Buscar en
Enfermería Clínica
Toda la web
Inicio Enfermería Clínica Utilización de tubos para recuento hematológico de polipropileno con EDTA 2K c...
Información de la revista
Vol. 11. Núm. 1.
Páginas 18-22 (Enero 2001)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 11. Núm. 1.
Páginas 18-22 (Enero 2001)
Utilización de tubos para recuento hematológico de polipropileno con EDTA 2K como anticoagulante en un servicio de hematología
The use of polypropylene tubes with EDTA 2K as an anticoagulant for hematologic count in a Department of Hematology
Visitas
2709
Adolfo Romero
,
Autor para correspondencia
jadolfo@airtel.net

Correspondencia: Avda. Dr. Marañón 5, 1.° A. 29009 Málaga
, José Manuel Perea*, Josefa González**, Javier Tronchoni***
* Enfermero especialista en Análisis Clínicos. Hospital Universitario. Mála ga
** Enfermera. Hospital Universitario. Mála ga
*** Supervisor. Servicio de Hematología. Hospital Universitario. Mála ga
Este artículo ha recibido
Información del artículo
Resumen
Bibliografía
Descargar PDF
Estadísticas
Resumen

Para realizar los recuentos hematológicos, nuestro centro dispone de tubos de cristal con EDTA 3K, preparados para extracción al vacío. No obstante, diversas consideraciones nos hacen pensar en la posibilidad de cambiarlos por otros, también preparados para extracciones por sistema de vacío, pero fabricados en polipropileno (plástico) y con EDTA 2K como anticoagulante. El objetivo de este estudio es comprobar si el cambio en el sistema de tubos empleado puede hacer resentir la calidad en el servicio prestado.

Para ello se seleccionó un total de 101 pacientes tomados al azar que fueron divididos en dos grupos. A los pacientes del primero (grupo 1, n = 57) se les extrajeron 2 tubos para recuento sanguíneo, uno de cristal con EDTA 3K y otro de polipropileno con EDTA 2K, siendo estas muestras procesadas en el transcurso de las 2 horas siguientes a la extracción y también a las 24 y a las 48 horas de la misma, conservándolas a 4 °C. En el segundo grupo (grupo 2, n = 44), se realizó idéntico procedimiento, aunque las muestras se conservaron a temperatura ambiente. Se analizaron estadísticamente los resultados del hemograma y las alarmas morfológicas leucocitarias, junto con los tests intra e interensayo. Así mismo, se realizó una investigación cualitativa con los profesionales que colaboraron en la extracción de las muestras. Concluimos que el tubo de plástico para hemograma con EDTA 2K como anticoagulante ofrece resultados fiables, aunque se han detectado ciertos problemas en la manipulación de las muestras que merecen ser estudiados más profundamente.

Palabras clave:
Hemograma
Tubos de extracción sanguínea
Sistema de vacío
EDTA 2K

To carry out hematologic counts our center uses glass tubes with EDTA 3K prepared for vacuum extraction. Nonetheless, different considerations have led to the possibility of changing these for other tubes which are also prepared for vacuum extractions but which are made of polypropylene (plastic) with EDTA 2K as the anticoagulant. The aim of this study was to prove whether the change in the tubes used may alter the quality in the service rendered. A total of 101 patients were randomly selected and divided into two groups. In group 1 (n = 57) 2 tubes were used for blood counts, one of glass with EDTA 3K and the other of polypropylene with EDTA 2K. These samples were processed over 2 hours after the extraction and also at 24 and 48 hours and were preserved at 4 °C. In group 2 (n = 44) an identical procedure was carried out, although the sample were preserved at room temperature. The results of the hemogram and the leucocyte morphologic alarms, together with the intra-and interassay tests were statistically analyzed. Moreover, a qualitative investigation was made with the professionals who collaborated in sample extraction. It was concluded that the plastic tubes with EDTA 2K as the anticoagulant provide reliable results for blood counts, although certain problems were detected in sample manipulation which should be more closely studied.

Keywords:
Hemogram
Blood extraction tubes
Vacuum system
EDTA 2K

Artículo

Opciones para acceder a los textos completos de la publicación Enfermería Clínica
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Enfermería Clínica

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos