metricas
Acta Otorrinolaringológica Española Tinnitus Measurement With Conventional Audiometer Versus High-frequency Audiomet...
Journal Information
Vol. 63. Issue 2.
Pages 79-164 (March - April 2012)
Cite
Cite
Share
Download PDF
More article options
Visits
2799
Vol. 63. Issue 2.
Pages 79-164 (March - April 2012)
Original article

Tinnitus Measurement With Conventional Audiometer Versus High-frequency Audiometer

Medición de acúfenos con audiómetro convencional versus audiómetro de alta frecuencia
Visits
2799
Miguel A. López-Gonzáleza,
Corresponding author
malopez@cica.es

Corresponding author.
, Esther Cambilb, Antonio Abrantea, Rocío López-Fernándezb, Elizabeth Bareab, Francisco Estebana
a UGC Otorrinolaringología, Hospital Universitario Virgen del Rocío, Sevilla, Spain
b Centro Integral de Acúfenos, Sevilla, Spain
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Abstract
Introduction and objectives

Determinations of the psychoacoustic characteristics of tinnitus (frequency and intensity) are valid for diagnosis, treatment, monitoring and research purposes. The aim of this work is to compare the frequency of the tinnitus measured with a standard audiometer and a high frequency audiometer.

Methods

We used a conventional audiometer (frequency range: 125–12000Hz) and a high-frequency audiometer (frequency range: 125–18000Hz) to measure the frequency and intensity of tinnitus in 47 patients with tinnitus as a continuous ringing.

Results

We found statistically significant differences between the determination of the frequency of tinnitus made with conventional and high-frequency audiometers, as well as a correlation between high-frequency tinnitus and distress expressed by patients.

Conclusions

(1) The frequency of tinnitus determined by high-frequency audiometer is greater than the frequency determined by conventional audiometer; (2) the higher the frequency of tinnitus, the more discomfort the patient manifests; and (3) there is no relationship between the intensity and discomfort caused by tinnitus.

Keywords:
Tinnitus
Audiometer
High-frequency
Visual analogical scale
Resumen
Introducción y objetivos

Las determinaciones de las características psicoacústicas del acúfeno (frecuencia e intensidad) son válidas para el diagnóstico, tratamiento, seguimiento y fines de investigación. El objetivo de este estudio es conocer si se encuentran diferencias entre las determinaciones de la frecuencia e intensidad del acúfeno con metodología convencional o metodología de alta frecuencia.

Métodos

Se utiliza audiómetro convencional (rango de frecuencias: 125-12.000Hz) y audiómetro de alta frecuencia (rango de frecuencias: 125-18.000Hz) para medir la frecuencia e intensidad de los acúfenos en 47 pacientes con acúfenos continuos en forma de pitidos.

Resultados

Se han encontrado diferencias estadísticamente significativas entre las determinaciones de la frecuencia del acúfeno efectuadas con audiómetro convencional y audiómetro de alta frecuencia, así como correlación entre los acúfenos de alta frecuencia y las molestias manifestadas por los pacientes.

Conclusiones

1) La frecuencia del acúfeno determinada con audiómetro de alta frecuencia es mayor que la frecuencia determinada con audiómetro convencional; 2) cuanto mayor es la frecuencia del acúfeno, más molestias manifiesta el paciente; y 3) no hay relación entre la intensidad y la molestia producida por el acúfeno.

Palabras clave:
Acúfeno
Tinnitus
Audiómetro
Alta frecuencia
Escala analógica visual

Article

These are the options to access the full texts of the publication Acta Otorrinolaringológica Española
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
References
[1]
Ciba Foundation.
Tinnitus.
CIBA Foundation Symposium, vol. 85,
[2]
E.P. Fowler.
Head noises in normal and disordered ear.
Arch Otolaryngol, 39 (1944), pp. 498-503
[3]
H. Feldman.
Homolateral and contralateral masking of tinnitus by noise bands and by pure tones.
Audiology, 10 (1911), pp. 138-144
[4]
J. Vernon.
Relief of tinnitus by masking Treatment.
Otolaryngology,
[5]
J. Doménech Oliva, M. Carulla París.
Examen del paciente con acúfenos.
Acta Otorrinolaringol Esp, 39 (1988), pp. 145-149
[6]
M.V. González Méndez, M. Sainz Quevedo, R. Ruiz-Rico Ruiz.
Enmascaramiento acústico y curvas de Feldman en acúfenos.
Acta Otorrinolaringol Esp, 47 (1996), pp. 438-440
[7]
B. Bhathal, E. Alonso Tomás, M. Pérez Carretero, J. Poch Broto.
Estudio clínico-epidemiológico de acúfenos en el ámbito de la atención ambulatoria.
Acta Otorrinolaringol Esp, 49 (1998), pp. 609-613
[8]
C. Herráiz.
Mecanismos fisiopatológicos en la generación y persistencia de los acúfenos.
Acta Otorrinolaringol Esp, 56 (2005), pp. 335-342
[9]
I. Romero Sánchez, H. Pérez Garrigues, V. Rodríguez Rivera.
Características clínicas de los acúfenos en la enfermedad de Ménière.
Acta Otorrinolaringol Esp, 61 (2010), pp. 327-331
[10]
F. Hernández Moñiz, A. Barrio, A. Pérez, M.A. Pertierra, J.M. Salafranca, M. González.
Ensayo terapéutico prospectivo del tratamiento de enmascaramiento en pacientes con acúfenos.
Acta Otorrinolaringol Esp, 49 (1998), pp. 437-441
[11]
M.A. López González, M.L. Muratori León, J. Moreno Vaquera.
Sulpirida como tratamiento inicial en la terapia de reentrnamiento de acúfenos.
Acta Otorrinolaringol Esp, 54 (2003), pp. 237-241
[12]
M.A. López González, R. López Fernández.
Terapia sonora secuencial en acúfenos.
Acta Otorrinolaringol Esp, 55 (2004), pp. 2-8
[13]
C. Herráiz, J. Hernández Calvín, G. Plaza, M.C. Tapia, G. de los Santos.
Evaluación de la discapacidad en pacientes con acúfenos.
Acta Otorrinolaringol Esp, 52 (2001), pp. 534-538
[14]
A. Peña Martínez.
Evaluación de la incapacidad provocada por el tinnitus: homologación lingüística nacional del Tinnitus Handicap Inventory (THI).
Rev Otorrinolaringol Cir Cabeza Cuello, 66 (2006), pp. 232-235
[15]
E.P. Fowler.
The illusion of loudness of tinnitus its etiology and treatment.
Laryngoscope, 52 (1942), pp. 275-285
[16]
B. Cuda, P. Brizzi, B. Luppi.
Misurazioni psi-coacustiche (acufenometria).
Acufeni: diagnosi e terapia, pp. 97-105
[17]
E. Cambil, R. López-Fernández, E. Barea, F. Esteban.
Acúfeno como señal de malestar. Capítulo 16, 9788469233672, pp. 231-242
[18]
D.S. Choy, R.A. Lipman, G.P. Tassi.
Worldwide experience with sequential phase-shift sound cancellation treatment of predominant tone tinnitus.
J Laryngol Otol, 13 (2010), pp. 1-4
asdasdasd
Article options
Tools