Buscar en
Revista Española de Anestesiología y Reanimación
Toda la web
Inicio Revista Española de Anestesiología y Reanimación Monitorización con espectrograma del sistema de monitorización BIS VISTA™ en...
Información de la revista
Vol. 65. Núm. 8.
Páginas 473-476 (Octubre 2018)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
155
Vol. 65. Núm. 8.
Páginas 473-476 (Octubre 2018)
Caso clínico
Monitorización con espectrograma del sistema de monitorización BIS VISTA™ en una hemisferectomía funcional
Density spectral array of BIS VISTA™ monitoring system in a functional hemispherectomy
Visitas
155
C. Luis
Autor para correspondencia
61307@parcdesalutmar.cat

Autor para correspondencia.
, E. Vilà, L. Moltó, A. Pardo, J.L. Fernández Candila, S. Pacreu
Departamento de Anestesiología y Reanimación, Hospital del Mar, Parc de Salut Mar, Barcelona, España
Contenido relaccionado
C. Luis, E. Vilà, L. Moltó, A. Pardo, J.L. Fernández Candil, S. Pacreu
Este artículo ha recibido
Disponible módulo formativo: Volumen 65 - Número 8. Saber más
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (1)
Resumen

Presentamos el caso de una paciente adulta con epilepsia farmacorresistente secundaria a una inflamación extensa del hemisferio cerebral derecho, que fue programada para realizársele una hemisferectomía funcional. Se trata de una cirugía habitual en pediatría, pero con pocas publicaciones en pacientes adultos. Durante el intraoperatorio se utilizó el espectrograma perteneciente al sistema de monitorización VISTATM del índice biespectral bilateral (BIS). Se objetivó un aumento de potencia en las bandas de baja frecuencia (0,1-4Hz) y en las bandas alfa (8-12Hz) del hemisferio cerebral derecho, donde se encontraba el foco epileptógeno. Durante la desconexión del lóbulo frontal se observó una marcada disminución de potencia en dichas bandas, sin objetivarse cambios durante la desconexión de las otras áreas cerebrales. Pensamos que se necesitan más estudios para saber si el espectrograma puede ser una herramienta útil para monitorizar la efectividad de la hemisferectomía funcional.

Palabras clave:
Espectrograma
Índice biespectral bilateral
Hemisferectomía funcional
Abstract

We present the case of an adult patient with drug-resistant epilepsy caused by extensive inflammation in the right cerebral hemisphere. She was scheduled to undergo right functional hemispherectomy, which is common in pediatric surgery, but about which few studies have been published with respect to adult patients. During the intraoperative period, the density spectral array of the bilateral bispectral index (BIS) VISTATM monitoring system was used. We observed a power increase in low frequency (0.1-4Hz) and alpha bands (8-12Hz) in the right hemisphere, where the epileptogenic focus was. During disconnection from the frontal lobe, there was a marked decrease of power in low frequency and alpha bands on the right side, with no changes during disconnection from other areas of the brain. We think that further studies are needed to determine whether the density spectral array can be a useful tool for monitoring the effectiveness of functional hemispherectomy.

Keywords:
Density spectral array
Bilateral bispectral index
Functional hemispherectomy

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Anestesiología y Reanimación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Anestesiología y Reanimación

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
Herramientas
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos