Buscar en
Revista Clínica de Periodoncia, Implantología y Rehabilitación Oral
Toda la web
Inicio Revista Clínica de Periodoncia, Implantología y Rehabilitación Oral Resina fluida autoadhesiva utilizada como sellante de fosas y fisuras. Estudio d...
Información de la revista
Vol. 6. Núm. 1.
Páginas 5-8 (Abril 2013)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 6. Núm. 1.
Páginas 5-8 (Abril 2013)
Open Access
Resina fluida autoadhesiva utilizada como sellante de fosas y fisuras. Estudio de microinfiltración
Self-adhesive flowable composite-resin as a fissure sealant. A microleakage study
Visitas
2922
D. De Nordenflycht1,
Autor para correspondencia
diego.den@gmail.com

Correspondencia autor: Departamento de Odontología Restauradora, Universidad Andrés Bello. Viña del Mar, Chile. Los resultados preliminares de esta investigación fueron presentados en la Sesión General de la IADR en Foz de Iguazú, Brasil, 20-23 de Junio de 2012
, P. Villalobos2, O. Buchett3, A. Báez4
a Cirujano Dentista. Docente del Departamento de Odontología Restauradora, Universidad Andrés Bello. Viña del Mar, Chile
2 Magíster en Odontología Restauradora. Docente del Departamento de Odontología Restauradora, Universidad Andrés Bello. Viña del Mar, Chile
3 Cirujano Dentista. Chile
4 Magíster en Odontología Restauradora. Jefe del Departamento de Odontología Restauradora, Universidad Andrés Bello. Viña del Mar, Chile
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Objetivo

Evaluar la capacidad de sellado de una resina fluida autoadhesiva (Fusio Liquid Dentin, Pentron Clinical) utilizada como sellante de fosas y fisuras con distintos acondicionamientos de la superficie de esmalte.

Materiales y Métodos

Se seleccionaron 140 terceros molares recientemente extraídos, los que fueron distribuidos aleatoriamente en cuatro grupos (n=35) y recibieron una técnica de acondicionamiento del esmalte y aplicación de un sellante. Se establecieron los siguientes grupos: Grupo 1, grabado ácido y aplicación de sellante (Clinpro, 3M ESPE); Grupo 2, grabado ácido y aplicación de resina autoadhesiva (Fusio Liquid Dentin, Pentron Clinical); Grupo 3, aplicación de resina autoadhesiva; Grupo 4, microarenado del esmalte y aplicación de resina autoadhesiva. Los dientes sellados fueron termociclados (500 ciclos, 5-55°C), y posteriormente sumergidos en solución de nitrato de plata amoniacal por 24h (pH=14) y luego en revelador radiográfico (GBX, Kodak) por 8h. Posteriormente, los dientes fueron cortados para obtener 2 láminas por diente que fueron observadas bajo magnificación (4x) y analizadas digitalmente para evaluar la microinfiltración y la penetración en la fisura. Los resultados fueron analizados estadísticamente (ANOVA, Dunnett, p<0.05).

Resultados

La microinfiltración del Grupo 1 (13.18±9.25%) fue significativamente menor que la de los grupos 2, 3 y 4 (p<0.05). La penetración en la fisura en el Grupo 1 (98.92±2.77%) fue mayor que en los otros grupos, siendo esta diferencia significativa sólo con el Grupo 4.

Conclusión

Fusio Liquid Dentin tiene una capacidad de sellado inferior a la del sellante convencional Clinpro, independiente del acondicionamiento del esmalte que se utilice.

Palabras clave:
Fusio Liquid Dentin
microinfiltración
resina fluida autoadhesiva
sellantes
Abstract
Aim

To evaluate the sealing ability of a self-adhesive flowable composite-resin (Fusio Liquid Dentin, Pentron Clinical) with different conditioning treatments of the enamel surface used as a fissure sealant.

Materials and Method

140 recently extracted human third molars were selected and randomly divided into four groups (n=35). Each group received an enamel conditioning treatment and a sealant application. The following groups were established: Group 1, acid etching and sealant application (Clinpro, 3M ESPE); Group 2, acid etching and self-adhesive flowable composite-resin (Fusio Liquid Dentin, Pentron Clinical); Group 3, self-adhesive flowable composite-resin; Group 4, sandblasting and self-adhesive flowable compositeresin. Sealed teeth were thermocycled (500 cycles, 5-55°C) and immersed in ammoniacal silver nitrate solution for 24h (ph=14). After that, the teeth were immersed in radiographic developer solution (GBX, Kodak) for 8h. Then, the teeth were vertically sectioned to obtain two slides each that were observed under magnification (4x) and digitally analyzed to assess microleakage and sealant penetration. Results were statistically analyzed (ANOVA, Dunnett, p<0.05).

Results

Microleakage of Group 1 (13.18±9.25%) was significantly lower than groups 2, 3 and 4 (p<0.05). Group 1 had the highest sealant penetration mean (98.92±2.77%).

Conclusion

Fusio Liquid Dentin had a worse sealing ability than Clinpro irrespective of their enamel conditioning treatment when used as a fissure sealant. Among Fusio's groups, acid etching was the best enamel surface conditioning treatment.

Key words:
Fusio Liquid Dentin
microleakage
sealants
self-adhesive flowable resin
El Texto completo está disponible en PDF
Referencias Bibliográficas
[1.]
A. Ahovuo-Saloranta, A. Hiiri, A. Nordblad, M. Mäkelä, H.V. Worthington.
Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents.
Cochrane Database Syst Rev, 4 (2008),
[2.]
E.I. Cueto, M.G. Buonocore.
Sealing of pit and fissures with an adhesive resin: Its use in caries prevention.
J Am Dent Assoc, 75 (1967), pp. 121-128
[3.]
J. Kühnisch, U. Mansmann, R. Heinrich-Weltzien, R. Hickel.
Longevity of materials for pit and fissure sealing-results from a meta-analysis.
Dent Mater, 28 (2012), pp. 298-303
[4.]
J.L. Ferracane.
Resin composite-state of the art.
Dent Mater, 27 (2011), pp. 29-38
[5.]
I. Radovic, F. Monticelli, C. Goracci, Z.R. Vulicevic, M. Ferrari.
Self-adhesive resin cements: A literature review.
J Adhes Dent, 10 (2008), pp. 251-258
[6.]
R.O. Wadenya, C. Yego, M.B. Blatz, F. Mante.
Bond strength and microleakage of a new self-etch sealant.
Quintessence Int, 40 (2009), pp. 559-563
[7.]
T.M. Parco, D. Tantbirojn, A. Versluis, S. Beiraghi.
Microleakage of self-etching sealant on noncontaminated and saliva-contaminated enamel.
Pediatr Dent, 33 (2011), pp. 479-483
[8.]
Y. Guven, E.B. Tuna, O. Aktoren.
Shear bond strengths of self-etching and conventional fissure sealants.
J Dent Res, 86 (2007), pp. 226
[9.]
D. Harz, I. Urzúa, C. Córdova, M.C. Fresno.
Estudio in vitro de la microfiltración de un sellante de autograbado.
Rev Clin Periodoncia Implantol Rehabil Oral,, 2 (2009), pp. 148-151
[10.]
J. Perdigão, A. Sezinando, G. Gomes.
In vitro sealing potential of a self-adhesive pit and fissure sealant.
Quintessence Int,, 42 (2011), pp. e65-e73
[11.]
F. Conner, K. Vandewalle, J. Bartoloni.
Microleakage of a new self-etching sealant.
J Dent Res, 88 (2009), pp. 495
[12.]
M.A. Ghulman, M. Gomaa.
Effect of intra-orifice depth on sealing ability of four materials in the orifices of root-filled teeth: An ex-vivo study.
Int J Dent, 2012 (2012),
[13.]
C. Rengo, C. Goracci, J. Juloski, N. Chieffi, A. Giovannetti, A. Vichi, M. Ferrari.
Influence of phosphoric acid etching on microleakage of a self-etch adhesive and a self-adhering composite.
Aust Dent J, 57 (2012), pp. 220-226
[14.]
C. Goracci, M. Margvelashvili, A. Giovannetti, A. Vichi, M. Ferrari.
Shear bond strength of orthodontic brackets bonded with a new self-adhering flowable resin composite.
Clin Oral Investig, 17 (2013), pp. 609-617
[15.]
B. Van Meerbeek, K. Yoshihara, Y. Yoshida, A. Mine, J. De Munck, K.L. Van Landuyt.
State of the art of self-etch adhesives.
Dent Mater, 27 (2011), pp. 17-28
[16.]
J. Perdigão, P. Monteiro, G. Gomes.
In vitro enamel sealing ability of self-etch adhesives.
Quintessence Int,, 40 (2009), pp. 225-233
[17.]
S.A. Corona, M.C. Borsatto, L. Garcia, R.P. Ramos, R.G. Palma-Dibb.
Randomized, controlled trial comparing the retention of a flowable restorative system with a conventional resin sealant: One-year follow up.
Int J Paediatr Dent, 15 (2005), pp. 44-50
[18.]
M. Jafarzadeh, B. Malekafzali, N. Tadayon, S. Fallahi.
Retention of a flowable composite resin in comparison to a conventional resin-based sealant: One-year follow-up.
J Dent (Tehran), 7 (2010), pp. 1-5
Copyright © 2013. Sociedad de Periodoncia de Chile, Sociedad de Implantología Oral de Chile y Sociedad de Prótesis y Rehabilitación Oral de Chile
Opciones de artículo
Herramientas