metricas

Enfermería Intensiva

Sugerencias
Enfermería Intensiva Vascular complications of intravenous vancomycin: Safety of peripheral, midline ...
Información de la revista
Vol. 37. Núm. 4.
(Octubre - Diciembre 2026)
Cita
Cita
Compartir
Descargar PDF
Más opciones de artículo
Visitas
295
Vol. 37. Núm. 4.
(Octubre - Diciembre 2026)
Review article
Acceso a texto completo

Vascular complications of intravenous vancomycin: Safety of peripheral, midline and central catheters. A scoping review

Complicaciones vasculares de la vancomicina intravenosa: seguridad de los catéteres periféricos, de línea media y centrales. Revision exploratoria
Visitas
295
Irrintzi Fernández-Aedoa,b, Sendoa Ballesteros-Peñaa,b,c, Gorka Vallejo-De La Hoza,b,d, Julia Fernandez-Alonsoa,e,
Autor para correspondencia
Julia.fernandez@ehu.eus

Corresponding author.
a Biobizkaia Health Research Institute, Spain
b Nursing I Department, Faculty of Medicine and Nursing, University of the Basque Country (UPV EHU), Spain
c Osakidetza, Santa Marina Hospital, Spain
d Osakidetza, Galdakao-Usansolo Hospital, Spain
e Physiology Department, Faculty of Medicine and Nursing, University of the Basque Country (UPV EHU), Spain
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
fig0005
fig0010
fig0015
Tablas (3)
Table 1. Search strategies used.
Tablas
Table 2. Summary of included studies, vancomycin administration characteristics and main vascular outcomes.
Tablas
Table 3. Definitions and diagnostic methods used for vascular complications in the included studies.
Tablas
Material adicional (2)
Abstract
Introduction

Vancomycin treats severe infections by resistant bacteria, but its acidity and local toxicity demand careful intravenous administration. Central venous catheters reduce these risks but pose complications. Midline catheters offer a less invasive alternative, though evidence remains limited.

Objectives

To map and describe the available clinical evidence on the safety and vascular complications associated with peripheral intravenous administration of vancomycin, compared with other vascular access devices, focusing on the type of complications reported, their diagnostic methods, and the methodological characteristics of the studies.

Method

A scoping review was conducted following the PRISMA-ScR guidelines. A comprehensive literature search was performed in Medline (via PubMed), Web of Science, Cochrane Library, CINAHL, and CUIDEN databases to identify studies reporting on intravenous vancomycin administration, catheter type and associated complications.

Results

Four studies met the inclusion criteria—two clinical trials and two cohort studies—with sample sizes ranging from 14 to 1087 participants. All studies reported complications attributed to vancomycin, regardless of catheter type. Two studies reported low rates of certain complications in patients receiving vancomycin through midline catheters, while other studies described complications associated with peripheral administration or recommended central access based on clinical considerations.

Conclusion

The available studies report heterogeneous findings regarding vascular complications associated with different vascular access devices for vancomycin administration. The evidence is limited and methodologically diverse, highlighting important gaps in the literature regarding outcome definitions, diagnostic approaches, and comparative evaluation across catheter types.

Keywords:
Vancomycin
Midline catheter
Peripheral intravenous catheter
Central venous catheter
Phlebitis
Thrombosis
Scoping review
Resumen
Introducción

La vancomicina es utilizada para tratar infecciones graves por bacterias resistentes, pero su acidez y toxicidad local exigen una administración intravenosa controlada. Los catéteres venosos centrales reducen estos riesgos, aunque pueden generar complicaciones. Los catéteres de línea media representan una alternativa menos invasiva, aunque la evidencia sigue siendo limitada.

Objetivos

Mapear y describir la evidencia clínica disponible sobre la seguridad y las complicaciones vasculares asociadas con la administración intravenosa periférica de vancomicina, en comparación con otros dispositivos de acceso vascular, centrándose en el tipo de complicaciones notificadas, sus métodos de diagnóstico y las características metodológicas de los estudios.

Método

Se realizó una revisión exploratoria siguiendo las directrices PRISMA-ScR. Se llevó a cabo una búsqueda bibliográfica exhaustiva en las bases de datos Medline (a través de PubMed), Web of Science, Cochrane Library, CINAHL y CUIDEN para identificar estudios que informaran sobre la administración intravenosa de vancomicina, el tipo de catéter y las complicaciones asociadas.

Resultados

Cuatro estudios cumplieron los criterios de inclusión (dos ensayos clínicos y dos estudios de cohortes), con tamaños muestrales entre 14 y 1.087 participantes. Todos informaron de complicaciones atribuidas a la vancomicina, independientemente del tipo de catéter. Dos estudios señalaron bajas tasas de determinadas complicaciones en pacientes con vancomicina administrada a través de catéteres de línea media, mientras que otros estudios describieron complicaciones asociadas a la administración periférica o recomendaron el acceso central.

Conclusión

Los estudios disponibles presentan resultados heterogéneos en cuanto a las complicaciones vasculares asociadas a los distintos dispositivos de acceso vascular utilizados para la administración de vancomicina. La evidencia es limitada y metodológicamente diversa, lo que pone de manifiesto importantes lagunas en la literatura en lo que respecta a las definiciones de los resultados, los enfoques diagnósticos y la descripción de la evidencia disponible.

Palabras clave:
Vancomicina
Catéter de línea media
Catéter intravenoso periférico
Catéter venoso central
Flebitis
Trombosis
Revisión Exploratoria
Resumen gráfico
Texto completo
Introduction

Vancomycin (pH 3.9) is a glycopeptide antibiotic widely used in the treatment of serious infections caused by gram-positive bacteria, particularly methicillin-resistant Staphylococcus aureus and coagulase-negative Staphylococcus species.1 This medication has two characteristics that affect its route of administration: its pH and its direct toxicity to the vascular endothelium,2,3 which is why it has been associated with a higher risk of phlebitis. Chemical phlebitis occurs due to vein irritation from solutions with a pH different from that of blood plasma.4 Therefore, due to its pharmacokinetic profile and potential for local toxicity, intravenous administration of vancomycin requires a safe and effective vascular access route.

Traditionally, Central Venous Catheters (CVCs) have been considered the standard for prolonged vancomycin infusion, as the drug is immediately diluted, thereby alleviating its local aggressiveness.1,5 However, their use is associated with significant complications such as catheter-associated bloodstream infections, thrombosis, and higher costs.5

In recent years, the available evidence suggests that Midline Catheters (MLCs) may be a feasible alternative in selected contexts; however, conclusions are limited by the small number and heterogeneity of studies.7 MLCs are typically inserted into the deeper veins of the arm without reaching central circulation (as Peripherally Inserted Central Catheters (PICCs) do) but ensure that the catheter delivers the medication into a vein with intermediate flow. They are mainly indicated for patients expected to require prolonged intravenous therapy.6,7

Given the location of both types of catheters for the administration of medications considered irritating, the use of a CVC is generally indicated. The use of an MLC is a strategy that avoids central venous cannulation and, consequently, its complications.5 Indeed, literature regarding catheter use highlights that MLCs help avoid the use of CVCs or promote their early removal.8,9 Limiting CVC insertion reduces the incidence of catheter-related complications, both mechanical (arterial puncture, pneumothorax) and infectious (bacterial), due to lower bacterial colonization of the upper limb compared to other body areas where CVCs are placed.10 Nevertheless, there is an ongoing clinical debate regarding the safety, efficacy, and risk of complications associated with the use of MLCs compared to CVCs for antimicrobial therapy.10,11

Despite the widespread use of vancomycin and the growing interest in peripheral and midline vascular access devices, the available evidence addressing vascular complications according to catheter type remains heterogeneous, methodologically limited, and inconsistently reported. In particular, studies differ substantially in the complications assessed, their diagnostic criteria, and the extent to which catheter-related outcomes are systematically evaluated.

This fragmented and inconsistently reported evidence base underscores the need for a structured mapping of the literature. Accordingly, a scoping review approach was considered methodologically appropriate. Therefore, the objective of this review is to map the existing evidence on peripheral intravenous vancomycin administration, identify which vascular complications have been evaluated and how they were measured, and highlight relevant methodological limitations and knowledge gaps to inform future research and clinical practice.

Review methodsDesign

This study was conducted as a scoping review in accordance with the PRISMA Extension for Scoping Reviews (PRISMA-ScR)12 guidelines. The completed PRISMA-ScR checklist is provided as Supplementary Material I. This methodological approach, structured according to the Population–Concept–Context (PCC) framework recommended for scoping reviews,13 was selected to allow a comprehensive mapping of the available literature on vascular access devices used for intravenous vancomycin administration, including the types of vascular complications reported, the diagnostic methods employed, and the methodological characteristics of the included studies.

Protocol and registration

A detailed protocol for this scoping review was developed a priori, specifying the objectives, eligibility criteria, search strategy, and data charting procedures, in accordance with PRISMA-ScR guidance.14 Eligibility criteria were established before the literature search was conducted and were used to guide both the search strategy and the study selection process.

The protocol was not prospectively registered in an external repository (such as PROSPERO or the Open Science Framework), as current guidance does not mandate prospective registration for scoping reviews and PROSPERO does not routinely accept them. Instead, the protocol was retained within the research team and is available from the corresponding author on reasonable request, thereby supporting methodological transparency and reproducibility.

Eligibility criteria

The intervention of interest was intravenous administration of vancomycin via peripheral venous access, including midline catheters, short peripheral catheters, and mini midlines. Both continuous and intermittent infusion modalities were considered.

Selected studies had to report at least one of the following outcomes: phlebitis, venous thrombosis (superficial or deep), infiltration or extravasation, catheter-related infections (e.g., catheter-associated bloodstream infections), costs associated with access or complication management, nursing time, or clinical efficiency. Excluded were experimental studies in animals or in vitro investigations, literature reviews, editorials, letters to the editor, or commentaries without original data; studies in which vancomycin was not administered intravenously; or studies where it was not possible to identify the type of venous access used. The studies were limited to publications from 01 January 2000 to 31 May 2025, indexed in the following databases: Medline (via PubMed), Web of Science, Cochrane Library, CINAHL and CUIDEN.

Search strategy

A systematic and comprehensive literature search was performed in Medline (via PubMed), Web of Science, Cochrane Library, CINAHL, and CUIDEN from 01 January 2000 to 31 May 2025. The search strategy combined controlled vocabulary terms and free-text keywords related to vancomycin, vascular access devices, and vascular or device-related complications. The complete search strategies adapted to each database are presented in Table 1.

Table 1.

Search strategies used.

Database  Search strategy 
Medline (via PubMed)  (“Vancomycin”[MeSH] OR vancomycin OR “glycopeptide antibiotic*” OR “glycopeptide*”) AND (“Midline Catheter”[MeSH] OR “Midline Catheter*” OR “midline” OR “Peripheral Intravenous Catheter”[MeSH] OR “peripheral intravenous catheter*” OR “short peripheral catheter*” OR “long peripheral catheter*” OR “peripheral venous catheter*” OR “PVC” OR “SPC” OR “Peripherally Inserted Central Catheter”[MeSH] OR “peripherally inserted central catheter*” OR PICC OR “Central Venous Catheter”[MeSH] OR “central venous catheter*” OR CVC OR “vascular access device*” OR “VAD” OR “intravascular catheter*”) AND (“Phlebitis”[MeSH] OR phlebitis OR “Thrombophlebitis”[MeSH] OR thrombophlebitis OR “Venous Thrombosis”[MeSH] OR thrombosis OR “vein thrombosis” OR infiltration OR extravasation OR “extravasation of diagnostic and therapeutic materials”[MeSH] OR “catheter-related complication*” OR “device-related complication*” OR “catheter failure” OR “catheter malfunction” OR “vascular complication*” OR “line complication*” OR “infusion-related complication*” OR “local complication*”) 
Web of Science  (vancomycin OR “glycopeptide antibiotic*” OR “glycopeptide*”) AND (“midline catheter*” OR midline OR “peripheral intravenous catheter*” OR “peripheral venous catheter*” OR “short peripheral catheter*” OR “long peripheral catheter*” OR “PVC” OR “SPC” OR “peripherally inserted central catheter*” OR PICC OR “central venous catheter*” OR CVC OR “vascular access device*” OR “intravascular catheter*”) AND (phlebitis OR thrombophlebitis OR thrombosis OR “vein thrombosis” OR infiltration OR extravasation OR “catheter complication*” OR “vascular complication*” OR “device-related complication*” OR “catheter failure” OR “catheter malfunction” OR “infusion-related complication*” OR “local complication*”) 
Cochrane Library  (vancomycin OR “glycopeptide antibiotic*” OR “glycopeptide*”) AND (“midline catheter*” OR midline OR “peripheral intravenous catheter*” OR “peripheral venous catheter*” OR “short peripheral catheter*” OR “long peripheral catheter*” OR “PVC” OR “SPC” OR “peripherally inserted central catheter*” OR PICC OR “central venous catheter*” OR CVC OR “vascular access device*” OR “intravascular catheter*”) AND (phlebitis OR thrombophlebitis OR thrombosis OR infiltration OR extravasation OR “catheter failure” OR “catheter complication*” OR “device-related complication*” OR “vascular complication*” OR “line complication*” OR “infusion-related complication*”) 
CUIDEN  (vancomicina) AND (catéter OR “catéter venoso” OR “catéter intravenoso periférico” OR “catéter periférico corto” OR “catéter periférico largo” OR “línea media” OR “catéter de línea media” OR “catéter venoso central” OR PICC OR CVC OR “dispositivo de acceso vascular” OR “acceso vascular”) AND (flebitis OR tromboflebitis OR trombosis OR “trombosis venosa” OR infiltración OR extravasación OR “complicación del catéter” OR “complicación vascular” OR “fallo del catéter” OR “malfunción del catéter” OR “complicación local”) 
CINAHL ultimate  (MH “Vancomycin” OR vancomycin OR “glycopeptide antibiotic*” OR “glycopeptide*”) AND (MH “Midline Catheter” OR “midline catheter*” OR midline OR MH “Peripheral Intravenous Catheters” OR “peripheral intravenous catheter*” OR “short peripheral catheter*” OR “long peripheral catheter*” OR “peripheral venous catheter*” OR “PVC” OR “SPC” OR MH “Peripherally Inserted Central Catheter” OR PICC OR MH “Central Venous Catheters” OR CVC OR “vascular access device*” OR “intravascular catheter*”) AND (MH “Phlebitis” OR phlebitis OR thrombophlebitis OR thrombosis OR infiltration OR extravasation OR “catheter failure” OR “catheter complication*” OR “device-related complication*” OR “vascular complication*” OR “infusion-related complication*” OR “local complication*”) 

CVC: Central Venous Catheter, PICC: Peripherally Inserted Central Catheter.

As a secondary strategy, the reference lists of the retrieved articles were reviewed to identify potentially relevant studies not found in the electronic databases. Included studies comprised randomized clinical trials, observational studies (cohort, case-control, and cross-sectional), and prospective or retrospective studies with clinical data regarding complications or safety in adult patients (>18 years).

Selection of sources of evidence

Title and abstract screening were conducted independently and in duplicate by two reviewers. Subsequently, full-text eligibility assessment was also performed independently. Discrepancies were resolved through discussion and, when necessary, consultation with a third reviewer. A formal statistical measure of inter-reviewer agreement was not calculated, as the screening process relied on consensus resolution.

Data charting process

For data extraction from each article, a template was used based on the PCC framework recommended for scoping reviews.13 Extraction was performed by one reviewer and checked by a second, with disagreements resolved by discussion and, where required, by involving a third reviewer. The charted data included study design, sample characteristics, catheter type, vancomycin administration protocol, reported vascular complications, diagnostic methods, and key methodological features.

The primary outcomes of interest were vascular complications potentially related to intravenous vancomycin administration via peripheral or midline catheters, namely: phlebitis, venous thrombosis (superficial or deep), infiltration or extravasation, catheter-related infection (including catheter-associated bloodstream infection), and non-infectious device failure (e.g. leakage, dislodgement or malfunction). These outcomes were operationalized according to the definitions provided in each primary study, including the use of clinical criteria, validated phlebitis or infiltration scales, and imaging-based diagnosis (e.g. compression ultrasonography) where available.

In addition, we extracted data on broader clinical and organizational outcomes when reported, such as treatment interruptions, catheter replacement or recannulation, unplanned escalation to central venous access, nursing workload, and costs associated with catheter insertion or complication management.

Data charting followed a pre-specified template aligned with the PPC framework. For each included study, two reviewers independently extracted: (1) study characteristics (country, year, design, setting, sample size and population); (2) catheter and intervention characteristics (type of catheter, lumen and length when reported, vancomycin concentration, infusion modality and duration, flushing regimen); (3) predefined vascular outcomes, their operational definitions and diagnostic methods (clinical assessment, ultrasound or other imaging, assessment frequency, and use of validated scales); (4) quantitative results for each outcome (number of events and denominators where available); and (5) results of the risk of bias assessment.

A standardized data charting form was piloted on one study and refined before being applied to the remaining records, to ensure completeness and consistency in data collection.

Risk of bias assessment

The methodological quality of the included studies was assessed using validated tools adapted to the study design. In the context of this scoping review, the purpose of this assessment was to provide contextual information regarding the methodological rigor and potential sources of bias in the included studies, rather than to support causal inference or comparative effectiveness interpretations.

For randomized clinical trials, the RoB 2 (Risk of Bias 2) tool proposed by Cochrane was used.15 For observational studies (cohorts and retrospective studies), the ROBINS-I (Risk Of Bias In Non-randomized Studies – of Interventions) tool was applied.16 Risk of bias assessment was performed independently by two reviewers using the appropriate tools according to study design. Any disagreements were resolved through discussion and, when necessary, consultation with a third reviewer. The results were summarized in tables and graphical representations to facilitate transparent interpretation.

Importantly, the risk of bias assessment was not used to exclude studies or rank the strength of the evidence. Instead, it was incorporated to facilitate a more cautious interpretation of the heterogeneity, methodological limitations, and uncertainty of the available literature.

Synthesis of results

Due to substantial clinical and methodological heterogeneity across studies—including differences in design, catheter types, vancomycin concentrations, outcome definitions, diagnostic methods (clinical versus systematic ultrasound), and the absence of comparable effect measures—quantitative synthesis was neither methodologically appropriate nor aligned with the scoping review objective. Moreover, the high or critical risk of bias identified in several studies further limited the comparability of findings across studies.

ResultsStudy selection

Despite the use of a comprehensive and intentionally broad search strategy, a substantial proportion of records were excluded during full-text review. The most frequent reasons for exclusion were the absence of a clear differentiation between vascular access device types, the lack of complication data disaggregated by catheter type, or the reporting of adverse events without explicit attribution to intravenous vancomycin administration.

In addition, many studies evaluated vancomycin safety as part of broader antimicrobial protocols or vascular access programs without providing device-specific or drug-specific vascular outcomes, which limited their eligibility for inclusion. These exclusions highlight an important gap in the current literature, namely the scarcity of studies that systematically assess vascular complications of vancomycin according to the type of venous access device used.

Consistent with the objectives of a scoping review, the results are presented descriptively, focusing on study characteristics, types of vascular access devices evaluated, reported complications, and methods used for outcome assessment.

The search across five electronic biomedical databases identified a total of 136 records: 44 records from Medline (via PubMed), 78 from Web of Science, 1 from Cochrane library, 1 from CUIDEN and 12 from CINAHL, which were reduced to 74 after duplicates were removed. Of these, 43 were excluded based on title and abstract screening. The remaining articles underwent full-text assessment, leading to the exclusion of 27 studies for the following reasons: inclusion of pediatric populations (n=10), non-human studies (n=4), and opinion papers, reviews, or conference abstracts (n=13) (Fig. 1). A comprehensive list of the studies excluded after full-text evaluation, along with the reasons for their exclusion, is provided in Supplementary Material II.

Figure 1.

Flow chart of the results of the bibliographic search.

Study characteristics

Finally, the study was conducted based on four references,19–22 published between 2010 and 2024 and originating from two different countries: the United States and Italy. Two studies employed a prospective clinical trial design, whereas the remaining two were observational cohort studies, one retrospective and one prospective.

Sample sizes varied substantially across studies, ranging from 14 to 1086 participants. All studies included adult patients receiving intravenous vancomycin therapy in hospital settings. The duration of treatment differed between studies, ranging from short courses of more than 24h to prolonged administration lasting up to 25 days. Where reported, patients were predominantly male, accounting for approximately 51% of the total study population.

The studies evaluated different types of vascular access devices for vancomycin administration, including peripheral intravenous catheters, MLCs and PICCs. In most studies, catheter insertion and maintenance were performed by nursing staff as part of routine clinical care.

Additional methodological and intervention characteristics, including catheter type, vancomycin administration protocols, and reported vascular outcomes, are summarized in Table 2.

Table 2.

Summary of included studies, vancomycin administration characteristics and main vascular outcomes.

Author, country & year  Study design  Sample & catheter  Vancomycin administration protocol  Phlebitis (n/N)  Thrombosis (n/N)  Infiltration (n/N)  Infection (n/N)  Assessment method 
Roszell & Jones.United States, 2010.17  Retrospective observational study  n=49 peripheral intravenous catheters (length not reported)  Infusion protocol not reported; concentration not reported; saline flush included in start kit.  Not quantified (assessed using INS scale)  Not assessed  Higher infiltration scores reported  0/49  Nurse bedside clinical assessment recorded on data sheet and verified with medical records. 
Caparas & Hu.United States, 2014.18  Prospective clinical trial  n=54 patients: 29 midline (30 catheters), 25 PICC (28 catheters)a (length not reported)  Concentration 4mg/mL; infusion pump over ≥60min (once or twice daily); line patency confirmed by blood aspiration and saline flush.  Midline: 0/30 PICC: 0/28  Midline: 0/30 PICC: 0/28  Midline: 3/30 (Grade I)bPICC: 0/28  Midline: 0/30 confirmed, PICC: 0/28 confirmed, 1/28 suspected  Daily observation; line patency check via aspiration and saline flush; ultrasound assessment for line position. 
Caparas & Hung.United States, 2017.19  Retrospective observational study  n=1086MLC (length not reported)  Dilution 4mg/mL; infusion pump ≥60min (1g dose); flushing with 10mL normal saline every 8–12h.  6/1086  0/1086  13/1086  0/1086  Chart review, phlebitis scale, clinical assessment. 
Scarano et al.Italy, 2024.20  Prospective clinical trial  n=14MLC; 3Fr (20G) polyurethane long peripheral cannula, 8cm in length.  Continuous infusion (1g/day); dilution 20mg/mL (1g/50mL) vs 4mg/mL (1g/250mL); flushing not reported.  14/14  14/14  Not reported  Not reported  Daily ultrasound, Visual Exit-Site Score 

INS: Infusion Nurses Society; CVC: Central Venous Catheter; PICC: Peripherally Inserted Central Catheter; MLC: Midline Catheter.

When specific administration details (concentration, infusion mode and duration, catheter length, flushing regimen) were not provided in the primary sources, this is indicated as ‘not reported’.

a

The number of catheters may be higher than the number of patients, as some patients required more than one device during the course of the study.

b

According to the Infusion Nurses Society (INS) criteria for classifying infiltrations on a scale of 0–4, with Grade I defined as mild swelling of less than 1in. (2.54cm).21

Catheter and vancomycin administration characteristics

The included studies evaluated several types of vascular access devices for intravenous vancomycin administration. These comprised short peripheral intravenous catheters, MLCs, and PICCs. The characteristics of catheter devices, including length and gauge, were inconsistently reported across studies.

Vancomycin administration protocols also varied between studies. Reported concentrations ranged from 4mg/mL to 20mg/mL. Both intermittent infusion and continuous infusion strategies were described. Intermittent administration was generally delivered via infusion pump over a minimum duration of 60min, whereas continuous infusion protocols involved prolonged administration over 24h.

Maintenance practices differed between studies. Some studies reported routine flushing with normal saline to maintain catheter patency,17–19 while others did not provide detailed information regarding flushing regimens or catheter care procedures.20

Further details regarding catheter characteristics, vancomycin dilution, infusion modality, and maintenance practices are presented in Table 2.

Outcome definitions and diagnostic methods

Substantial variability was identified in the definitions and diagnostic approaches used to assess vascular complications across the included studies. The complications evaluated included phlebitis, venous thrombosis, infiltration, extravasation, and catheter-related infection.

Outcome definitions were not standardized across studies. In some cases, complications were defined using clinical criteria documented in patient records,17,19 whereas other studies applied specific diagnostic scales or imaging techniques.18,20

Diagnostic approaches differed markedly. Several studies relied primarily on bedside clinical assessment performed by nursing staff, sometimes supported by chart review.17–19 In contrast, one study incorporated systematic imaging through daily compression ultrasonography to detect venous thrombosis.20

The frequency of outcome assessment also varied. Some studies conducted daily monitoring of catheter sites during vancomycin therapy,17,20 whereas others relied on retrospective chart review covering the entire catheter dwell period.17,19

Validated assessment tools were used inconsistently. While certain studies reported the use of Infusion Nurses Society (INS)-based scales or other standardized scoring systems,17–19 others did not specify the use of validated instruments.20 The definitions of vascular outcomes, diagnostic methods, and monitoring strategies used in each study are summarized in Table 3.

Table 3.

Definitions and diagnostic methods used for vascular complications in the included studies.

Study  Clinical outcome assessed  Outcome definition  Diagnostic method  Assessment frequency  Validated scale  Type of thrombosis reported 
Roszell & Jones, 2010.17  Phlebitis and infiltration; workload; treatment delays.  Phlebitis/infiltration scores, repeat venepunctures, nurse time and dose delay.  Nurse bedside assessment documented on data sheet and confirmed with medical records.  After each antibiotic dose during peripheral intravenous therapy on the unit.  INS-based phlebitis and infiltration scales.  Thrombosis not assessed or reported. 
Caparas & Hu, 2014.18  Thrombosis, phlebitis, infiltration, infection, dislodgement, leak; insertion cost.  Device-related complications during vancomycin administration via midline.  Daily clinical assessment; ultrasound to confirm catheter position.  At least once daily during infusion.  INS Infiltration Scale.  Catheter-related thrombosis assessed; none detected. 
Caparas & Hung, 2017.19  Thrombosis, phlebitis, infiltration, infection, extravasation; cost of catheter insertion.  Device-related complications during vancomycin administration via midline.  Retrospective chart review.  During catheter dwell time.  INS-based phlebitis scale. (No validated scale systematically applied).  Phlebitis and infiltration reported; no deep vein thrombosis, extravasation or catheter-related bloodstream infection. 
Scarano et al., 2024.20  Thrombosis, thrombophlebitis.  Venous thrombosis at the distal tip of the peripheral cannula during continuous vancomycin infusion.  Daily ultrasound (compression ultrasonography) and clinical assessment.  Every 24h during infusion.  Visual Exit-Site Score.  Thrombosis detected in 100% of patients (asymptomatic); earlier onset with higher concentration. 

INS: Infusion Nurses Society.

Quantitative results for vascular complications

The quantitative findings for vascular complications varied across studies and catheter types. Due to differences in outcome definitions, diagnostic methods, and study designs, the reported incidence of complications showed considerable variability.

Phlebitis was reported in two studies. In one observational cohort study involving 1086 patients receiving vancomycin through midline catheters, six cases of phlebitis were documented.19 In another study using systematic imaging and clinical assessment, phlebitis or thrombophlebitic changes were identified in all participants.20

Venous thrombosis was assessed in three studies. Two studies reported no cases of clinically evident thrombosis in patients receiving vancomycin through midline or PICC devices.18,19 In contrast, one prospective study employing daily ultrasound examination detected venous thrombosis at the catheter tip in all participants, although these events were described as asymptomatic.20

Infiltration events were reported in two studies. One study described higher infiltration scores associated with peripheral intravenous catheter use,17 while another reported three infiltration events among midline catheters.18

Catheter-related infection was rarely reported. No confirmed catheter-related bloodstream infections were documented across the included studies, although one suspected infection was reported in a PICC device.18

Overall, the small number of studies and the heterogeneity in diagnostic approaches and outcome definitions limit direct comparison of complication rates across catheter types. The quantitative results for each vascular outcome are presented in Table 2. When administration characteristics were not described in the primary studies, this is explicitly indicated as ‘not reported’.

Risk of bias and methodological limitations

The methodological quality of the included studies was assessed using the RoB 2 tool15 for randomized trials and the ROBINS-I tool16 for observational studies.

Among the two studies with an experimental design, one was assessed as having a low risk of bias,22 whereas the other presented a high risk of bias.18 The prospective trial by Scarano et al. included standardized intervention procedures, systematic daily ultrasound evaluation, and complete follow-up, although details regarding the randomization process were not fully reported.20 In contrast, the study by Caparas and Hu used a non-random allocation method based on medical record numbers, did not implement blinding, and allowed protocol deviations without intention-to-treat analysis.18

The two observational studies also presented methodological limitations. According to the ROBINS-I assessment, the study by Roszell and Jones was classified as having a critical risk of bias, primarily due to the absence of control for confounding variables, non-standardized outcome assessment, and missing data in relevant variables.17 The study by Caparas and Hung was assessed as having a serious risk of bias, mainly related to the absence of a comparison group and the reliance on retrospective chart review.19

The detailed results of the risk of bias assessment are presented in Fig. 2.

Figure 2.

Risk of bias for each criterion presented as percentages of all included studies. (A) Cochrane RoB 2.0(Risk of Bias 2 (RoB 2) tool | Cochrane Methods, s. f.); (B) ROBINS-I V1(ROBINS-I tool | Cochrane Methods, s. f.). +: Low risk of bias, o: moderate risk of bias, −: high risk of bias, blank: unclear risk of bias.

Discussion

This scoping review was designed to map and characterize the available evidence rather than to determine comparative effectiveness between vascular access devices. Vancomycin has been regarded as one of the primary antibiotics for treating infections caused by gram-positive bacteria.1 However, due to its physicochemical properties (such as low pH) its infusion can cause adverse effects like phlebitis in hospitalized patients.4 Importantly, this scoping review does not aim to determine the superiority of one vascular access device over another. Rather, it seeks to examine how safety outcomes have been defined, measured, and interpreted across studies.

As recommended for scoping reviews, the objective of this study was not to synthesize effect estimates or establish comparative effectiveness between vascular access devices, but to map the characteristics of the available evidence and identify methodological gaps in the literature. The limited number of eligible publications and the heterogeneity in diagnostic criteria and reporting standards suggest that the current body of evidence is fragmented and methodologically inconsistent.

Taken together, the available evidence remains limited and methodologically heterogeneous. Marked variability in reported complication rates was observed across studies, with some authors reporting a 100% rate of thrombophlebitis with peripheral20 while others reported no cases.18,19 This variability should be interpreted not only in light of differences in diagnostic methods and outcome definitions, but also considering the substantial methodological limitations identified through the RoB 2 and ROBINS-I assessments. For example, while Scarano et al., employed systematic daily ultrasound evaluation to detect thrombosis,20 other studies relied primarily on clinical assessment or retrospective chart review.18,19 In particular, the absence of standardized outcome assessment, inconsistent use of imaging techniques, retrospective data collection, lack of control for confounding variables, and non-comparative study designs contribute significantly to the uncertainty and limited comparability of the findings. Consequently, the available evidence does not support causal or comparative interpretations regarding the relative safety of different vascular access devices.

Recently, a study found that thrombosis at the tip of a peripheral catheter (detected by ultrasound after administration of flucloxacillin or other antibiotics) was more frequent than those identified by clinical signs, as also seen in the Caparas et al. studies. Specifically, 100% of flucloxacillin infusions, 67% of other antibiotics, and 17% of the control group showed thrombosis on ultrasound, yet most of these were asymptomatic.22 This may explain the 100% thrombosis rate found by Scarano et al. (via ultrasound) and the 0% found by Caparas et al., who used only clinical signs. On the other hand, authors like Balsorano et al. found that CVCs also carry a risk of serious thrombosis, with rates between 2.2% and 5.9%.23 In the Scarano study, since only MLCs were used, no comparison between catheter types was possible.20

A central finding of this review is the lack of standardization in outcome definitions. Phlebitis was variably defined and often assessed without validated scales. Thrombosis was inconsistently investigated, ranging from symptom-triggered ultrasound to systematic daily imaging.24 These discrepancies significantly affect reported incidence rates and hinder meaningful comparison across studies. The absence of uniform diagnostic criteria represents a major barrier to evidence synthesis and to the development of evidence-based vascular access policies.

With regard to perfusion time, Caparas et al. indicate that the infusion was carried out over a period of 60min, noting, in addition, that the line was maintained by flushing it every 8–12h with 10cc of saline solution,19 data that is missing from both the work of Scarano et al.20 and Roszell and Jones.17 However, the study by Keogh et al. highlights that neither the increase in flush volume nor the frequency significantly altered the risk of peripheral catheter failure.25 Similarly, it was not reported whether the catheter length was different in the studies, as Scarano et al. used an 8cm catheter,20 and the study by Caparas and Hung did not indicate this.19

From a pathophysiological perspective, vancomycin-induced endothelial toxicity has been demonstrated in experimental models. In vitro studies by Drouet et al. confirmed that its endothelial toxicity depends more on concentration and exposure time than on pH alone, with significant cell mortality observed at concentrations above 2.5mg/ml, reaching nearly 100% at 5mg/ml after 24h.2,26

Understanding vancomycin's toxic mechanisms allows for a more precise analysis of how various factors influence vascular complications. Given its concentration and time dependent endothelial toxicity, vascular damage increases proportionally. This was observed by Scarano et al., where similar thrombosis rates occurred with both high (20mg/ml) and low (4mg/ml) concentrations, though later onset was noted with the more diluted solution.20 This may be due to non-chemical mechanisms, such as cellular stress from prolonged catheter presence. Studies on intravascular device complications have shown that prolonged peripheral catheter use increases the risk of phlebitis and thrombosis, even with non-vesicant drugs.27 Hence, low dilution or continuous infusion may worsen cellular stress regardless of drug properties.

Choosing the appropriate infusion method should be a specific, patient-centered process for nursing staff.17,28 Scarano et al. suggest that although dilution may delay thrombotic events, it does not eliminate the risk, which the authors interpreted as supporting CVC use for continuous vancomycin infusion, an interpretation also suggested in Roszell and Jones,17 and contrary to Caparas and Hu, who found no statistically significant difference in complications between MLCs and PICCs (a type of CVC), but reported lower insertion-related costs associated with MLC use.18 These findings were reinforced by Caparas himself in, where vancomycin administration via MLC in various doses rarely caused phlebitis.19 In the case of PICCs, it is important to bear in mind that the benefits of access must outweigh the most common risks associated with this type of catheter: bloodstream infection and thrombosis.29–32 Therefore, catheter choice should not depend solely on vesicant risk, but on a comprehensive risk-benefit evaluation.31–34 Some studies describe the use of midline catheters for vancomycin administration and report low rates of clinically evident complications; however, these findings derive from heterogeneous study designs and outcome definitions.16,31 Similarly, in 2011, the prestigious Infusion Nursing Society based in Massachusetts recommended clinical standards that included not using MLC in medications with a pH lower than 5, which means that vancomycin (pH 3.9)30 should be administered through a CVC. However, in 2016, the Society itself withdrew this recommendation, as it is no longer necessary to use a central line with drugs with a pH below 5.28 In addition, several authors have highlighted the need to update current recommendations to incorporate these findings.19,30 Caparas and Hung highlighted the need to re-evaluate traditional restrictions on the use of peripheral access for this antibiotic, arguing that its administration can be safe with appropriate access selection and clinical monitoring.19

In intensive care settings, vascular access complications extend beyond local inflammation or thrombosis. Loss of venous access may compromise antibiotic continuity, delay time-sensitive antimicrobial therapy, and necessitate repeated cannulation procedures. In high-acuity patients with limited vascular reserve, recurrent peripheral catheter failure may increase procedural burden, patient discomfort, and nursing workload.24 Moreover, unplanned catheter removal or malfunction may lead to escalation toward central access, exposing patients to additional mechanical and infectious risks. Therefore, vascular access decision-making in critical care should incorporate not only the physicochemical properties of vancomycin but also patient-specific factors such as vascular integrity, expected duration of therapy, hemodynamic stability, and institutional resources.24,34 However, the current evidence base does not adequately address these contextual and organizational outcomes, highlighting an important gap for future prospective research. Importantly, the studies included in this review did not systematically report or allow comparison of several clinically relevant operational outcomes, such as treatment interruptions, rates of peripheral catheter re-cannulation, unplanned escalation to central venous catheter placement, or the impact on nursing workload. The absence of these indicators limits the ability to evaluate the broader clinical and organizational consequences of vascular access failure during intravenous vancomycin therapy.

Future research should therefore incorporate standardized reporting of key indicators, including treatment continuity, catheter replacement rates, need for unplanned central access, and measures of nursing workload or procedural burden, in order to better characterize the real-world implications of vascular access device selection in critically ill patients.

In light of these considerations, the findings of this review should be interpreted primarily as exploratory and descriptive rather than as definitive comparative evidence on the optimal vascular access device for vancomycin administration. The very limited number of eligible studies, together with their small sample sizes, heterogeneous designs, and substantial risk of bias, markedly constrains the robustness and generalizability of the conclusions that can be drawn. Consequently, our results should be viewed as a preliminary mapping of the available evidence and of its methodological shortcomings, underscoring the need for well-designed, adequately powered prospective studies that systematically evaluate vascular complications according to catheter type and vancomycin administration protocol.

Study limitations

This study has several limitations. First, the number of studies addressing the use of different vascular access devices for intravenous vancomycin administration was very limited. In addition, the included studies did not adequately describe important clinical and procedural factors such as catheter length and catheter maintenance performed by nursing staff, both of which may influence vascular complications. Several relevant variables—including vancomycin concentration, infusion modality (continuous versus intermittent), duration of therapy, flushing protocols, and catheter dwell time—were inconsistently reported and not controlled across studies. These factors may independently contribute to endothelial injury and vascular complications, thereby limiting attribution of adverse outcomes specifically to the type of vascular access device used.

The methods used to diagnose thrombophlebitis also varied considerably, ranging from visual clinical assessment to systematic ultrasound evaluation. Furthermore, three of the four included studies presented serious or critical risk of bias, which substantially limits confidence in the available evidence.

Accordingly, the findings of this review should be interpreted cautiously and not as definitive comparative recommendations regarding the superiority or safety of any specific vascular access device. Rather, they should be understood as a descriptive overview of a fragmented and methodologically heterogeneous body of literature.

Conclusions

This scoping review mapped the limited body of clinical evidence evaluating vascular complications associated with intravenous vancomycin administration across different vascular access devices. The available studies are few, methodologically heterogeneous, and employ diverse definitions and diagnostic methods for vascular complications. As a result, the current literature does not allow robust comparative interpretations regarding the safety of different vascular access devices for vancomycin administration.

At present, the available evidence remains insufficient to support definitive recommendations regarding the optimal vascular access device for intravenous vancomycin administration. The findings primarily highlight substantial methodological variability and significant gaps in the reporting of vascular outcomes. Future research should prioritize standardized definitions, systematic diagnostic approaches, and well-designed prospective studies to better characterize vascular complications associated with vancomycin administration.

Declaration

The authors declare that they have not received any type of incentive in the form of scholarships, scholarships or financial support.

Financing

None.

Conflict of interest

The authors declare no conflict of interest.

Appendix A
Supplementary data

The followings are the supplementary data to this article:

Icono mmc1.doc
Icono mmc2.doc

References
[1]
M.J. Rybak.
The pharmacokinetic and pharmacodynamic properties of vancomycin.
Clin Infect Dis, 42 (2006), pp. S35-S39
[2]
M. Drouet, F. Chai, C. Barthélémy, G. Lebuffe, B. Debaene, B. Décaudin, et al.
Influence of vancomycin infusion methods on endothelial cell toxicity.
Antimicrob Agents Chemother, 59 (2015), pp. 930-934
[3]
S. Ballesteros-Peña, I. Fernández-Aedo, G. Vallejo-De la Hoz, J. Tønnesen, C. Miguelez.
Identificación de medicamentos intravenosos potencialmente irritantes.
Enferm Intensiva, 33 (2022), pp. 132-140
[4]
L. Hadaway, S.N. Chamallas.
Vancomycin: new perspectives on an old drug.
J Infus Nurs, 26 (2003), pp. 278-284
[5]
P. Blanco.
El catéter venoso de línea media: the midline venous catheter.
Rev Hosp Dr Emilio Ferreyra, 2 (2021), pp. e3-e9
[6]
K.R. Qin, M. Pittiruti, R.M. Nataraja, M. Pacilli.
Long peripheral catheters and midline catheters: insights from a survey of vascular access specialists.
J Vasc Access, 22 (2021), pp. 905-910
[7]
G.B. Deutsch, S.A. Sathyanarayana, N. Singh, J. Nicastro.
Ultrasound-guided placement of midline catheters in the surgical intensive care unit: a cost-effective proposal for timely central line removal.
J Surg Res, 191 (2014), pp. 1-5
[8]
E.B. Nielsen, L. Antonsen, C. Mensel, N. Milandt, L.S. Dalgaard, B.S. Illum, et al.
The efficacy of midline catheters: a prospective, randomized, active-controlled study.
Int J Infect Dis, 102 (2021), pp. 220-225
[9]
R. Dawson, L. Moureau.
Midline catheters: an essential tool in CLABSI reduction [Internet].
Infection Control Today, (2013),
[10]
A. Mushtaq, B. Navalkele, M. Kaur, A. Krishna, A. Saleem, N. Rana, et al.
Comparison of complications in midlines versus central venous catheters: are midlines safer than central venous lines?.
Am J Infect Control, 46 (2018), pp. 788-792
[11]
M. Urtecho, V.D. Torres Roldan, T. Nayfeh, N.R. Espinoza Suarez, N. Ranganath, P. Sampathkumar, et al.
Comparing complication rates of midline catheter vs peripherally inserted central catheter: a systematic review and meta-analysis.
Open Forum Infect Dis, 10 (2023),
[12]
A.C. Tricco, E. Lillie, W. Zarin, K.K. O’Brien, H. Colquhoun, D. Levac, et al.
PRISMA Extension for Scoping Reviews (PRISMA-ScR): checklist and explanation.
Ann Intern Med, 169 (2018), pp. 467-473
[13]
O.D. Lopez-Cortes, A. Betancourt-Núñez, M.F. Bernal, B. Vizmanos.
Scoping reviews: una nueva forma de síntesis de la evidencia.
Investig Educ Med, 11 (2022), pp. 98-104
[14]
J. McGowan, S. Straus, D. Moher, E.V. Langlois, K.K. O’Brien, T. Horsley, et al.
Reporting scoping reviews—PRISMA ScR extension.
J Clin Epidemiol, 123 (2020), pp. 177-179
[15]
Cochrane. Risk of Bias 2 (RoB 2) tool [Internet]. Cochrane Methods. Available from: https://www.cochrane.org/learn/courses-and-resources/cochrane-methodology/risk-bias/about-risk-bias-2-rob-2 [cited 7.6.26].
[17]
S. Roszell, C. Jones.
Intravenous administration issues: a comparison of intravenous insertions and complications in vancomycin versus other antibiotics.
J Infus Nurs, 33 (2010), pp. 112-118
[18]
J.V. Caparas, J.P. Hu.
Safe administration of vancomycin through a novel midline catheter: a randomized, prospective clinical trial.
J Vasc Access, 15 (2014), pp. 251-256
[19]
J.V. Caparas, H.-S. Hung.
Vancomycin administration through a novel midline catheter: summary of a 5-year, 1086-patient experience in an urban community hospital.
J Assoc Vasc Access, 22 (2017), pp. 38-41
[20]
M. Scarano, S. D’Arrigo, S. De Letteriis, S. Grasso, M. Pittiruti, G. Scoppettuolo.
Risk of thrombophlebitis associated with continuous peripheral infusion of vancomycin: the effect of dilution.
J Vasc Access, 25 (2024), pp. 107-112
[21]
S.M. Park, I.S. Jeong, S.S. Jun.
Identification of risk factors for intravenous infiltration among hospitalized children: a retrospective study.
PLOS ONE, 11 (2016), pp. e0158045
[22]
A.C. Bulmer, R. Nightingale, W. Hewage, G. Keijzers, P.J. Snelling.
Ultrasound evaluation of peripheral intravenous catheter thrombus formation associated with intravenous flucloxacillin administration: a prospective observational pilot study.
Aust J Ultrasound Med, 28 (2025), pp. e12414
[23]
P. Balsorano, G. Virgili, G. Villa, M. Pittiruti, S. Romagnoli, A.R. De Gaudio, et al.
Peripherally inserted central catheter-related thrombosis rate in modern vascular access era-when insertion technique matters: a systematic review and meta-analysis.
J Vasc Access, 21 (2020), pp. 45-54
[24]
N. Marsh, J. Webster, A.J. Ullman, G. Mihala, M. Cooke, V. Chopra, et al.
Peripheral intravenous catheter non-infectious complications in adults: a systematic review and meta-analysis.
J Adv Nurs, 76 (2020), pp. 3346-3362
[25]
S. Keogh, J. Flynn, N. Marsh, G. Mihala, K. Davies, C. Rickard.
Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients.
[26]
M. Drouet, E. Cuvelier, F. Chai, S. Genay, P. Odou, B. Décaudin.
Disturbance of vancomycin infusion flow during multidrug infusion: influence on endothelial cell toxicity.
Antibiotics (Basel), 11 (2022), pp. 16
[27]
K.A. Cawcutt, R.J. Hankins, T.A. Micheels, M.E. Rupp.
Optimizing vascular-access device decision-making in the era of midline catheters.
Infect Control Hosp Epidemiol, 40 (2019), pp. 674-680
[28]
L.A. Gorski.
The 2016 infusion therapy standards of practice.
Home Healthc Now, 35 (2017), pp. 10
[29]
V. Chopra, J.C. O’Horo, M.A.M. Rogers, D.G. Maki, N. Safdar.
The risk of bloodstream infection associated with peripherally inserted central catheters compared with central venous catheters in adults: a systematic review and meta-analysis.
Infect Control Hosp Epidemiol, 34 (2013), pp. 908-918
[30]
N.L. Moureau.
Is the pH of vancomycin an indication for central venous access?.
J Vasc Access, 15 (2014), pp. 249-250
[31]
M. Abdulelah, O. Haider, H. Abdulelah, K.T. Jamouss, T.L. Higgins.
Venous access devices (Review).
Med Int (Lond), 5 (2025), pp. 1-10
[32]
J.M. Porter, R.B. Rutherford, G.P. Clagett, J.J. Cranley, T.F. O’Donnell, S. Raju, et al.
Reporting standards in venous disease.
J Vasc Surg, 8 (1988), pp. 172-181
[33]
S. Manrique-Rodríguez, I. Heras-Hidalgo, M.S. Pernia-López, A. Herranz-Alonso, M.C. Del Río Pisabarro, M.B. Suárez-Mier, et al.
Standardization and chemical characterization of intravenous therapy in adult patients: a step further in medication safety.
Drugs R D, 21 (2021), pp. 39-64
[34]
N. Marsh, E.N. Larsen, M. Takashima, T. Kleidon, S. Keogh, A.J. Ullman, et al.
Peripheral intravenous catheter failure: a secondary analysis of risks from 11,830 catheters.
Copyright © 2026. The Authors