Buscar en
Cirugía Española
Toda la web
Inicio Cirugía Española Separación del sistema de imagen del dispositivo de cirugía laparoendoscópica...
Información de la revista
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
695
Innovación en técnica quirúrgica
Separación del sistema de imagen del dispositivo de cirugía laparoendoscópica de puerto único en cirugía endoscópica uniportal: proyecto ZEUS
Splitting the imaging system from the laparoendoscopic single site surgery device in endoscopic uniportal surgery: ZEUS project
Visitas
695
Andrés Arroyo Tristán
Servicio de Cirugía de Tórax, Hospital Universitario Virgen de la Arrixaca, Murcia, España
Este artículo ha recibido
Recibido 08 junio 2021. Aceptado 10 julio 2021
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (8)
Mostrar másMostrar menos
Resumen

El uso de un endoscopio de tubo rígido (RTE) a través de un dispositivo de cirugía laparoendoscópica de puerto único durante la cirugía endoscópica uniportal (EUS) está directamente relacionado con el efecto fulcro y la competencia física (entre cirujanos y a través del puerto).

En un intento de separar el sistema de imagen del dispositivo cirugía laparoendoscópica de puerto único, se describe un proyecto escalonado (3 modelos) para ayudar a superar estos inconvenientes. ZEUS1, un nuevo dispositivo de sistema de imagen sin RTE para EUS, fue probado con éxito en cirugía EUS en un modelo porcino. Aún en investigación, ZEUS2 se convierte en una estructura cableada que sirve de base a una microcámara endoscópica intracavitaria con funciones de giro, inclinación y zoom. ZEUS3 contempla el aro interno del protector de herida quirúrgica como una corona de microcámaras. Son necesarios nuevos estudios para materializar los modelos ZEUS2 y ZEUS3 y confirmar su eficacia y seguridad.

Palabras clave:
Uniportal
LESS
Microcámara
Endoscópica
PTZ
ZEUS
Abstract

The use of a rigid tube endoscope (RTE) through a laparoendoscopic single site surgery device for intracavitary visualization during endoscopic uniportal surgery (EUS) is directly related to the fulcrum effect and physical competition (externally between surgeons and on instrumentation through the single port). These facts may have precluded a wider spread of EUS. In an attempt to separate the imaging system from the laparoendoscopic single site surgery device, a tiered project (3 models) that can help overcome these drawbacks is detailed. ZEUS1, a new non-RTE imaging system device for EUS was successfully tested in EUS surgery in a pig model. Still under investigation, ZEUS2 becomes a wired structure that serves as the basis for an endoscopic microcamera with intracavitary pan-tilt-zoom functions. ZEUS3 uses the inner ring of the surgical wound protector as a microchamber crown. Further studies are needed to materialize the ZEUS2 and ZEUS3 models and confirm their efficacy and safety.

Keywords:
Uniportal
LESS
Endoscopic
Microcamera
PTZ
ZEUS

Artículo

Opciones para acceder a los textos completos de la publicación Cirugía Española
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Cirugía Española

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos