Buscar en
Actas Urológicas Españolas
Toda la web
Inicio Actas Urológicas Españolas Deteccion del cáncer de próstata en el rango de psa entre 3 y 3,9 ng/ml
Información de la revista
Vol. 26. Núm. 4.
Páginas 271-274 (Enero 2002)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 26. Núm. 4.
Páginas 271-274 (Enero 2002)
Deteccion del cáncer de próstata en el rango de psa entre 3 y 3,9 ng/ml
Visitas
920
J.M. Gómez De Vicente1, M. Luján Galán, A. Páez Borda, I. Romero Cagigal, A. Moreno Santurino, D. Santos Arrontes, A. Berenguer Sánchez
Servicio de Urología. Hospital Universitario de Getafe. Madrid
Este artículo ha recibido
Información del artículo
Resumen
Objetivo

En este estudio se analiza el beneficio de reducir el valor de PSA para el cual se indica una biopsia prostática de 4 a 3 ng/ml.

Material Y Métodos

Partimos de 4.278 pacientes procedentes de un programa de screening de cáncer de próstata. Consideramos 1.217 actuaciones en las que se realizó determinación sérica de PSA, indicando la biopsia prostática cuando el PSA era =3 ng/ml. En ningún caso el TR (TR) fue la indicación para realizar la misma. Todas las biopsias fueron sextantes y ecodirigidas por vía transrectal. Comparamos el rendimiento de la biopsia al emplear como puntos de corte 4 y 3 ng/ml.

Resultados

De Las 1.217 actuaciones realizadas, 947 presentaron valores de PSA inferiores a 3 ng/ml, 80 entre 3 y 3,9 ng/ml y 190 por encima de 4 ng/ml. De los 270 pacientes que componen estos dos últimos grupos, 189 (70%) se sometieron a una biopsia prostática. Con el nivel de corte establecido de forma habitual (4 ng/ml) se indicaron 134 biopsias y se detectaron 28 cánceres (valor predictivo positivo 20,9%). Sin embargo al reducir el punto de corte a 3 ng/ml el número de biopsias indicadas ascendió a 189, detectando 34 cánceres (valor predictivo positivo 17,9%). El descenso en el rendimento de la biopsia no fue significativo (OR=0,89). De los 6 tumores detectados al reducir el punto de corte, ninguno era palpable o visible (T1c), todos presentaron un score de Gleason menor de 7 y la mitad cumplían criterios de tumor clinicamente relevante.

Conclusiones

La Reducción del valor de PSA a 3 ng/ml como punto de corte para indicar una biopsia prostática ha supuesto un incremento en la tasa de detección del cáncer de próstata de un 21,4%, sin reducir significativamente el rendimiento de la biopsia. Por tanto, creemos que la inclusión del grupo de pacientes con PSA entre 3 y 3,9 ng/ml como candidatos a biopsiar es importante en un programa de screening precoz de cáncer de próstata.

Palabras Clave:
Cáncer de próstata
Antígeno Específico Prostático
Screening
Abstract
Objetive

In our study, we analize the benefit of lowering the PSA cutoff point for which a prostate biopsy is indicated from 4 to 3 ng/ml.

Materials And Methods

We have considered 4.278 individuals coming from a prostate cancer screening program. We studied 1.217 interventions in wich PSA was deteminated, indicating the prostate biopsy with PSA =3 ng/ml. Digital rectal examination was never the indication for the biopsy. All biopsies were sextant and assisted by transrectal ultrasound. We compared the performance of the biopsy using 4 and 3 ng/ml as cut points.

Results

Of the 1.217 interventions performed, 947 had PSA values lower than 3 ng/ml, 80 between 3 and 3.9 ng/ml and 190 over 4 ng/ml. A total of 189 patients (70% of these two last groups) underwent a prostate biopsy. With 4 ng/ml as the cut point, 134 biopsies were indicated, detecting 28 cancers (positive predictive value 20.9%). However 189 biopsies were indicated and 34 cancers detected by lowering the cut point to 3 ng/ml (positive predictive value 17,9%). The reduction in the biopsy performance was not statistically significant (OR=0,89). None of the 6 additional cancers detected was palpable or ecographically visible (T1c), all of them had a Gleason score under 7 and half of them could be considered clinically relevant.

Conclusions

Lowering PSA cutoff point from 4 to 3 ng/ml improved the detection rate in 21.4% not jeopardizing the biopsy performance. Therefore, we think that the group of patients with PSA between 3 and 3.9 ng/ml as candidates for prostate biopsy, should be included in screening programs.

Key Words:
Prostate Cancer
Prostate Specific Antigen
Screening

Artículo

Opciones para acceder a los textos completos de la publicación Actas Urológicas Españolas
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Actas Urológicas Españolas

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos