Efectos de la electrolisis percutánea en el tendón rotuliano sobre la temperatura local y contralateral medida con termografía infrarroja
Effects of percutaneous needle electrolysis in patellar tendon on local and contralateral temperature measure with infrared thermography
Visitas
...
Óscar Carvajal Fernándeza, David Álvarez Pratsa, Francesc Medina i Mirapeixb, Francisco Minaya Muñozc
a Cl??nica Fisioterapia Oc??ano, Madrid, Espa??a
b Departamento de Fisioterapia, Universidad de Murcia, Murcia, Espa??a
c MVClinic, Madrid, Espa??a; Facultad de Medicina, Universidad San Pablo CEU, Madrid, Espa??a
Información del artículo

Objetivos: Valorar el efecto que tiene la aplicación de la técnica de electrolisis percutánea musculoesquelética en el tendón rotuliano sobre la modificación del flujo sanguíneo cutáneo de la rodilla intervenida y su contralateral a lo largo de los 30 minutos posteriores a la aplicación.
Material y métodos: Se realizó un estudio experimental no aleatorizado con dos grupos de sujetos voluntarios: grupo electrolisis (n = 19) y grupo control (n = 14). Se realizaron tomas de imágenes termográficas del área de ambas rodillas en cuatro tiempos diferentes (antes de la intervención, inmediatamente después de la intervención, a los 15 minutos y a los 30 minutos).
También se valoró la sensación subjetiva de dolor percibido mediante la escala analógica visual y la actitud de miedo-aprehensión.
Resultados: Tras la aplicación del procedimiento en el tendón rotuliano, se observaron cambios térmicos en el grupo electrolisis con un patrón de comportamiento no homogéneo, también se observaron cambios en la rodilla contralateral a la intervenida de características similares a la rodilla sometida a intervención.
Discusión: Los cambios térmicos que se producen en el grupo electrolisis tanto en la rodilla intervenida como en la contralateral sólo pueden explicarse por mecanismos neurológicos periféricos y centrales.
Conclusiones: La técnica de la electrolisis percutánea musculoesquelética en el tendón rotuliano produce cambios térmicos mediados por mecanismos centrales, tanto en el área cutánea de la rodilla de aplicación como en la contralateral. Los patrones de respuesta obtenidos, a pesar de ser heterogéneos, están condicionados por el estado patológico del tendón y la aprehensión mostrada durante la intervención.

Palabras clave:
Electrolisis percutánea musculoesquelética; Termografía infrarroja; Circulación cutánea

Objectives: Assess the effect of the application of the technique of percutaneous needle electrolysis in the patellar tendon on the modification of cutaneous blood flow of the intervention knee and contralateral over 30 minutes after application.
Material and Methods: An experimental study non-randomized was carried out, consisting of two groups: electrolysis group (n = 19) and control group (n = 14). The thermographic images were performed in the area of both knees in four different intervals of time: pre-intervention, immediate, fifteen minutes and thirty minutes post-intervention. The subjective feeling of perceived pain by visual analogue scale and the attitude of fear-apprehension are also assessed.
Results: After application of the procedure in the patellar tendon, thermal changes were observed in the electrolysis group with a pattern of no homogeneous behavior, changes were also observed in the contralateral knee similar to intervention knee.
Discussion: Thermal changes that occur in the electrolysis group in both knees, intervention and contralateral, only can be explained by peripheral and central neurological mechanisms.
Conclusions: Percutaneous needle electrolysis in the patellar tendon produces thermal changes through central mechanisms, both on the cutaneous area of the intervention knee and in the contralateral. Response patterns obtained, despite being heterogeneous, are conditioned by the pathological condition of the tendon and the apprehension shown during intervention.

Keywords:
Percutaneous needle electrolysis; Infrared thermography; Cutaneous blood flow
El Texto completo está disponible en PDF
Opciones de artículo
Herramientas
es en pt
Política de cookies Cookies policy Política de cookies
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.