Buscar en
Colombian Journal of Anesthesiology
Toda la web
Inicio Colombian Journal of Anesthesiology Test dose in regional anesthesia
Información de la revista
Vol. 42. Núm. 1.
Páginas 47-52 (Enero - Marzo 2014)
Visitas
10968
Vol. 42. Núm. 1.
Páginas 47-52 (Enero - Marzo 2014)
Review
Acceso a texto completo
Test dose in regional anesthesia
Dosis de prueba para anestesia regional
Visitas
10968
Luz Adriana Galindo Gualdrón
Autor para correspondencia
luzagalindo@yahoo.com

Corresponding author: Universidad El Bosque, Anestesiología; diagonal 136 núm. 86-59 casa 54 Bogotá, Colombia.
Doctor Specialist in Anesthesiology, Hospital Simón Bolívar, Teaching associate instructor, Universidad del Bosque, School of Medicine, Postgraduate Anesthesiology, Bogotá, Colombia
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Abstract
Introduction

The use of the test dose in regional anesthesia is not standardized, and there is no consensus regarding what dose it should be or about the anesthetic or type of drug to be used. Moreover, many anesthesiologists do not use it routinely in their practice.

Objective

To review the test dose for regional anesthesia, its indications and utility, the drugs used, and positive signs.

Methods

A non-systematic search was conducted in medical database publications including MedLine, SciELO and Embase.

Results

The application of the test dose before giving the full injection of the local anesthetic helps in detecting the inadvertent placement of the needle or catheter in the intravascular or the subarachnoid spaces.

Conclusions

The test dose must be used every time critical doses of a local anesthetic are utilized or when normal doses are given to patients with risk factors. The test dose is not necessary in labor analgesia.

Keywords:
Anesthesia
Conduction
Anesthesia
Local
Toxicity
Anesthesia
Epidural
Lidocaine
Resumen
Introducción

El uso de la dosis de prueba en anestesia regional no está estandarizado: no existe consenso sobre su dosis, el anestésico o el tipo de fármaco que se debe utilizar, y muchos anestesiólogos no la utilizan rutinariamente en su práctica.

Objetivo

Hacer una revisión de la dosis de prueba para anestesia regional, sus indicaciones, su utilidad, los fármacos utilizados para ella y los signos considerados como positivos.

Métodos

Se realizó una búsqueda no sistemática de publicaciones en bases de datos médicas que incluyeron MedLine, SciELO y Embase.

Resultados

La aplicación de la dosis de prueba previa a la inyección total de anestésico local ayuda a detectar la colocación inadvertida de una aguja o catéter en el espacio intravascular o subaracnoideo.

Conclusiones

La dosis de prueba debe utilizarse siempre que se utilicen dosis críticas de anestésico local o incluso dosis normales en pacientes con factores de riesgo. En analgesia para trabajo de parto la dosis de prueba no es necesaria.

Palabras clave:
Anestesia de conducción
Anestesia local
Toxicidad
Anestesia epidural
Lidocaína
Texto completo
Introduction

In all procedures where substantial doses of local anesthetic are used there is a possibility of the inadvertent injection into the intravascular or subarachnoid space, or of massive systemic absorption and subsequent toxicity.

Even at therapeutic doses, the inadvertent administration of the local anesthetic into the intravascular space may have fatal consequences, and resuscitation following local anesthetic-induced circulatory collapse is very difficult.1 Consequently, early identification, a high degree of suspicion, and constant application of various preventive measures are required.2

The consensus of the American Society of Regional Anesthesia underscores the importance of prevention in reducing the frequency and severity of toxicity due to local anesthetics. Although imperfect, the test dose is the most reliable method for the early detection of intravascular3,4 or intra-spinal placement of a needle or catheter.

The goal of the test dose in regional blocks is to rule out inadvertent intravascular injection, while in epidural blocks the goal is to rule out the presence of the needle or the catheter either in the subarachnoid or the intravascular space.

The use of the test dose is not standardized, as there are multiple controversies regarding its safety, and there is no consensus about the dose, the anesthetic or the type of drug to be used. In obstetrics, for example, despite the fact that not giving a test dose before an emergency cesarean section is associated with severe consequences for the mother and the fetus, most obstetric anesthesiologists in Britain do not use a test dose5 in patients, previously managed with peridural analgesia, taken to emergency cesarean section. In our setting, although there are no statistics, this practice is also very common.

Hence the importance of reviewing the indications, utility, positive results, and the way of using the test dose.

Methods

A non-systematic search was conducted in medical database publications including MedLine, SciELO and Embase. The following MESH terms were used: regional anesthesia and test dose, local Anesthetic and Toxicity.

The test dose

Ideally, a test dose must detect the wrong placement or migration of the needle or catheter into the intravascular or the subarachnoid space, and never yield a false positive response. It must be safe, effective and reliable, allowing practical interpretation within a reasonable period of time.6,7

In order to detect subarachnoid placement, the test dose must prevent a high block leading to respiratory problems or cardiovascular instability.8,9 In order to detect intravascular placement, it must be able to elicit clear clinical signs and symptoms of toxicity of rapid onset, either cardiovascular or of the central nervous system; these should resolve rapidly and have little probability of causing harm.10

Multiple studies have tried to determine the components of an effective test dose.9–12 Moore and Batra conclude that the test dose for peridural block must contain 0.015mg of epinephrine in order to detect the intravascular component, and local anesthetic to induce prompt spinal anesthesia.13

The use of lidocaine as a single component of the test dose has been described, with reports of presentation of atypical symptoms.14 When direct intravascular injection occurs, prodromic signs may be missed or not appear, and the patient may move rapidly to develop seizure activity or symptoms of agitation or cardiac depression.15 Particularly with the more potent local anesthetics, cardiotoxicity may occur simultaneously with seizures, or even precede them.14

Studies with ropivacaine and levobupivacaine have shown several limitations regarding the use of these two drugs as a test dose.16,17

The use of hyperbaric solutions has been recommended in test doses in order to limit the extent of the block, should the injection go to the subarachnoid space.18–22 However, due to the commercial unavailability of preparations containing hyperbaric lidocaine and epinephrine, many authors continue to recommend the dextrose-free solution.21,22

Hemodynamic changes brought about with the test dose with epinephrine are usually not observed or are hidden or diminished in the elderly, in patients with sedation, beta-blockers or under general anesthesia, in women in labor3–5,13 and in patients with low output.2 This has created the need for alternative methods for determining whether the catheter or needle for regional block has been placed in the intravascular space. Some proposed methods include: an injection of 1–2cm3 of air during chest auscultation, using Doppler evidence for the presence of air.23 In children under general anesthesia, changes in T-wave amplitudes have been described after administering epinephrine, as a reliable indicator of accidental intravenous injection.6,24–26 In labor, it has been found that fentanyl can be used reliably and safely as an intravenous test dose.27,28

Among the various options, only fentanyl and epinephrine meet the suggested applicability and reliability standards for the detection of intravascular injection, according to the American Society of Regional Anesthesia. It has been shown that 100mcg of intravenous fentanyl produces reliable symptoms of drowsiness and sedation in patients in labor.4,27 As for epinephrine, a dose of 10–15mcg/ml has a positive predictive value and 80% sensitivity for the detection of intravascular injection in adults if heart rate increases by 10 or more beats per minute, or if the systolic blood pressure rises by 15mmHg or more.3,4,7

Finally, it is important to bear in mind that a negative test dose does not mean that there is no risk of incorrect placement or migration of the needle or catheter. A test dose is of diagnostic value only when it is positive; a slow injection with frequent aspirations and continuous electrocardiographic monitoring while administering the drug continues to be mandatory.1,6

ReviewTest dose in epidural analgesia for labor

The indication of the test dose in peridural analgesia for labor is controversial.

The addition of epinephrine to the intra-thecal component of the test dose in women in labor is sensitive but not specific; this means that a certain percentage of positive responses do not represent a true intravascular placement of the peridural catheter, leading to unnecessary removal.29

The test dose with lidocaine before initiating peridural analgesia may cause motor blockade and interfere with proper ambulation during the first 30–60min.12,30

It is believed that the accidental injection of low-dose, low-concentration solutions of local anesthetics, used frequently in labor analgesia, does not cause systemic toxicity,31 and that the test dose is unnecessary considering that ultra-diluted solutions commonly used, together with aspiration, are usually diagnostic in themselves.29,32,33

Considering that not only local anesthetics but also opioids are used in obstetric analgesia, there are reports of changes in fetal heart rate and uterine hypertonia with intra-thecal or intravascular injections. Consequently, in cases where an epidural mix containing opioids is used for analgesia, careful monitoring and correct interpretation of fetal heart rate are required.34–36

It is also important to consider that when therapeutic analgesic doses are used as a test dose, the total dose may be equivalent to the one used for subarachnoid anesthesia. Therefore, if the catheter is placed intra-thecally, the mother will present sensory motor block and hemodynamic compromise, which may affect fetal wellbeing.31

Birnbach and Browne conclude that, regardless of the technique used, the safe practice for the administration of epidural analgesia in labor requires initial catheter aspiration, gradual dose increases and continuous monitoring during and after catheter placement in order to detect any sign of anesthetic toxicity, bearing in mind that an epidural analgesia infusion that has been working well and stops having the desired effect may be an indication of catheter migration.33,37

Test dose in cesarean section

Peridural anesthesia, with or without a catheter, may give rise to complications due to inadvertent intravascular or subarachnoid puncture. In such circumstance, the injection of critical amounts of local anesthetic may be life threatening.38

The incidence of inadvertent intravascular injection in obstetric patients is estimated to range from 4.9% to 7%, higher than the 2.8% rate in non-pregnant patients,10,29 and drops from 0.6% to 2.3% with aspiration before the injection.31,39,40 Subarachnoid catheterization occurs approximately in 0.6–2.7% of cases, and is usually detected because of the exit of cerebrospinal fluid through the needle or catheter.12,31,41

There are multiple reports of inadvertent intravenous injections for cesarean section in catheters that had been working normally and had been tested for peridural analgesia42; this may happen due to catheter migration43 or, as shown by

Hogan,44 in multiport catheters: with slow, low-pressure injection, the fluid exits through the proximal orifice; when the fluid is injected more rapidly or under greater pressure, the flow occurs mainly through the distal orifice. Consequently, if the catheter is placed only partially in the subarachnoid space, the continuous peridural analgesia infusion may be delivered through the proximal orifice into the peridural space, but when the total anesthetic dose for cesarean section is delivered at a faster rate, it may flow through the distal orifice into de subarachnoidal space. It may be inferred that the same thing may happen if the catheter is partially placed into the intravascular space.

Routine aspiration of the catheter will usually identify incorrect placement, but aspiration may yield false positive results.12

In cases of elective cesarean section, the use of a test dose is mandatory.31

It is not clear whether epinephrine should be used in obstetric patients, whose unique conditions may affect the sensitivity and applicability of the test. These conditions include uterine contractions, pre-eclampsia, lower thresholds for heart rate increases, and risk of reduced uterine blood flow; regarding the latter, there are no clinical data of fetuses that have sustained harm or been at risk as a result of the test dose.45,46

In view of all of the above, many authors have studied fentanyl as a test dose and have found that, if delivered intravascularly, it produces predictable and easily detectable symptoms, with a 92.4% sensitivity and a 92% specificity. Therefore, they suggest the use of 100mcg as an intravascular test dose in obstetric patients.4,7,27,28

For Colona et al., the controversy on the use of epinephrine in the test dose is non-existent in elective cesarean section. In this case, a sudden increase in maternal heart rate by more than 10 beats per minute, lasting 30–60s, within the first 30s after the administration, is considered a safe sign of intravascular placement.47

In patients taken to emergency cesarean section, the time delay in establishing the block for the surgery because of the test dose is insignificant compared to the risk to which the patient may be exposed. Despite maternal heart rate variability, it is easy to detect the rapid development of a peak maternal heart rate following the intravascular injection of 12.5mcg of epinephrine.48 Nonetheless, Rueda et al., recommend, in patients scheduled for urgent cesarean section, NICE categories 2 and 3 who come with peridural analgesia, the use of 2% lidocaine plus epinephrine as anesthetic, considering its low neurological and cardiovascular toxicity profile and reduced latency time.49

Due to large volumes of local anesthetics delivered to the epidural space for cesarean section, several authors recommend various measures to reduce the risk of toxicity from local anesthetics. First, before using it, catheter aspiration is required and the appropriate test dose must be administered. Second, the anesthetic must be delivered in fractionated doses. Finally, the drugs of choice must preferably be safe drugs like chlorprocaine and lidocaine, or the new amine-type local anesthetics like ropivacaine and levobupivacaine.3,31,37

Test dose using the combined spinal–epidural technique

When this technique is used, the onset of analgesia is fast and it is not possible to test the peridural catheter until the effects of the initial spinal dose fade away. The greatest disadvantage is that the real location of the peridural catheter is uncertain during this period. In any case, the test dose is recommended every time the peridural catheter is used initially either for a rescue dose or for post-operative pain management.31,50,51

Considering that an intentional arachnoidal perforation is made, there is concern of a greater possibility of migration of the peridural catheter tip.51 However, such an event would occur only after multiple dural perforations, considering the impossibility of introducing an epidural catheter though a dural orifice previously made with a 25-gauge needle.52

Test dose for procedures under peridural anesthesia

Although the test dose given before the induction of epidural anesthesia may take 5–10min longer, knowing whether the catheter is placed correctly is better quality care and offers enhanced safety for perioperative care.53

Test dose in pediatrics

Regional caudal and epidural analgesia are accepted as safe and reliable methods for delivering perioperative analgesia in children.54,55 An incidence of up to 5.6% of accidental intravascular puncture has been reported, and aspiration before the injection fails to detect up to 86% of intravascular placements.25

The recommended epidural test dose is 0.1ml/kg of 1% lidocaine plus 0.5mcg/kg of epinephrine. In children, most blocks are performed under general anesthesia, which may alter hemodynamic responses to the test dose during intravascular injection.6 Consequently, besides careful observation of any increase of more than 10 beats per minute in heart rate or of more than 15mmHg in blood pressure with epinephrine,24 several authors have found that a more reliable parameter to detect intravascular injection are changes of 25% in T wave amplitude in lead DII of the electrocardiogram, both visually in the anesthesia monitor and in the printed EKG result, in children receiving general anesthesia with sevorane.6,24,25,56

Test dose in peripheral nerve blocks

The use of peripheral blocks has been associated with adverse events secondary to toxicity from local anesthetics.57

The site of the block, the intrinsic vasoactivity of the local anesthetic, the use of epinephrine, and patient-related factors such as heart, liver or kidney disease are the most important predictors of the plasma levels of local anesthetics that may be reached.3

Although real-time ultrasound-guided blocks may be particularly useful for ensuring the correct delivery of the local anesthetic around the nerve, avoiding other structures,58 there are no retrospective controlled studies that confirm or refute reduced toxicity due to local anesthetics, in particular when considering frequent needle movements inherent to the technique.59,60

For the consensus of the American Society of Regional Anesthesia, prevention of intravascular injection must be based on a combination of ultrasound-guided block and a test dose with epinephrine, especially in procedures where large amounts of local anesthetics are used.3

Regarding the risk of nerve injury from the use of epinephrine, it is not clear if the additive injury in humans is clinically relevant over and above the primary cause of the local anesthetic itself.61

Conclusions

Systemic toxicity due to inadvertent intravascular injection of the local anesthetic may occur during any regional anesthesia technique. Consequently, an appropriate test dose with fractionated injection, adequate monitoring and immediate availability of the airway management and resuscitation equipment and, in particular, vigilant attitude, continue to be essential for ensuring patient safety.

A test dose must be used every time critical doses of local anesthetic are employed, or even normal doses in patients with risk factors, for all types of regional blocks.

The recommended drugs for the test dose are 1% lidocaine with epinephrine and fentanyl in obstetric patients. The variables that need to be monitored are heart rate, blood pressure, the T wave in the electrocardiogram, and consciousness changes.

The time delay and the risk from placing the test dose are insignificant when compared to the serious complications that may occur if the inadvertent puncture goes undetected.

In labor analgesia there is no need for a test dose, considering that the doses delivered for analgesia may play that role.

The test dose should be mandatory in patients receiving peridural anesthesia for cesarean section, because not using it means placing the patient at risk of toxicity from local anesthetics.

Funding

None.

Conflict of interest

The author has no conflicts of interest to declare.

