Buscar en
Medicina Clínica (English Edition)
Toda la web
Inicio Medicina Clínica (English Edition) Cross-reactions between rheumatoid factor and IgM SARS-CoV-2
Journal Information
Vol. 155. Issue 9.
Pages 417-418 (November 2020)
Vol. 155. Issue 9.
Pages 417-418 (November 2020)
Letter to the Editor
Full text access
Cross-reactions between rheumatoid factor and IgM SARS-CoV-2
Reacciones cruzadas entre factor reumatoide e IgM SARS-CoV-2
Visits
4105
Marta Vinyé Bausàa, Rosa Bausà Perisb, Hèctor Corominasa,c,
Corresponding author
vancor@yahoo.com

Corresponding author.
a Universitat Autònoma de Barcelona (UAB), Barcelona, Spain
b Servei de Salut Laboral, Hospital Universitari de la Sant creu i Sant Pau, Barcelona, Spain
c Servei de Reumatologia, Hospital Universitari de la Sant creu i Sant Pau, Barcelona, Spain
This item has received
Article information
Full Text
Bibliography
Download PDF
Statistics
Full Text
To the Editor:

After the onset of the SARS-CoV-2 infection, special attention has been paid to the protection and transmission reduction in vulnerable populations. Of the methods described by Hernández-Pérez et al.1 and the rapid immunoglobulin tests,2 the most widely used methods are nucleic acid detection and tests based on the antigen-antibody reaction. We consider it important to focus attention on the possibility of IgM cross-reactivity between rheumatoid factors and IgM SARS-CoV-2 in patients with chronic inflammatory diseases and elevated rheumatoid factors, such as rheumatoid arthritis and Sjögren's syndrome.

The reverse transcription-polymerase chain reaction (RT-PCR) requires at least 4−6 h and it is very costly. It is the technique that is most used to diagnose active infection and it should be considered a technique of choice since: a) it detects the presence of the virus in nasopharynx samples in the acute phase; b) samples such as endotracheal aspirate, bronchial aspirate, and bronchoalveolar lavage can be used; c) it allows a large number of patients to be studied, due to the ease of automation of the procedures, and d) it is greater sensitivity (Se) and specificity (Sp) than the other methods available. It has fewer false positives (FP) and false negatives (FN). PCR-interpretation must be performed carefully and within the appropriate clinical context, especially when the result is negative.

Recent papers on COVID-19 have also focused on immunoassays (enzyme-linked immunosorbent assay [ELISA]) and on rapid antigen and antibody tests.2 The ELISA test is an immunoenzymatic assay that determines the presence of IgM and IgG antibodies, or a combination of IgM + IgA. Within the second group there are those that detect antigens or those that detect antibodies (IgM / IgG).

Regarding antigen-detection, there are not many studies that demonstrate the Se and Sp of nasopharyngeal swabs in SARS-CoV-2. However, it appears that the viral load is higher in the nasal passages than in the oropharynx, and that in the first days of infection the viral load ranges from 104 to 108 RNA copies per mL. This would suggest that the SARS-CoV-2 Ag detection could have good Se if a good antibody is available. The advantages of this test are the adequate Se and the speed, since immunochromatography tests usually produce results in about 15−30 min. The main disadvantage is the difficulty in processing a large number of samples in a short period of time.

The detection of specific IgM and IgG antibodies allows the immune response to the virus to be qualitatively and quantitatively characterised. Once infected by SARS-CoV-2, IgM is detected from 3−5 days from the onset of symptoms and disappears around day 21 post-infection. IgG appears later, and is normally detected after 14 days, increasing during the convalescence period. IgG remain in the blood beyond the convalescence period, providing the hoped-for long-term immunity which is yet to be confirmed.3,4

Recently, the techniques gold immunochromatography assay (GICA) and ELISA were used to study the possible interaction in the detection test for SARS-CoV-2 IgM antibodies. A total of 86 serum samples from different patients were used: 5 influenza A virus (flu A) IgM-positive sera, 5 influenza B virus (flu B) IgM-positive sera, 5 Mycoplasma pneumoniae IgM-positive sera, 5 Legionella pneumophila IgM-positive sera, 6 sera of HIV infection patients, 36 for rheumatoid factor IgM (RF-IgM)-positive sera, 5 sera from hypertensive patients, 5 sera from diabetes mellitus patients, and 14 sera with SARS-CoV-2 infection.5 The factors causing FP IgM antibodies were analysed. In addition, the urea dissociation test was used to dissociate the SARS-CoV-2 IgM-positive serum of using the best dissociation concentration. Positive SARS-CoV-2 IgM was detected in 22 middle-high level RF-IgM-positive sera and, as expected, in all 14 samples from COVID-19 patients. The other 50 sera were negative. When using GICA and ELISA to detect SARS-CoV-2 IgM, the level of RF-IgM in the serum is indirectly quantified and the urea dissociation test should be performed to avoid the risk of FP results. When the urea dissociation concentration was 6 mol/L, SARS-CoV-2 IgM was positive in one middle-high level RF-IgM-positive serum and in all 14 sera from COVID-19 patients. When the urea dissociation concentration was 4 mol/L and the avidity index (AI) lower than 0.371 was set to negative, the test results were positive for SARS-CoV-2 in 3 middle-high level RF-IgM-positive sera, as well as in the 14 COVID-19 sera. The authors concluded that, to detect SARS-CoV-2 IgM, the level of RF-IgM in the serum should be assessed and the urea dissociation test should be performed to avoid the risk of FP results.

However, the urea dissociation test cannot completely eliminate RF-IgM interference. Therefore, when SARS-CoV-2 IgM results are still positive after urea dissociation, PCR should be used for viral nucleic acid diagnosis. These data suggest that the methods described should be used to eliminate or reduce the impact of cross-reaction when using GICA and ELISA methods for the detection of SARS-CoV-2 IgM. This fact would mean an improvement in the screening of suspected cases and high-risk groups, as well as in the evaluation, prevention and control of SARS-CoV-2.

The rapid evolution of the pandemic has required an agile and accelerated response. Knowledge about SARS-CoV-2 is increasing, but there is still a need to study the discrepancies in the methods of diagnosing the disease. It is important to intensify studies of each of the tests and the causes of the possible FP results, and especially in RF-positive diseases such as rheumatoid arthritis and Sjögren's syndrome.

References
[1]
J.M. Hernandez-Perez, E. Martin-Gonzalez, M. Pino-Yanes.
Virtudes y dificultades en los test diagnósticos de la infección por el SARS-CoV-2.
[2]
J. Constan Rodriguez, C. Fernandez Roldán, C. López Robles.
El test rápido de inmunoglobulinas confirma un caso sospechoso de COVID-19.
[3]
Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica: Documento de posicionamiento de la SEIMC sobre el diagnóstico microbiólogico de COVID-19. https://seimc.org/contenidos/documentoscientificos/recomendaciones/seimc-rc-2020.
[4]
López J., Mitjà O. Salida coordinada del confinamiento. Propuesta de intervenciones de salud pública para el control de la infección SARS-CoV-2 en la comunidad. https://www.diariandorra.ad/uploads/documentos/2020/04/03/_document_5f7df7f4.pdf.
[5]
Q. Wang, Q. Du, B. Guo, et al.
A method to prevent SARS-CoV-2 IgM false positives in gold immunochromatography and enzyme-linked immunosorbent assays.
J Clin Microbiol., (2020),

Please cite this article as: Vinyé Bausà M, Bausà Peris R, Corominas H. Reacciones cruzadas entre factor reumatoide e IgM SARS-CoV-2. Med Clin (Barc). 2020;155:417–418.

Copyright © 2020. Elsevier España, S.L.U.. All rights reserved
Article options
Tools
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.medcle.2020.08.014
No mostrar más