Flow diversion for renal and splenic artery aneurysms using the derivo embolisation device: A retrospective study

Uso del diversor de flujo Derivo Embolisation Device para aneurismas de las arterias renal y esplénica: estudio retrospectivo
Visits
755
C. Piñanaa,
Corresponding author
capiplaza@gmail.com

Corresponding author.
, R. González-Costerob, J. Villalbac, A. Illaded, J. González-Plazad, M. Rengela, M. Pérez-Lafuentee
a Unidad de Radiología Intervencionista, Hospital Clínico Universitario de Valencia, Valencia, Spain
b Unidad de Radiología Intervencionista, Hospital Universitario Puerta de Hierro, Madrid, Spain
c Unidad de Radiología Intervencionista, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
d Unidad de Radiología Intervencionista, Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, Spain
e Unidad de Radiología Intervencionista, Hospital Universitari Vall d’Hebron, Barcelona, Spain
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Abstract
Purpose

Visceral artery aneurysms are increasingly diagnosed and carry a substantial rupture risk. Endovascular treatment is often preferred over surgery, yet complex anatomy and side-branch involvement may limit embolisation. As flow-diverter stents have addressed similar challenges in intracranial aneurysms, we aimed to evaluate their performance for renal and splenic artery aneurysms and report a multicentric experience using the Derivo Embolisation Device.

Methods

We retrospectively analysed all patients treated with Derivo devices in three high-volume centres between 2021 and 2024. We collected data on symptoms, aneurysm characteristics, occlusion rates, complications and morbidity.

Results

Thirty-three visceral artery aneurysms were treated: 60.6% splenic and 39.4% renal. Mean maximum diameter of the lesions was 19 mm. At 12-month follow-up, complete occlusion was achieved in 21/30 cases (70%), with an additional 13% showing minimal filling; 87.5% of stents and side branches remained patent. Two technical issues occurred (6%). Major adverse events affected four patients (12.5%) due to stent occlusion and subsequent end-organ ischaemia. Higher overall incidence of adverse events was found in the adjunctive-coiling subgroup. No deaths were reported.

Conclusion

Flow-diverter treatment of visceral artery aneurysms using the Derivo Embolisation Device appears effective and feasible, achieving high occlusion rates. However, safety regarding organ preservation warrants further evaluation, emphasising strict antiplatelet management and the potential benefits of stand-alone flow diversion. Prospective trials are needed to clearly define their therapeutic role.

Keywords:
Visceral aneurysm
Endovascular procedures
Embolization
Aneurysm occlusion
Flow diverter
Derivo Embolisation Device
Resumen
Introducción

Los aneurismas de las arterias viscerales se diagnostican con mayor frecuencia y presentan riesgo considerable de rotura. El tratamiento endovascular suele preferirse frente a la cirugía, aunque la anatomía compleja y la implicación de ramas adyacentes puede limitar la embolización. Dado que los stents diversores de flujo han superado retos similares en aneurismas intracraneales, evaluamos su eficacia en aneurismas renales y esplénicos en una experiencia multicéntrica con Derivo Embolisation Device.

Métodos

Se analizaron retrospectivamente todos los pacientes tratados con Derivo en tres centros entre 2021 y 2024. Se recopilaron datos clínicos, características de los aneurismas, tasas de oclusión, complicaciones y morbilidad.

Resultados

Se trataron 33 aneurismas viscerales: 60,6 % esplénicos y 39,4 % renales. Diámetro máximo medio: 19 mm. A los 12 meses, se logró oclusión completa en 21/30 casos (70 %) y un 13 % adicional presentó relleno mínimo. La permeabilidad final del stent fue 87,5 %, y todas las ramas cubiertas permanecieron permeables. Se documentaron dos problemas técnicos (6 %). Los eventos adversos mayores (oclusión del stent e isquemia del órgano) afectaron a 4 pacientes (12,5 %), con mayor incidencia en el subgrupo de coiling adicional. No hubo mortalidad.

Conclusión

El tratamiento con diversores de flujo usando Derivo Embolisation Device parece eficaz y factible, con altas tasas de oclusión. La seguridad respecto a eventos trombóticos requiere mayor evaluación, destacando la importancia de un manejo estricto de la antiagregación y el posible beneficio del diversor de flujo sin coiling adicional. Se necesitan ensayos prospectivos para definir claramente su papel terapéutico en arterias viscerales.

Palabras clave:
Aneurismas viscerales
Procedimiento endovascular
Embolización
Exclusión aneurisma
Diversor de flujo
Derivo Embolisation Device

Article

These are the options to access the full texts of the publication Radiología (English Edition)
Subscriber
Subscriber

If you already have your login data, please click here .

If you have forgotten your password you can you can recover it by clicking here and selecting the option “I have forgotten my password”
Purchase
Purchase article

Purchasing article the PDF version will be downloaded

Purchase now
Contact
Phone for subscriptions and reporting of errors
From Monday to Friday from 9 a.m. to 6 p.m. (GMT + 1) except for the months of July and August which will be from 9 a.m. to 3 p.m.
Calls from Spain
932 415 960
Calls from outside Spain
+34 932 415 960
E-mail
References
[1]
R. Loffroy, S. Favelier, P. Pottecher, P.-Y. Genson, L. Estivalet, S. Gehin, et al.
Endovascular management of visceral artery aneurysms: When to watch, when to intervene?.
World J Radiol, 7 (2015), pp. 143-148
[2]
M. Rossi, M. Krokidis, E. Kashef, B. Peynircioglu, M.A. Tipaldi.
CIRSE standards of practice for the endovascular treatment of visceral and renal artery aneurysms and pseudoaneurysms.
CardiovascIntervent Radiol, 47 (2024), pp. 26-35
[3]
H.K. Kok, H. Asadi, M. Sheehan, M.F. Given, M.J. Lee.
Systematic review and single-center experience for endovascular management of visceral and renal artery aneurysms.
J Vasc Interv Radiol, 27 (2016), pp. 1630-1641
[4]
Y. Zhang, D. Xiang, Q. Lu, M. Wu, J. Cui.
A systematic review and meta-analysis of the performance of flow-diverting stents in the treatment of peripheral and visceral artery aneurysms.
Catheter Cardiovasc Interv, (2020), pp. 1-9
[5]
P. Rabuffi, A. Bruni, E.G.M. Antonuccio, C. Ambrogi, S. Vag-narelli.
Treatment of visceral artery aneurysms and pseudoaneurysms with the use of cerebral flow diverting stents: initial experience.
CVIR Endovasc, 3 (2020), pp. 48
[6]
T. Becske, D.F. Kallmes, I. Saatci, C.G. McDougall, I. Szikora, G. Lanzino, et al.
Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.
Radiology, 267 (2013), pp. 858-868
[7]
P.K. Nelson, P. Lylyk, I. Szikora, S.G. Wetzel, I. Wanke, D. Fiorella.
The Pipeline Embolization Device for the intracranial treatment of aneurysms.
Am J Neuroradiol, 32 (2011), pp. 34-40
[8]
G. Zhou, M. Su, Y.Q. Zhu, M.-H. Li.
Efficacy of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis.
World Neurosurg, 85 (2016), pp. 252-262
[9]
D. Adrahtas, P. Jasinski, G. Koullias, D. Fiorella, A.K. Tassio-poulos.
Endovascular treatment of a complex renal artery aneurysm using coils and the pipeline embolization device in a patient with a solitary kidney.
Ann Vasc Surg, 36 (2016), pp. 291.e5-291.e9
[10]
D. Colombi, F.C. Bodini, M. Bossalini, B. Rossi, E. Michieletti.
Extracranial visceral artery aneurysms/pseudoaneurysms repaired with flow diverter device developed for cerebral aneurysms: preliminary results.
Ann Vasc Surg, 53 (2018), pp. 272.e1-272.e9
[11]
V. Semeraro, R. Arpesani, G. Della Malva, F. Gasparrini, S. Vidali, M.P. Ganimede, et al.
Flow diverter treatment for renal artery aneurysms: one-year follow-up of a multicentric preliminary experience.
Diagn Interv Radiol, 28 (2022), pp. 609-615
[12]
D. Ley, R. Mühl-Benninghaus, U. Yilmaz, H. Körner, G.F.M. Catta-neo, W. Mailänder, et al.
The Derivo Embolization Device, a second generation flow diverter for the treatment of intracranial aneurysms, evaluated in an elastase-induced aneurysm model.
Clin Neuroradiol, 27 (2017), pp. 335-343
[13]
C.J. O’Kelly, T. Krings, D. Fiorella, T.R. Marotta.
A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents.
Interv Neuroradiol, 16 (2010), pp. 133-137
[14]
O. Khalilzadeh, M.O. Baerlocher, P.B. Shyn, B.L. Connolly, A.M. Devane, C.S. Morris, et al.
Proposal of a new Adverse Event classification by the Society of Interventional Radiology Standards of Practice Committee.
J Vasc Interv Radiol, 28 (2017), pp. 1432-1437
[15]
C. Piñana, S. Remollo, J. Zamarro, M. Werner, M. Espi-nosa de Rueda, P. Vega, et al.
Derivo embolization device for intracranial aneurysms: a Spanish multicenter retrospective study.
J Neurointerv Surg, (2022), pp. 1-6
[16]
A. Monteiro, S.M. Burke, A.A. Baig, S. Khan, J.M. Cappuzzo, M. Waqas, et al.
A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment.
J Neurointerv Surg, 14 (2022), pp. 1125-1129
[17]
J. Maingard, A. Lamanna, H.K. Kok, D. Ranatunga, R. Ravi, R.V. Chandra, et al.
Endovascular treatment of visceral artery and renal aneurysms (VRRA) using a constant mesh density flow diverting stent.
CVIR Endovasc, 2 (2019), pp. 15
[18]
G.S. Sfyroeras, I. Dalainas, T.G. Giannakopoulos, K. Antonopoulos, J.D. Kakisis, C.D. Liapis.
Flow-diverting stents for the treatment of arterial aneurysms.
J Vasc Surg, 56 (2012), pp. 839-846
[19]
R.A. Chaer, C.J. Abularrage, D.M. Coleman, M.H. Eslami, V.S. Kash-yap, C. Rockman, et al.
The Society for Vascular Surgery clinical practice guidelines on the management of visceral aneurysms.
J Vasc Surg, 72 (2020), pp. 3S-39S
[20]
G. Zhou, M. Su, Y.L. Yin, M.-H. Li.
Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis.
Neurosurg Focus, 42 (2017), pp. E17
[21]
A.M. Belli, G. Markose, R. Morgan.
The role of interventional radiology in the management of abdominal visceral artery aneurysms.
Cardiovasc Intervent Radiol, 35 (2012), pp. 234-243