References
[1]
C.B. Berde, G.R. Strichartz.
Local anesthetics.
Anesthesia, 7th ed., pp. 932-937
[2]
R.M. Valencia, H.F. García.
Toxicidad por anestésicos locales: revision de la literature.
Rev Colomb Anestesiol, 39 (2011), pp. 40-54
[3]
J.M. Neal, C.M. Bernards, J.F. Butterworth 4th, G. Di Gregorio, K. Drasner, M.R. Hejtmanek, et al.
ASRA practice advisory on local anesthetic systemic toxicity.
Reg Anesth Pain Med, 35 (2010), pp. 152-161
[4]
M.F. Mulroy, M.R. Hejtmanek.
Prevention of local anesthetic systemic toxicity.
Reg Anesth Pain Med, 35 (2010), pp. 177-180
[5]
I.C. Gardner, S.M. Kinsella.
Obstetric epidural test doses: a survey of UK practice.
Int J Obstet Anesth, 14 (2005), pp. 96-103
[6]
E. Varghese, D.K. Mukundarao, K.V. Chowdary.
Epinephrine test dose in children: is it interpretable on ECG monitor?.
Pediat Anesth, 19 (2009), pp. 1090-1095
[7]
J. Guay.
The epidural test dose: a review.
Anesth Analg, 102 (2006), pp. 921-929
[8]
B. Poblete, E.F. Van Gessel, G. Gaggero, Z. Gamulin.
Eficacy of three test doses to detect epidural catheter misplacement.
Can J Anesth, 46 (1999), pp. 34-39
[9]
M. Camorcia, G. Capogna, M.O. Columb.
Estimation of the minimum motor blocking potency ratio for intrathecal bupivacaine and lidocaine.
Int J Obstet Anesth, 17 (2008), pp. 223-227
[10]
M.D. Owen, P. Gautier, D.D. Hood.
Can ropivacaine and levobupivacaine be used as test doses during regional anesthesia?.
Anesthesiology, 100 (2004), pp. 922-925
[11]
M. Camorcia, G. Capogna.
Standard lidocaine test dose: isn’t it too much?.
Eur J Anaesth, 21S (2004), pp. 154-155
[12]
M.G. Richardson, A.C. Lee, R.N. Wissler.
High spinal anesthesia after epidural test dose administration in five obstetric patients.
Reg Anesth, 21 (1996), pp. 119-123
[13]
D.C. Moore, M.S. Batra.
The components of an effective test dose prior to epidural block.
Anesthesiology, 55 (1981), pp. 693-696
[14]
M.C. Vallejo, S.T. Beaman, S. Ramanatha.
Blurred vision as the only symptom of a positive epidural test dose.
Anesth Analg, 102 (2006), pp. 965-976
[15]
S.K. Mishra, A. Subramanian, B. Hemavathi, A. Badhe.
Convulsion and cardiorespiratory collapse with first epidural test dose.
J Anesth, 25 (2011), pp. 635-636
[16]
M. Camorcia, G. Capogna, G. Lyons, M. Columb.
Epidural test dose with levobupivacaine and ropivacaine: determination of ED(50) motor block after spinal administration.
Br J Anaesth, 92 (2004), pp. 850-853
[17]
W.D. Ngan Kee, K.S. Khaw, M.B.B.S. Lee, B.B.E.L. Wong, R.N.J.Y. Liu.
The limitations of ropivacaine with epinephrine as an epidural test dose in parturients.
Anesth Analg, 92 (2001), pp. 1529-1531
[18]
J.K. Batra, A. Sharma, S. Rajeev.
Total spinal anaesthesia following epidural test dose in an ankylosing spondylitic patient with anticipated difficult airway undergoing total hip replacement.
Eur J Anaesthesiol, 23 (2006), pp. 897-898
[19]
N. Hoftman, K. Chan.
Two cases of horner syndrome after administration of an epidural test dose that did not recur with subsequent epidural activation.
Reg Anesth Pain Med, 34 (2009), pp. 372-374
[20]
R.A. Abraham, A.P. Harris, L.G. Maxwell, S. Raplow.
The efficacy of 1.5% lidocaine with 7.5% dextrose and epinephrine as an epidural test dose for obstetrics.
Anesthesiology, 64 (1986), pp. 116-119
[21]
G. Prince, D. McGregor.
Obstetric epidural test doses.
Anaesthesia, 41 (1986), pp. 1240-1250
[22]
D.R. Biehl.
The dilemma of the epidural test dose.
Can J Anaesth, 34 (1987), pp. 545-548
[23]
B.L. Leighton, M.C. Norris, C.A. deSimone, T. Rosko, J.B. Gross.
The air test as a clinically useful indicator of intravenously placed epidural catheters.
Anesthesiology, 73 (1990), pp. 610
[24]
M. Tanaka, T. Nishikawa.
Evaluating T-wave amplitude as a guide for detecting intravascular injection of a test dose in anesthetized children.
Anesth Analg, 88 (1999), pp. 754-758
[25]
Q.A. Fisher, D.H. Shaffner, M. Yaster.
Detection of intravascular injection of regional anaesthetics in children.
Can J Anaesth, 44 (1997), pp. 592-598
[26]
M. Tanaja, T. Nishikawa.
Does the choice of electrocardiography lead affect the efficacy of the T-wave criterion for detecting intravascular injection of an epinephrine test dose?.
Anesth Analg, 95 (2002), pp. 1408-1411
[27]
W.Y. Yoshii, M. Miller, R.L. Rottman, D.M. Kotelko, W.C. Wright, J.J. Stone, et al.
Fentanyl for epidural intravascular test dose in obstetrics.
Reg Anesth, 18 (1993), pp. 296-299
[28]
G.F. Morris, W. Gore-Hickman, S.A. Lang, R.W. Yip.
Can parturients distinguish between intravenous and epidural fentanyl?.
Can J Anaesth, 41 (1994), pp. 667-672
[29]
M.C. Norris, T.S. Fogel, H. Dalman, S. Borrenpohl, W. Hoppe, A. Riley.
Labor epidural analgesia without an intravascular ‘test dose’.
Anesthesiology, 88 (1998), pp. 1495-1501
[30]
A.L. Calimaran, T.P. Strauss-Hoder, W.Y. Wang, R.J. McCarthy, C.A. Wong.
The effect of epidural test dose on motor function after a combined spinal epidural technique for labor analgesia.
Anesthesiology, 96 (2003), pp. 1167-1172
[31]
M. Carmocia.
Testin de epidural catéter.
Curr Opin Anaesthesiol, 22 (2009), pp. 336-340
[32]
M.C. Norris, D. Ferrenbach, H. Dalman, S.T. Folgen, S. Borrenpohl, W. Hoppe, et al.
Does epinephrine improve the diagnostic accuracy of aspiration during labor epidural analgesia?.
Anesth Analg, 88 (1999), pp. 1073-1076
[33]
A. Van Zundert, L. Vaes, M. Soetens, M. de Vel, P. Van der Aa, A. Van der Donck, et al.
Every dose given in epidural analgesia for vaginal delivery can be a test dose.
Anesthesiology, 67 (1987), pp. 436-440
[34]
M. Van de Velde, A. Teunkens, M. Hanssens, E. Vandermeersch, J. Verhaghe.
Intrathecal sufentanil and fetal heart rate abnormalities: a double blind, double placebo-controlled trial comparing two forms of combined spinal epidural analgesia with epiduralanalgesia in labor.
Anesth Analg, 98 (2004), pp. 1153-1159
[35]
J.A. Russel, R.G. Gosden, E.M. Humphreys, R. Cutting, N. Fitzsimons, V. Johnston, et al.
Interruption of parturition in rats by morphine: A result of inhibition of oxytocin secretion.
J Endocrinol, 121 (1989), pp. 521-536
[36]
A. Bergman, N. Eckstein, G. Yedwab, M.P. David.
Fetal distress due to intravenous administration of petidine (meperidine) with promethazine during labour.
Aust N Z J Obstet Gynaecol, 22 (2008), pp. 215-217
[37]
D.J. Birnbach, I.M. Browne.
Anesthesia for obstetrics.
Anesthesiology, 7th ed., pp. 2215-2225
[38]
G.W. Kasten, S.T. Martin.
Resuscitation from bupivacaine-induced cardiovascular toxicity during partial inferior vena cava occlusion.
Anesth Analg, 65 (1986), pp. 341-344
[39]
P.H. Pan, T.D. Bogard, M.D. Owen.
Incidence and characteristics of failures in obstetric neuraxial analgesia and anesthesia: a retrospective analysis of 19,259 deliveries.
Int J Obstet Anesth, 13 (2004), pp. 227-233
[40]
B.L. Leighton, W.G. Topkis, J.B. Gross, V.A. Arkoosh, S.H. Lee, H.J. Huffnagle, S.L. Huffnagle.
Multiport epidural catheters: Does the air test work?.
Anesthesiology, 92 (2000), pp. 1617-1620
[41]
M.C. Norris, W.M. Grieco, M. Borkowski, B.L. Leighton, V.A. Arkoosh, J. Huffnagle, et al.
Complications of labor analgesia: epidural versus combined spinal epidural techniques.
Anesth Analg, 79 (1994), pp. 529-537
[42]
A. Spence.
Lipid reversal of central nervous system symptoms of bupivacaine toxicity.
Anesthesiology, 107 (2007), pp. 516-517
[43]
P.G. Langevin, N. Gravenstein, S.O. Langevin, P.A. Gulig.
Epidural catheter reconnection: Safe and unsafe practice.
Anesthesiology, 85 (1996), pp. 883
[44]
Q. Hogan.
Distribution of the solution in the epidural space. Examination by chryomicrotome section.
Reg Anesth Pain Med, 27 (2002), pp. 150-156
[45]
D.D. Hood, D.M. Dewan, F.M. James.
Maternal and fetal effects of epinephrine in gravid ewes.
Anesthesiology, 64 (1986), pp. 610
[46]
M. Mulroy, B. Glosten.
The epinephrine test dose in obstetrics: note the limitations.
Anesth Analg, 86 (1998), pp. 923-925
[47]
P. Colonna Romano, N. Lingaraju, S.D. Godfrey, L.E. Britman.
Epidural test dose and intravascular injection in obstetrics: sensitivity, specificity and lowest effective dose.
Anesth Analg, 75 (1992), pp. 372-376
[48]
P.D. Cartwright, S.M. McCarroll, C. Antzaka.
Maternal heart rate changes with a plain epidural test dose.
Anesthesiology, 65 (1986), pp. 226-228
[49]
F. Rueda, J.V.F.C.E. Pinzón, R.M. Vasco.
Manejo anestésico para operación cesárea urgente: revisión sistemática de la literatura de técnicas anestésicas para cesárea urgente.
Rev Colomb Anestesiol, 40 (2012), pp. 273-286
[50]
L.F. Garcia Gutierrez.
Anestesia Combinada Espinal-Epidural y sus Ventajas en Obstetricia.
Anest México, 19 (2007), pp. 147-154
[51]
I.C. Shaw, R.J. Birks.
A case of extensive block with the combined spinal–epidural technique during labour.
Anaesthesia, 56 (2001), pp. 346-349
[52]
B. Holmstrom, N. Rawal, K. Axelsson, P.-A. Nydahl.
Risk of catheter migration during combined spinal epidural block: percutaneous epiduroscopy study.
Anesth Analg, 80 (1995), pp. 747
[53]
J. Larson, T.E. Gordh.
Testing whether the epidural works: too time consuming?.
Acta Anaesthesiol Scand, 54 (2010), pp. 761-763
[54]
M. Yaster, L.G. Maxwell.
Pediatric regional anesthesia.
Anesthesiology, 70 (1989), pp. 324-338
[55]
B. Dalens.
Regional anesthesia in children.
Anesth Analg, 68 (1989), pp. 654-672
[56]
M. Tanaka, T. Nishikawa.
Simulation of an epidural test dose with intravenous epinephrine in sevoflurane-anesthetized children.
Anesth Analg, 86 (1998), pp. 952-957
[57]
D.L. Brown, D.M. Ransom, J.A. Hall, C.H. Leicht, D.R. Schroeder, K.P. Offord.
Regional anesthesia and local anesthetic-induced systemic toxicity: Seizure frequency and accompanying cardiovascular changes.
Anesth Analg, 81 (1995), pp. 321-328
[58]
S. Kapral, M. Greher, G. Huber, H. Willschke, S. Kettner, R. Kdolsky, et al.
Ultrasonographic guidance improves the success rate of interscalene brachial plexus blockade.
Reg Anesth Pain Med, 33 (2008), pp. 253-258
[59]
J.M. Neal.
Ultrasound-guided regional anesthesia and patient safety: an evidence-based analysis.
Reg Anesth Pain Med, 3 (2010), pp. S59-S67
[60]
R.J. Zetlaoui, J.-P. Labbe, D. Benhamou.
Ultrasound guidance for axillary plexus block does not prevent intravascular injection.
Anesthesiology, 108 (2008), pp. 761
[61]
J.M. Neal.
Effects of epinephrine in local anesthetics on the central and peripheral nervous systems: neurotoxicity and neural blood flow.
Reg Anesth Pain Med, 28 (2003), pp. 124-134

Please cite this article as: Galindo Gualdrón LA. La dosis de prueba para anestesia regional. Rev Colomb Anestesiol. 2014;42:47–52.

Copyright © 2013. Sociedad Colombiana de Anestesiología y Reanimación
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos