Bone Joint Surg Am, 86 (2004), pp. 607-620
[31]
M.H. Sobhy, A.H. Khater, M.R. Hassan, O. el Shazly.
Do functional outcomes and cuff integrity correlate after single- versus double-row rotator cuff repair? A systematic review and meta-analysis study.
Eur J Orthop Surg Traumatol, 28 (2018), pp. 593-605
[32]
M.E. Hantes, Y. Ono, V.A. Raoulis, N. Doxariotis, A. Venouziou, A. Zibis, et al.
Arthroscopic single-row versus double-row suture bridge technique for rotator cuff tears in patients younger than 55 years: a prospective comparative study.
Am J Sports Med, 46 (2018), pp. 116-121
[33]
G.M. Gartsman, G. Drake, T.B. Edwards, H.A. Elkousy, S.M. Hammerman, D.P. O’Connor, et al.
Ultrasound evaluation of arthroscopic full-thickness supraspinatus rotator cuff repair: single-row versus double-row suture bridge (transosseous equivalent) fixation. Results of a prospective, randomized study.
J Shoulder Elb Surg, 22 (2013), pp. 1480-1487
[34]
C. Xu, J. Zhao, D. Li.
Meta-analysis comparing single-row and double-row repair techniques in the arthroscopic treatment of rotator cuff tears.
J Shoulder Elb Surg, 23 (2014), pp. 182-188
[35]
D. Chafik, K. Yamaguchi.
Outcomes after rotator cuff repair: does healing matter?.
Semin Arthroplast JSES, 20 (2009), pp. 116-121
[36]
S.J. Nho, B.S. Brown, S. Lyman, R.S. Adler, D.W. Altchek, J.D. MacGillivray.
Prospective analysis of arthroscopic rotator cuff repair: prognostic factors affecting clinical and ultrasound outcome.
J Shoulder Elb Surg, 18 (2009), pp. 13-20
Copyright © 2023. SECOT
Descargar PDF
Opciones de artículo
Herramientas