Buscar en
Archivos de la Sociedad Española de Oftalmología
Toda la web
Inicio Archivos de la Sociedad Española de Oftalmología Análisis de nervios estromales en pacientes con queratocono
Información de la revista
Vol. 89. Núm. 8.
Páginas 308-312 (Agosto 2014)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1512
Vol. 89. Núm. 8.
Páginas 308-312 (Agosto 2014)
Artículo original
Análisis de nervios estromales en pacientes con queratocono
Comparison of stromal corneal nerves between normal and keratoconus patients using confocal microscopy
Visitas
1512
M. Ramírez Fernández
Autor para correspondencia
, E. Hernández Quintela, R. Naranjo Tackman
Servicio de Córnea y Cirugía Refractiva, Asociación Para Evitar la Ceguera en México (APEC), Hospital Luis Sánchez Bulnes, Universidad Nacional Autónoma de México, México D.F., México
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Resumen
Objetivo

Evaluar las diferencias de los nervios del estroma de la córnea entre sujetos normales y pacientes con queratocono.

Métodos

Un total de 140 ojos de 70 sujetos normales (grupo A) y 122 ojos de 87 pacientes con queratocono (grupo B), fueron evaluados con el microscopio confocal, realizando un rastreo central del espesor total de la córnea. La morfología y el espesor de los nervios fueron evaluados utilizando el programa Navis v. 3.5.0. El espesor de los nervios se obtuvo del promedio de la porción más delgada y la más gruesa de cada nervio.

Resultados

Los nervios del estroma se observaron como estructuras lineales de alta reflexión e irregulares, con porciones gruesas y angostas en todos los casos. El promedio del espesor de los nervios en el grupo A fue de 5,7±1,7 (rango de 3,3 a 10,4 μ), en el grupo B fue de 7,2±1,9 (rango de 3,5 a 12,0 μ). La diferencia en el espesor de los nervios entre el grupo A y el grupo B fue estadísticamente significativa (p<0,05).

Conclusiones

La morfología de los nervios del estroma de la córnea fue similar en ambos grupos; el espesor de estos fue mayor en los pacientes con queratocono.

Palabras clave:
Córnea
Estroma
Queratocono
Nervios
Confocal
Abstract
Objective

To evaluate the differences in stromal corneal nerves between normal patients and keratoconus patients.

Material and methods

A total of 140 eyes of 70 normal patients (group A) and 122 eyes of 87 keratoconus patients (group B) were examined with the confocal microscope, with a central scan of the total corneal thickness being taken. The morphology and thickness of the corneal stromal nerves were evaluated by using the Navis v. 3.5.0. software. Nerve thickness was obtained from the mean between the widest and the narrowest portions of each stromal nerve.

Results

Corneal stromal nerves were observed as irregular linear hyper-reflective structures with wide and narrow portions in all cases. Mean corneal stromal nerves thickness in group A was 5.7±1.7 (range from 3.3 to 10.4 μ), mean corneal stromal nerves thickness in group B was 7.2±1.9 (range from 3.5 to 12.0 μ). There was a statistical significant difference (P<.05) in stromal corneal nerves thickness between group A and group B.

Conclusion

Stromal corneal nerves morphology was similar in both groups, but stromal nerves were thicker in keratoconus patients.

Keywords:
Cornea
Stromal
Keratoconus
Nerves
Confocal

Artículo

Opciones para acceder a los textos completos de la publicación Archivos de la Sociedad Española de Oftalmología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Archivos de la Sociedad Española de Oftalmología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos