Vol. 44. Núm. 3.
Páginas 103-111 (Enero 2002)
El interpolador de alto orden: un medio para incrementar la resolución de las imágenes pulmonares obtenidas mediante tomografía computarizada espiral*
The high-grade interpolator: a means for enhancing the resolution of helical computed tomography images of the lung
Visitas
3242
José María García-Santos
,1
Autor para correspondencia
jm-garsan@netscape.net

Correspondencia: JOSÉ MARÍA GARCÍA-SANTOS. Servicio de Radiodiagnóstico. HGU, «Morales Meseguer». C/ Marqués de los Vélez, s/n. 30008
, Silvia Torres del Río*, Ana Blanco*, Reme Rodríguez*, Manuel Canteras**, Elena Parlorio*, Antonio García*, Enrique Girela*, María Dolores Hernández*
* Servicio de Radiodiagnóstico, Hospital General Universitario «J. M.a Morales Meseguer». Murcia.
** Departamento de Bioestadística. Facultad de Medicina. Universidad de Murcia.
Este artículo ha recibido
Información del artículo
Objetivos

Nuestro trabajo pretende demostrar que la aplicación de un interpolador de alto orden en la reconstrucción de las imágenes to-rácicas aumenta la resolución, independientemente del filtro de alta re-solución.

Material y métodos

Ocho observadores separados en dos grupos (de expertos y de inexpertos) valoraron (en dos lecturas separadas en el tiempo) la misma sección torácica reconstruida cuatro veces (st-st, st-xs, b-st, b-xs), combinando los filtros (estándar-st y alta resolución-b) y los interpoladores (estándar-st y alto orden-xs). Clasificaron las imágenes de más a menos según la resolución percibida. Los resulta-dos se utilizaron para comparar tanto el grado de resolución introduci-do por el interpolador y el filtro, como la existencia o no de variabili-dad entre observadores y entre sus propias observaciones, influida o no por la experiencia.

Resultados

Seis de los ocho observadores clasificaron la imagen b-xs como la de mayor resolución en la mayoría de las ocasiones. En segundo lugar se clasificó la imagen b-st. En tercero la imagen st-xs. En último lugar la imagen st-st. Los otros dos observadores (uno entre los expertos y otro en los inexpertos) difirieron sólo en el orden de las imágenes st-xs y b-st, que fueron clasificadas en segundo y tercer lugar respectivamente. El grupo de expertos no mostró variabilidad intraob-servador aunque sí dos de los inexpertos.

Conclusiones

El interpolador de alto orden aumenta la resolución de las imágenes torácicas, independientemente de quien las evalúe, sin un aumento importante del ruido. Este hecho hace aconsejable su uso en las exploraciones torácicas con TC espiral (TCE).

Palabras Clave:
Tomografía computarizada espiral
Interpolación
Alta resolución
Tórax
Pulmón
Objective

The purpose of this study was to demonstrate that the use of a high-grade interpolator in the reconstruction of images of the chest increases the resolution, independently of the high-resolution filter.

Material and methods

Eight independent observers in two groups (experts and nonexperts) assessed (two readings separated by a time interval) the same section of the chest reconstructed four times (st-st, st-xs, b-st, b-xs), combining standard (st) and high-resolution (b) filters and standard (st) and high-grade (xs) interpolators. The images were classified from greater to lesser in terms of the resolution perceived. The results were used to compare the degree of resolution introduced by the interpolator and the filter and to determine whether or not there existed variability between observers and between the observations of each, and whether experience played a role in the findings.

Results

Six of the eight observers assigned the b-xs image the highest degree of resolution in the majority of cases, followed by the b-st image, the st-xs image and, finally, the st-st image). The other two observers (one expert and one nonexpert) differed only with respect to the order of the st-xs and b-st images, which they assigned the second and third places, respectively. The expert group showed no intraobser-ver variability, while two of the nonexpert observers did.

Conclusions

The high-grade interpolator enhances the resolution of images of the chest regardless of who evaluates them, while it does not substantially increase image noise. Thus, its use is recommended in helical computed tomography imaging of the lung.

Key words:
Helical computed tomography
interpolation
high resolution
chest
lung

Artículo

Opciones para acceder a los textos completos de la publicación Radiología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Radiología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos