Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Rendimiento diagnóstico de la gammagrafía ósea y la PET/TAC con 11C-colina en...
Información de la revista
Vol. 34. Núm. 3.
Páginas 155-161 (Mayo - Junio 2015)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
2484
Vol. 34. Núm. 3.
Páginas 155-161 (Mayo - Junio 2015)
Original
Rendimiento diagnóstico de la gammagrafía ósea y la PET/TAC con 11C-colina en la detección de metástasis óseas en pacientes con recidiva bioquímica de cáncer de próstata
Diagnostic performance of bone scintigraphy and 11C-Choline PET/CT in the detection of bone metastases in patients with biochemical recurrence of prostate cancer
Visitas
2484
J.R. Garcia
Autor para correspondencia
jrgarcia@cetir.es

Autor para correspondencia.
, C. Moreno, E. Valls, P. Cozar, P. Bassa, M. Soler, F.J. Alvarez-Moro, M. Moragas, E. Riera
Unidad PET CETIR-ERESA, Esplugues, Barcelona, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (3)
Tabla 1. Pacientes con discordancia total entre la detección de metástasis óseas con gammagrafía ósea y PET/TC con 11C-colina
Tabla 2. Correspondencia morfológica de las lesiones metastásicas óseas detectadas en la gammagrafía ósea
Tabla 3. Correspondencia morfológica de las lesiones metastásicas óseas detectadas en la PET/TC con 11C-colina
Mostrar másMostrar menos
Resumen
Objetivo

Comparamos la gammagrafía ósea (GO) y la 11C-colina-PET/TAC en la detección de metástasis óseas en pacientes con recidiva bioquímica de cáncer de próstata (CaP).

Material y métodos

Ciento sesenta y nueve pacientes que acudieron para realizar ambas exploraciones (0-15 días) por recidiva bioquímica (PSA: 2,4-58ng/ml) de CaP. Analizamos la tasa de detección de GO y 11C-colina-PET/TAC por pacientes y lesiones. El diagnóstico de metástasis se realizó por: biopsia, confirmación TAC/18F-fluoruro PET/RM, progresión por técnicas de imagen.

Resultados

Noventa y una lesiones captantes mediante GO y/o 11C-colina-PET/TAC (40 pacientes), 78 de ellas metastásicas.

GO detectó 38 blásticas, 2 líticas y 10 sin traducción-TAC. 11C-colina-PET/TAC: 41 blásticas, 4 líticas y 29 sin traducción-TAC. La sensibilidad de GO y 11C-colina-PET/TAC fue del 65,4 y 96,1%; la especificidad del 38,5 y 92,3% (χ2 8,27, p<0,04).

En 118 pacientes ambas exploraciones fueron negativas. En 51 pacientes mostraron lesiones captantes: 30/51 GO y 11C-colina-PET/TAC concordantes. En 21/51 mostraron lesiones discordantes (kappa 0,712, p=0,00).

En 10/19 pacientes la discordancia fue total: 5 FN GO, 2 FP GO (degenerativa; displasia), uno FN 11C-colina-PET/TAC (blástica), uno FP 11C-colina-PET/TAC (degenerativa), uno fuera campo 11C-colina-PET/TAC (tibial única).

11C-colina PET/TAC detectó enfermedad extraósea en 26/51 pacientes con metástasis óseas: 9 local, 5 adenopatías infradiafragmáticas, 2 supradiafragmáticas, 5 local e infradiafragmática, 4 infra y supradiafragmáticas, una supradiafragmáticas y metástasis pulmonares.

Conclusión

La 11C-colina-PET/TAC muestra una mayor sensibilidad y especificidad que la GO en la detección de metástasis óseas en pacientes con recidiva bioquímica de CaP. Además, permite la reestadificación extraósea, con impacto en el manejo de estos pacientes.

Palabras clave:
Gammagrafía ósea
11C-colina PET/TAC
Metástasis óseas
Recidiva bioquímica
Cáncer de próstata
Abstract
Aim

To compare bone scan (BS) with 11C-Choline PET/CT for the detection of bone metastases in patients with biochemical recurrence of prostate cancer (PC).

Material and Methods

A total of 169 patients with biochemical recurrence of PC(PSA:2.4-58 ng/ml) who were referred for both exams (0-15 days-in-between) were included. Lesion-detection-rate per patients and lesions were analyzed for both BS and 11C-Choline PET/CT. Metastasis diagnosis was reached by: biopsy, CT/18F-Fluoride PET/MRI confirmation, or evidence of progression in subsequent imaging procedures.

Results

A total of 91 lesions were found to be active in BS and/or 11C-choline PET/CT (40 patients), with 78 of which were metastatic.

BS detected 38 blastic, 2 lytic and 10 non-CT-evident lesions. 11C-Choline PET/CT detected 41 blastic, 4 lytic and 29 non-CT-evident lesions. BS and 11C-Choline PET/CT sensitivities were 65.4% and 96.1%; specificities ere 38.5 and 92.3% (χ2 8.27, p<0.04).

Both imaging techniques were negative in 118 patients. Tracer avid lesions were found in 51 patients: with 30/51 being BS and 11C-Choline PET/CT concordant; in 21/51 patients had discordant lesions (kappa 0.712, p=0.00).

Lesions were absolutely discordant in 10/19 patients,: 5 FN BS, 2 FP BS (degenerative changes; dysplasia), 1 FN 11C-Choline PET/CT (blastic), 1 FP 11C-Choline PET/CT (degenerative), 1 out of field-of-view lesion with 11C-Choline PET/CT (tibia alone).

11C-Choline PET/CT showed extraosseous involvement in 26/51 patients with bone metastases: 9 local recurrences, 5 infra-diaphragmatic-lymph-nodes, 2 supra-diaphragmatic, 5 local and infra-diaphragmatic, 4 infra- and supra-diaphragmatic, 1 supra-diaphragmatic and lung metastases.

Conclusion

11C-Choline PET/CT yielded better sensitivity and specificity than BS for the detection of bone involvement in patients with biochemical recurrence of PC and allowed extraosseous restaging, with an impact in the clinical management of these patients.

Keywords:
Bone scintigraphy
11C-Choline PET/CT
Bone metastases
Biochemical recurrence
Prostate cancer

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos