metricas

Radiología (English Edition)

Suggestions
Radiología (English Edition) Cone Beam computed tomography (CBCT) applications in image-guided minimally inva...
Journal Information
Vol. 67. Issue 1.
Pages 1-112 (January - February 2025)
Cite
Cite
Share
Download PDF
More article options
Visits
2890
Vol. 67. Issue 1.
Pages 1-112 (January - February 2025)
Update in Radiology

Cone Beam computed tomography (CBCT) applications in image-guided minimally invasive procedures

Aplicaciones de la tomografía computarizada de haz cónico en procedimientos mínimamente invasivos guiados por imagen
Visits
2890
E. Serranoa, J. Valcárcel Joséa, A. Páez-Carpiob, M. Matute-Gonzálezb, M.F. Wernerb, A. López-Ruedab,
Corresponding author
alrueda81@hotmail.com

Corresponding author.
a Centro de Diagnóstico por la Imagen, Sección de Radiología Vascular Intervencionista, Hospital Universitario de Bellvitge, Hospitalet de Llobregat, Barcelona, Spain
b Centro de Diagnóstico por la Imagen, Sección de Radiología Vascular e Intervencionista, Hospital Clínic de Barcelona, Barcelona, Spain
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Abstract

Cone-Beam computed tomography (CBCT) obtains three-dimensional images using a two-dimensional detector. The use of CBCT in treatment planning and evaluation increases the safety and efficacy of minimally invasive procedures. This article reviews the technical considerations, main clinical applications, and future directions of CBCT in vascular and interventional radiology and interventional neuroradiology.

Keywords:
Cone beam computed tomography
Interventional radiology
Endovascular procedure
Embolisation
Ablation technique
Resumen

La tomografía computarizada de haz cónico (CBCT), de sus siglas en inglés “Cone-Beam computed tomography”, obtiene imágenes tridimensionales mediante un detector bidimensional. Su aplicación en la planificación y evaluación de los procedimientos mínimamente invasivos guiados por imagen, puede mejorar tanto la seguridad como la eficacia de intervenciones vasculares y percutáneas. El objetivo de este manuscrito es hacer una revisión de las consideraciones técnicas, de las principales aplicaciones clínicas y direcciones futuras de la CBCT en radiología vascular e intervencionista y en neurorradiología intervencionista.

Palabras clave:
Tomografía computarizada de haz cónico
Radiología intervencionista
Procedimientos endovasculares
Embolización
Ablación

Article

These are the options to access the full texts of the publication Radiología (English Edition)
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
References
[1]
R.C. Orth, M.J. Wallace, M.D. Kuo.
Radiology TACotSoI. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology.
J Vasc Interv Radiol., 20 (2009), pp. S538-44
[2]
K.M. Wong, B.S. Tan, M. Taneja, S.Y. Wong, J.S. Loke, S.E. Lin, et al.
Cone beam computed tomography for vascular interventional radiology procedures: early experience.
Ann Acad Med Singap., 40 (2011), pp. 308-314
[3]
J.B. Hinrichs, S. Marquardt, C. von Falck, M.M. Hoeper, K.M. Olsson, F.K. Wacker, et al.
Comparison of C-arm computed tomography and digital subtraction angiography in patients with chronic thromboembolic pulmonary hypertension.
Cardiovasc Intervent Radiol., 39 (2016), pp. 53-63
[4]
M.J. Wallace, M.D. Kuo, C. Glaiberman, C.A. Binkert, R.C. Orth, G. Soulez, et al.
Three-dimensional C-arm cone-beam CT: applications in the interventional suite.
J Vasc Interv Radiol., 20 (2009), pp. S523-37
[5]
Y.M. Kwok, F.G. Irani, K.H. Tay, C.C. Yang, C.G. Padre, B.S. Tan.
Effective dose estimates for cone beam computed tomography in interventional radiology.
Eur Radiol., 23 (2013), pp. 3197-3204
[6]
M. Jonczyk, F. Collettini, D. Geisel, D. Schnapauff, G. Böning, G. Wieners, et al.
Radiation exposure during TACE procedures using additional cone-beam CT (CBCT) for guidance: safety and precautions.
Acta Radiol., 59 (2018), pp. 1277-1284
[7]
R. Pauwels.
What Is CBCT and How Does It Work?.
Maxillofacial Cone Beam Computed Tomography: Principles, Techniques and Clinical Applications, pp. 13-42
[8]
R. Pauwels, K. Araki, J.H. Siewerdsen, S.S. Thongvigitmanee.
Technical aspects of dental CBCT: state of the art.
Dentomaxillofac Radiol., 44 (2015),
[9]
H. de LasHerasGala, A. Torresin, A. Dasu, O. Rampado, H. Delis, et al.
Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report).
Phys Med., 39 (2017), pp. 67-72
[10]
J. Iwazawa, S. Ohue, N. Hashimoto, O. Muramoto, T. Mitani.
Survival after C-arm CT-assisted chemoembolization of unresectable hepatocellular carcinoma.
Eur J Radiol., 81 (2012), pp. 3985-3992
[11]
P. Lucatelli, M. Burrel, B. Guiu, G. de Rubeis, O. van Delden, T. Helmberger.
CIRSE standards of practice on hepatic transarterial chemoembolisation.
Cardiovasc Intervent Radiol., 44 (2021), pp. 1851-1867
[12]
L. Pung, M. Ahmad, K. Mueller, J. Rosenberg, C. Stave, G.L. Hwang, et al.
The role of cone-beam CT in transcatheter arterial chemoembolization for hepatocellular carcinoma: a systematic review and meta-analysis.
J Vasc Interv Radiol., 28 (2017), pp. 334-341
[13]
J. Iwazawa, S. Ohueo, N. Hashimoto, T. Mitani.
Feasibility of using vessel-detection software for the endovascular treatment of visceral arterial bleeding.
Diagn Interv Radiol., 20 (2014), pp. 160-163
[14]
U. Grosse, R. Syha, D. Ketelsen, R. Hoffmann, S. Partovi, T. Mehra, et al.
Cone beam computed tomography improves the detection of injured vessels and involved vascular territories in patients with bleeding of uncertain origin.
Br J Radiol., 91 (2018),
[15]
G. Carrafiello, A.M. Ierardi, E. Duka, A. Radaelli, C. Floridi, A. Bacuzzi, et al.
Usefulness of cone-beam computed tomography and automatic vessel detection software in emergency transarterial embolization.
Cardiovasc Intervent Radiol., 39 (2016), pp. 530-537
[16]
E. Serrano, F. Zarco, A.E. Gill, C.M. Hawkins, N. Macías, E.J. Inarejos Clemente, et al.
Percutaneous cryoablation of chondroblastoma and osteoblastoma in pediatric patients.
Insights Imaging., 12 (2021), pp. 106
[17]
R.L. Cazzato, J.B. Battistuzzi, V. Catena, R.F. Grasso, B.B. Zobel, E. Schena, et al.
Cone-Beam Computed Tomography (CBCT) versus CT in lung ablation procedure: which is faster?.
Cardiovasc Intervent Radiol., 38 (2015), pp. 1231-1236
[18]
L. van Bindsbergen, S.J. Braak, M.J. van Strijen, J.P. de Vries.
Type II endoleak embolization after endovascular abdominal aortic aneurysm repair with use of real-time three-dimensional fluoroscopic needle guidance.
J Vasc Interv Radiol., 21 (2010), pp. 1443-1447
[19]
İ Yildirim, T. Pişkin, E. Duman, A. Firat, M. Dogan, H. Taskapan, et al.
A novel technique in the treatment of lymphoceles after renal transplantation: C-arm cone beam CT-guided percutaneous embolization of lymphatic leakage after lymphangiography.
Transplantation., 102 (2018), pp. 1955-1960
[20]
K. Lagios, G. Karaolanis, T. Bazinas, T. Perdikides, I. Bountouris.
Translumbar Infusion of N-Butyl Cyanoacrylate for the Treatment of Type II Endoleaks.
J Vasc Interv Radiol., 29 (2018), pp. 826-832
[21]
L. Monfardini, N. Gennaro, F. Orsi, P. Della Vigna, G. Bonomo, G. Varano, et al.
Real-time US/cone-beam CT fusion imaging for percutaneous ablation of small renal tumours: a technical note.
Eur Radiol., 31 (2021), pp. 7523-7528
[22]
S.R. Goudeketting, S.G.H. Heinen, Ç Ünlü, D.A.F. van den Heuvel, J.P.M. de Vries, M.J. van Strijen, et al.
Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis.
J Endovasc Ther, 24 (2017), pp. 595-603
[23]
T. Ogo, T. Fukuda, A. Tsuji, S. Fukui, J. Ueda, Y. Sanda, et al.
Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography.
Eur J Radiol., 89 (2017), pp. 270-276
[24]
J.L. Lin, H.M. Chen, F.C. Lin, J.Y. Li, C.X. Xie, W.L. Guo, et al.
Application of DynaCT angiographic reconstruction in balloon pulmonary angioplasty.
Eur Radiol., 30 (2020), pp. 6950-6957
[25]
T. Matsushige, Y. Hashimoto, T. Ogawa, G. Makimoto, M. Yoshiyama, T. Hara, et al.
The impact of high-resolution cone-beam CT findings on decision-making for the treatment of unruptured middle cerebral artery aneurysms.
Neurosurg Rev., 46 (2022), pp. 26
[26]
E. Raz, E. Nossek, D.H. Sahlein, V. Sharashidze, V. Narayan, A. Ali, et al.
Principles, techniques and applications of high resolution cone beam CT angiography in the neuroangio suite.
J Neurointerv Surg., 15 (2022), pp. 600-607
[27]
D. Simonato, S. Gargalas, P.J. Cox, V. Young, R. Corkill, W. Kuker, et al.
Aneurysms of the communicating segment of the internal carotid artery with posterior communicating artery agenesis are associated with perforator infarction after embolization.
J Neurointerv Surg., 13 (2021), pp. 347-352
[28]
Y. Hashimoto, T. Matsushige, T. Ogawa, H. Sakuragouchi, K. Shimonaga, H. Takahashi, et al.
Impact of cone-beam computed tomography angiography on visualization of Sylvian veins.
World Neurosurg., 143 (2020), pp. e206-e214
[29]
H. Matsukawa, H. Kamiyama, T. Miyazaki, Y. Kinoshita, N. Ota, K. Noda, et al.
Comprehensive analysis of perforator territory infarction on postoperative diffusion-weighted imaging in patients with surgically treated unruptured intracranial saccular aneurysms.
J Neurosurg., 132 (2019), pp. 1088-1095
[30]
V.M. Srinivasan, S. Schafer, M.G. Ghali, A. Arthur, E.A. Duckworth.
Cone-beam CT angiography (Dyna CT) for intraoperative localization of cerebral arteriovenous malformations.
J Neurointerv Surg., 8 (2016), pp. 69-74
[31]
A.S. Al-Smadi, A. Elmokadem, A. Shaibani, M.C. Hurley, M.B. Potts, B.S. Jahromi, et al.
Adjunctive efficacy of intra-arterial conebeam CT Angiography relative to DSA in the diagnosis and surgical planning of micro-arteriovenous malformations.
AJNR Am J Neuroradiol., 39 (2018), pp. 1689-1695
[32]
H. Hasegawa, S. Hanakita, M. Shin, M. Kawashima, T. Kin, W. Takahashi, et al.
Integrating 3D rotational angiography into gamma knife planning.
AJNR Am J Neuroradiol., 39 (2018), pp. 1867-1870
[33]
H. Hasegawa, S. Hanakita, M. Shin, M. Kawashima, T. Kin, W. Takahashi, et al.
Integration of rotational angiography enables better dose planning in Gamma Knife radiosurgery for brain arteriovenous malformations.
J Neurosurg., 129 (2018), pp. 17-25
[34]
I.M. van der Bom, M.J. Gounis, L. Ding, A.L. Kühn, D. Goff, A.S. Puri, et al.
Target delineation for radiosurgery of a small brain arteriovenous malformation using high-resolution contrast-enhanced cone beam CT.
J Neurointerv Surg., 6 (2014), pp. e34
[35]
K. Kadooka, M. Tanaka, Y. Sakata, M. Ideguchi, M. Inaba, H. Hadeishi.
Efficacy of cone beam computed tomography in treating cavernous sinus dural arteriovenous fistula.
World Neurosurg., 109 (2018), pp. 328-332
[36]
M. Tanaka.
Embryological consideration of dural AVF.
Acta Neurochir Suppl., 123 (2016), pp. 169-176
[37]
M. Shapiro, M. Walker, K.T. Carroll, M.R. Levitt, E. Raz, E. Nossek, et al.
Neuroanatomy of cranial dural vessels: implications for subdural hematoma embolization.
J Neurointerv Surg., 13 (2021), pp. 471-477
[38]
K. Yoshida, T. Akiyama, S. Takahashi, T. Miwa, T. Horiguchi, H. Sasaki, et al.
Cone-beam computed tomography fusion technique for vascular assessment of skull base meningiomas.
World Neurosurg., 151 (2021), pp. 61-69
[39]
T.D. Aadland, K.R. Thielen, T.J. Kaufmann, J.M. Morris, G. Lanzino, D.F. Kallmes, et al.
3D C-arm conebeam CT angiography as an adjunct in the precise anatomic characterization of spinal dural arteriovenous fistulas.
AJNR Am J Neuroradiol., 31 (2010), pp. 476-480
[40]
V. Tacher, A. Radaelli, M. Lin, J.F. Geschwind.
How I do it: cone-beam CT during transarterial chemoembolization for liver cancer.
Radiology., 274 (2015), pp. 320-334
[41]
J.B. Hinrichs, C. von Falck, M.M. Hoeper, K.M. Olsson, F.K. Wacker, B.C. Meyer, et al.
Pulmonary artery imaging in patients with chronic thromboembolic pulmonary hypertension: comparison of cone-beam CT and 64-row multidetector CT.
J Vasc Interv Radiol., 27 (2016), pp. 361-368.e2
[42]
M. Humbert, G. Kovacs, M.M. Hoeper, R. Badagliacca, R.M.F. Berger, M. Brida, et al.
2022 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension.
Eur Respir J., 61 (2023),
[43]
T. Fukuda, T. Ogo, N. Nakanishi, J. Ueda, Y. Sanda, Y. Morita, et al.
Evaluation of organized thrombus in distal pulmonary arteries in patients with chronic thromboembolic pulmonary hypertension using cone-beam computed tomography.
Jpn J Radiol., 34 (2016), pp. 423-431
[44]
S.K. Maschke, J.B. Hinrichs, J. Renne, T. Werncke, H.M.B. Winther, K.I. Ringe, et al.
C-Arm computed tomography (CACT)-guided balloon pulmonary angioplasty (BPA): evaluation of patient safety and peri- and post-procedural complications.
Eur Radiol, 29 (2019), pp. 1276-1284
[45]
R.E. Schernthaner, R.R. Haroun, R. Duran, H. Lee, S. Sahu, J.H. Sohn, et al.
Improved visibility of metastatic disease in the liver during intra-arterial therapy using delayed arterial phase cone-beam CT.
Cardiovasc Intervent Radiol., 39 (2016), pp. 1429-1437
[46]
P.J. O’Connor, S.D. Pasik, I.M. van der Bom, V. Bishay, A. Radaelli, E. Kim.
Feasibility of yttrium-90 radioembolization dose calculation utilizing intra-procedural open trajectory cone beam CT.
Cardiovasc Intervent Radiol., 43 (2020), pp. 295-301
[47]
M. Rodríguez-Fraile, A. Ezponda, F. Grisanti, V. Morán, M. Calvo, P. Berián, et al.
The joint use of.
[48]
F. Diana, E. Raz, F. Biraschi, D.G. Romano, G. Toccaceli, M. Shapiro, et al.
Cone-beam CT angiography to assess the microvascular anatomy of intracranial arterial dissections.
Neuroradiol J., 35 (2022), pp. 527-532
[49]
D. Simonato, R.J. Borchert, F. Vallee, J. Joachim, V. Civelli, L. Cancian, et al.
Distribution of symptomatic cerebral vasospasm following subarachnoid hemorrhage assessed using cone-beam CT angiography.
J Neurointerv Surg., 14 (2022), pp. 1107-1111
[50]
H.H. Yen, C. Chien, I.H. Lee, S.P. Chen, C.B. Luo, C.J. Lin, et al.
Application of flat-panel volume computed tomography to evaluate cerebral hemorrhage after mechanical thrombectomy of acute embolic stroke of the anterior circulation.
J Comput Assist Tomogr., 45 (2021), pp. 919-925
[51]
P. Nicholson, N.M. Cancelliere, J. Bracken, E. Hummel, F. van Nijnatten, P. Withagen, et al.
Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: a prospective study.
Eur J Radiol, 138 (2021),
[52]
S. Ortega-Gutierrez, D. Quispe-Orozco, S. Schafer, M. Farooqui, C.B. Zevallos, S. Dandapat, et al.
Angiography suite cone-beam CT perfusion for selection of thrombectomy patients: a pilot study.
J Neuroimaging., 32 (2022), pp. 493-501
[53]
P. Yang, K. Niu, Y. Wu, T. Struffert, A. Doerfler, P. Holter, et al.
Evaluation of collaterals and clot burden using time-resolved C-arm conebeam CT angiography in the angiography suite: a feasibility study.
AJNR Am J Neuroradiol., 38 (2017), pp. 747-752
[54]
R.S. Heller, A.M. Malek.
Successful detection of embologenic ulceration in a symptomatic non-hemodynamic intracranial stenosis using C-arm cone beam CT.
J Neurointerv Surg., 5 (2013), pp. e3
[55]
J. Dong, X. Bai, A.A. Dmytriw, L. Xuan, T. Wang, X. Lu, et al.
Identification of carotid artery microstructure and plaque rupture using C-arm cone-beam CT: a case report.
Front Neurol., 12 (2021),
[56]
B. Sangro, D. Martínez-Urbistondo, L. Bester, J.I. Bilbao, D.M. Coldwell, P. Flamen, et al.
Prevention and treatment of complications of selective internal radiation therapy: Expert guidance and systematic review.
Hepatology., 66 (2017), pp. 969-982
[57]
N. Hafezi-Nejad, D.M. Gullotti, C.R. Bailey, M.L. Lessne, B.P. Holly.
Does intraprocedural CT improve the success rate of adrenal venous sampling? A systematic review and meta-analysis of data from 809 patients.
Cardiovasc Intervent Radiol., 45 (2022), pp. 29-40
[58]
R. Cai, C. Hu, H.Y. Li.
Cone-beam computed tomography is not a mandatory procedure in adrenal venous sampling for primary hyperaldosteronism.
BMC Med Imaging., 22 (2022), pp. 189
[59]
T. Leger, A. Petit, Y. Moustarhfir, Y. Ajavon, N. Sellier, O. Seror, et al.
Use of virtual target fluoroscopic display of three-dimensional CO.
Cardiovasc Intervent Radiol., 44 (2021), pp. 1817-1822
[60]
F. Bürckenmeyer, I. Diamantis, T. Kriechenbauer, T. Lehmann, T. Franiel, A. Malouhi, et al.
Prostatic artery embolization: influence of cone-beam computed tomography on radiation exposure, procedure time, and contrast media use.
Cardiovasc Intervent Radiol., 44 (2021), pp. 1089-1094
[61]
V. Lefournier, M. Martinie, A. Vasdev, P. Bessou, J.G. Passagia, F. Labat-Moleur, et al.
Accuracy of bilateral inferior petrosal or cavernous sinuses sampling in predicting the lateralization of Cushing’s disease pituitary microadenoma: influence of catheter position and anatomy of venous drainage.
J Clin Endocrinol Metab., 88 (2003), pp. 196-203
[62]
L. Andereggen, J. Gralla, G. Schroth, P. Mordasini, R.H. Andres, H.R. Widmer, et al.
Influence of inferior petrosal sinus drainage symmetry on detection of adenomas in Cushing’s syndrome.
J Neuroradiol., 48 (2021), pp. 10-15
[63]
A.N. Mamelak, C.F. Dowd, J.B. Tyrrell, J.F. McDonald, C.B. Wilson.
Venous angiography is needed to interpret inferior petrosal sinus and cavernous sinus sampling data for lateralizing adrenocorticotropin-secreting adenomas.
J Clin Endocrinol Metab., 81 (1996), pp. 475-481
[64]
A. Deipolyi, A. Bailin, J.A. Hirsch, T.G. Walker, R. Oklu.
Bilateral inferior petrosal sinus sampling: experience in 327 patients.
J Neurointerv Surg., 9 (2017), pp. 196-199
[65]
K. Bannangkoon, K. Hongsakul, T. Tubtawee, T. Piratvisuth.
Safety margin of embolized area can reduce local recurrence of hepatocellular carcinoma after superselective transarterial chemoembolization.
Clin Mol Hepatol., 25 (2019), pp. 74-85
[66]
S.J. Braak, G.J. Herder, J.P. van Heesewijk, M.J. van Strijen.
Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy.
Cardiovasc Intervent Radiol., 35 (2012), pp. 1414-1421
[67]
F. Clarençon, F. Di Maria, J. Gabrieli, E. Shotar, V. Degos, A. Nouet, et al.
Clinical impact of flat panel volume CT angiography in evaluating the accurate intraoperative deployment of flow-diverter stents.
AJNR Am J Neuroradiol., 38 (2017), pp. 1966-1972
[68]
T. Struffert, M. Saake, S. Ott, T. Engelhorn, P. Gölitz, S. Kloska, et al.
Intravenous flat detector CT angiography for non-invasive visualisation of intracranial flow diverter: technical feasibility.
Eur Radiol., 21 (2011), pp. 1797-1801
[69]
G. Faragò, V. Caldiera, C. Antozzi, A. Bellino, A. Innocenti, E. Ciceri.
Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation.
Eur Radiol., 27 (2017), pp. 2200-2205
asdasdasd
Article options
Tools