metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Valoración del tromboembolismo pulmonar relacionado con infección SARS-CoV-2 a...
Journal Information
Vol. 42. Issue 4.
Pages 218-222 (July - August 2023)
Share
Share
Download PDF
More article options
Visits
417
Vol. 42. Issue 4.
Pages 218-222 (July - August 2023)
Original
Valoración del tromboembolismo pulmonar relacionado con infección SARS-CoV-2 activa en pacientes embarazadas
Assessment of pulmonary embolism related to active SARS-CoV-2 infection in pregnant women
Visits
417
A. Moreno-Ballesterosa,
Corresponding author
anamoreno_ballesteros@hotmail.com

Autor para correspondencia.
, Á.C. Rebollo-Aguirrea, I. Bolívar-Roldánb, T. Busquierc, E. Sanchez-de Moraa, A. Jimenez-Heffernana
a Unidad de Medicina Nuclear, Hospital Universitario Juan Ramón Jiménez, Huelva, España
b Unidad de Medicina Nuclear, Hospital Universitario Virgen Macarena, Sevilla, España
c Unidad de Radiodiagnóstico, Hospital Universitario Virgen Macarena, Sevilla, España
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (3)
Show moreShow less
Tables (1)
Tabla 1. Resultados y características de las pacientes incluidas
Resumen
Objetivo

Analizar la muestra de pacientes embarazadas a las que se les realizó una gammagrafía de perfusión pulmonar para descartar la sospecha de tromboembolismo pulmonar (TEP) durante el ingreso en nuestro centro por infección aguda por COVID-19.

Material y métodos

A todas las pacientes (n=5) se les realizó una gammagrafía SPECT con dosis reducida (111MBq) de 99mTc-macroagregados de albúmina. Las imágenes obtenidas se interpretaron comparando los hallazgos con la imagen radiológica según criterios PISAPED.

Resultados

De las 5 pacientes, tan solo en una se diagnosticó TEP. En 2 pacientes los hallazgos patológicos de la gammagrafía fueron atribuibles a alteraciones radiológicas por neumonía COVID-19, y otras 2 mostraron una perfusión pulmonar normal.

Conclusión

Dado lo inespecífico de las manifestaciones clínicas y los valores del dímero D dentro de la COVID-19, así como su similitud con los de TEP, la gammagrafía de perfusión pulmonar, por su alta sensibilidad y menor irradiación que la TC, tiene un papel crucial en el despistaje de TEP en estas pacientes. Los resultados obtenidos son de especial relevancia, a pesar del número limitado de pacientes, dada la ausencia de publicaciones científicas en este grupo de pacientes dentro de la situación excepcional por la pandemia de COVID-19.

Palabras clave:
Tromboembolismo pulmonar
Embarazo
Gammagrafía
SPECT
COVID-19
SARS-CoV-2
Abstract
Aim

To analyze the sample of pregnant patients who underwent pulmonary perfusion scintigraphy to rule out the pulmonary embolism (PE) suspicion during the acute COVID-19 infection hospitalization period in our hospital.

Material and methods

SPECT scintigraphy with a reduced dose (111MBq) of 99mTc-macroaggregated albumin was performed in all of the patients (n=5). The obtained images were interpreted by comparing the findings with the radiological images according to the PISAPED criteria.

Results

Only one of the 5 patients was diagnosed with PE. Two patients obtained pathological findings of the scintigraphy attributable to radiological alterations due to COVID-19 pneumonia, and the other 2 had normal pulmonary perfussion.

Conclusion

Given the non-specific features of the clinical manifestations and D-dimer values in COVID-19, as well as their similarity to those of PE, the pulmonary perfusion scintigraphy plays a crucial role in the screening of PE in these patients due to its high sensitivity and lower irradiation compared to CT. Despite the limited number of patients, the results obtained have special relevance related to the absence of scientific publications on this group of patients within the context of COVID-19 pandemic exceptional situation.

Keywords:
Pulmonary embolism
Pregnancy
Scintigraphy
SPECT
COVID-19
SARS-CoV-2

Article

These are the options to access the full texts of the publication Revista Española de Medicina Nuclear e Imagen Molecular
Member
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Subscribe
Subscribe to

Revista Española de Medicina Nuclear e Imagen Molecular

Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Price 19.34 €

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
Article options
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos