Hipotensión en anestesia regional y velocidad de inyección
Hypotension in Regional Anesthesia and Rate of Injection
Visitas
5049
Jorge Andrés Rubio Romero
,
Autor para correspondencia
jarubior@unal.edu.co

Carrera 30 No. 45-03, Facultad de Medicina. Of. 205. Bogotá, Colombia.
* Profesor Asociado, Departamento de Obstetricia y Ginecología, Instituto de Investigaciones Clínicas, Facultad de Medicina, Universidad Nacional de Colombia.
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
RESUMEN
Introducción

Realizar una reflexión sobre el artículo "Anestesia regional subaracnoidea para cesárea y Pomeroy postparto. Aplicación de anestésico local a una velocidad de inyección menor o mayor a 60 segundos", para aproximar al lector a otra perspectiva de los resultados presentados.

Métodos

Se realizó una lectura crítica del artículo mencionado, con el fin de evaluar la calidad metodológica del mismo, las posibles fuentes de sesgo y de error, las variables de confusión y también para revisar los resultados desde esta nueva mirada.

Resultados

La hipotensión es un desenlace frecuente cuando se aplica anestesia subaracnoidea y la velocidad de inyección de la misma puede ser parte de su causa. La serie de casos analizada tiene un tamaño de muestra limitado, por lo que en el estudio se puede presentar sesgo de información y factores de confusión, además de no haberse tenido en cuenta una posible interacción entre la velocidad de infusión y las mezclas de anestésicos empleados.

Conclusión

Es necesario realizar un estudio de cohorte con mayor tamaño de muestra, el cual permita controlar la confusión mediante la estandarización de los procedimientos, el análisis estratificado por subgrupos y el modelamiento matemático para identificar tanto la fuerza de asociación entre la velocidad de inyección del anestésico y la aparición de hipotensión, como las posibles fuentes de confusión e interacción allí presentes.

Palabras clave:
Anestesia
cesárea
anestésicos locales. (Fuente: DeCS BIREME).
Key words:
Anesthesia
C-section
local anesthetics. (Source: MeSH NLM).
SUMMARY
Introduction

To present some thoughts on the article "Regional subarachnoid anesthesia for C-section and post-partum Pomeroy procedure. Application of a local anesthetic at a rate lower or greater than 60 seconds" in order to provide readers with a different perspective regarding the results reported.

Methods

The paper was read critically in order to assess the quality of the methodology, the potential sources of bias and error, the confounding variables, and also to review the results from a fresh perspective.

Results

Hypotension occurs frequently when subarachnoid anesthesia is applied, and the rate of injection may explain it in part. The case series analyzed has a limited sample size, creating the possibility of information bias and confounding factors, not to mention that the potential interaction between the rate of infusion and the mix of anesthetics was not considered.

Conclusion

A cohort study with a larger sample size must be undertaken in order to control confusion by means of standardized procedures, an analysis stratified by subgroups, and mathematical modeling designed to identify the strength of association between the injection rate and the onset of hypotension, as potential sources of confusion and interaction.

El Texto completo está disponible en PDF
References
[1.]
DANE Colombia.
Nacimientos por tipo de parto.
Información estadística, (2010),
[2.]
F. Reynolds, P.T. Seed.
Anaesthesia for caesarean section and neonatal acid-base status: a meta-analysis.
Anaesthesia., 60 (2005), pp. 636-653
[3.]
Rubio-Romero JA, Ángel-Müller E. Operación cesárea. En: Obstetricia integral siglo XXI. 1 ed, tomo II. Disponible en http://www.medicina.unal.edu.co/obstetricia_integral
[4.]
National Collaborating Centre for Women's and Children's Health Commissioned by the National Institute for Clinical Excellence.
Caesarean section Clinical Guideline, (2004),
[5.]
M. Monga.
Maternal cardiovascular and renal adaptation to pregnancy.
Maternal-fetal medicine: principles and practice, 5 ed,
[6.]
F. Althabe, J.F. Belizan.
Caesarean section: The paradox.
The Lancet, 368 (2006), pp. 1472-1473
[7.]
D.C. Hoyos-Cerón, J.R. Navarro-Vargas, J. Eslava-Schmalbach.
Anestesia regional subaracnoidea para cesárea y Pomeroy postparto. Aplicación de anestésico local a una velocidad de inyección menor o mayor a 60 segundos.
Rev. Colomb, Anestesio, 39 (2011 Aug-Oct), pp. 341-350
[8.]
S.I. Singh, P.K. Morley-Forster, M. Shamsah, R. Butler.
Influence of injection rate of hyperbaric bupivacaine on spinal block in parturients: a randomized trial.
Can J Anaesth., 54 (2007 Apr), pp. 290-295
Copyright © 2011. Revista Colombiana de Anestesiología
Opciones de artículo
Herramientas