Journal Information
Vol. 27. Issue 6.
Pages 277-280 (August - September 1991)
Share
Share
Download PDF
More article options
Vol. 27. Issue 6.
Pages 277-280 (August - September 1991)
Full text access
Utilidad de la pulsioximetría durante la broncofibroscopia
Usefulness of pulseoxymetry during bronchofiberoscopy
Visits
3161
L.M. Hernández Blasco, V. Villena Garrido, I. Sánchez Hernández, E. de Miguel Poch, J. Alfaro Abreu, C. Álvarez Martínez, P. Martín Escribano
Servicio de Neumologia. Hospital 12 de Octubre. Madrid
This item has received
Article information
Abstract
Bibliography
Download PDF
Statistics

El estudio se diseñó para evaluar la utilidad de la pulso oximetría en la detección de hipoxemia durante la broncofi-broscopia (BF). Se monitorizó de forma no invasiva y continua la saturación de oxígeno de la hemoglobina arterial (Sa02%) y la frecuencia cardíaca durante la realización de la BF a 102 pacientes adultos. Se observó un descenso medio de la Sa02% de 2,5% (DE = 2,5%, intervalo O a 14%), sin encontrarse diferencia estadísticamente significativa entre las diferentes fases en que se dividió la exploración o al separar a los pacientes según se obtuvieran muestras de tejido pulmonar mediante biopsia transbronquial (n = 36) o no (n = 66). En diez pacientes se objetivaron Sa02% inferiores a 85% durante la BF, que se corrigieron con la administración de oxígeno suplementario. Se exponen aquellas circunstancias que pueden interferir en la validez de las lecturas del pulso oxímetro y las posibles soluciones. Aconsejamos la utilización de la pulso oximetría para la monitorización durante la BF de los pacientes de alto riesgo, lo que permite poder hacer una corrección idónea e inmediata de las posibles fases hipoxémicas.

This study was designed to evaluate the usefulness of pul-sioxymetry for the detection of hypoxemia during bronchofiberoscopy. In a series of 102 adult patients a noninvasive continuous monitoring of oxygen saturation of arterial hemo-globin (Sa02%) and heart rate was performed during a bron-chofibroscopic examination. There was a mean decrease in Sa02% of 2.5% (SD: 2.5%, range 0 to 14%) but there were no statistically significant dilferences during the different steps of the exploration and the decrease was comparable if the patients were divided into those who underwent transpul-monary biopsy (n = 36) and those did not (n = 66). In ten patients Sa02 was lower than 85% during bronchoscopy and was corrected with additional oxygen supply. All possible circumstances that may interfere the validity of pulsioxymetry measurements are discussed along with their possible solu-tion. We advise the use of pulsioxymetry monitoring during bronchoscopy in high risk patients since it allows to a rapid and effective correction of all hypoxemic phases.

Full text is only aviable in PDF
Bibliografía
[1.]
S. Ikeda, bronchofiberscope. Flexible.
Keio J Med, 1 (1968), pp. 1-18
[2.]
J.W. Sokolowstky, L.W. Burgher, F.L. Jones, J.R. Patterson, P.A. Selecky.
Guidelines for (fiberoptic bronchoscopy in adults.
Am Rev Respir Dis, 136 (1987), pp. 1-066
[3.]
I. Blanco, L. Palenciano.
Influencia de la broncofibroscopia en los gases en sangre arterial.
Arch Bronconeumol, 12 (1976), pp. 76-78
[4.]
E. Harnick, L. Kulczycki, M. Gomes.
Transcutaneous oxygen monitoring during bronchoscopy and washout for cystic fibrosis.
Anesth Analg, 62 (1983), pp. 357-362
[5.]
L.M. Hernández Blasco, J.L. Guerra Vales, M.A. Juretschke Moragues, et al.
Medida no invasiva de la saturación arterial de oxígeno mediante pulsioximetría.
Aren Bronconeumol, 25 (1989), pp. 197-199
[6.]
J. Rohwedder.
Enticements for fruitless bronchoscopy.
Chest, 96 (1989), pp. 708-710
[7.]
R. Sen, T. Walsh.
Bronchoscopy. Enough or too much?.
Chest, 96 (1989), pp. 710-712
[8.]
W. Credle, J. Smiddy, R. Elliot.
Complications of fiberoptic bronchoscopy.
Am Rev Respir Dis, 109 (1974), pp. 67-72
[9.]
F. Simpson, A. Arnold, A. Purvis, P. Belfield, M. Muers, N. Cooke.
Postal survey of bronehoscopic practice by physicians in the United Kingdom.
Thorax, 41 (1986), pp. 311-317
[10.]
P. Suratt, J. Smiddy, D. Gruber.
Deaths and complications associated with fiberoptic bronchoscopy.
Chest, 69 (1976), pp. 747-751
[11.]
W. Pereira, D. Kownat, G. Snider.
A prospective cooperative study of complications following flexible fiberoptic bronchoscopy.
Chest, 73 (1978), pp. 813-816
[12.]
R. Albertini, J. Harrell, K. Moser.
Management of arterial hypoxemia induced by fiberoptic bronchoscopy.
Chest, 67 (1975), pp. 134-136
[13.]
C. Lindholm, B. Ollman, J. Snyder, E. Millen, A. Grenvik.
Cardiorespiratory effects of flexible fiberoptic bronchoscopy in critically ill patients.
Chest, 74 (1978), pp. 362-368
[14.]
R. Albertini, J. Harrell, K. Moser.
Hypoxemia during fiberoptic bronchoscopy.
Chest, 65 (1974), pp. 117
[15.]
B. Brach, G. Escano, J. Harrell, K. Moser.
Ventilation-perfusion alterations induced by fiberoptic bronchoscopy.
Chest, 69 (1976), pp. 335-337
[16.]
D. Shrader, S. Lakshminarayan.
The effect of fiberoptic bronchoscopy on cardiac rhythm.
Chest, 73 (1978), pp. 821-824
[17.]
C. Payne, P. Goyal, S. Gupta.
Effects of transoral and transnasal fiberoptic bronchoscopy on oxygenation and cardiac rhythm.
Endoscopy, 18 (1986), pp. 1-3
[18.]
M. Yelderman, W. New.
Evaluation of pulse oximetry.
Anesthesiology, 59 (1983), pp. 349-352
[19.]
A. Warley, J. Mitchell, J. Stradling, et al.
Evaluation of the Ohmeda 3700 pulse oximeter.
Thorax, 42 (1987), pp. 892-896
[20.]
B. Nickerson, C. Sarkisian, K. Tremper.
Bias and precisión of pulse oximeters and arterial oximeters.
Chest, 93 (1988), pp. 515-517
[21.]
H. Wiedemann, K. McCarthy.
Noninvasive monitoring of oxygen and carbón dioxide.
Clin Chest Med, 10 (1989), pp. 239-254
[22.]
B. Kataria, R. Lampkins.
Nail polish does not affect pulse oximeter saturation.
Anesth Analg, 65 (1986), pp. 824
[23.]
A.S. Rubin.
Nail polish color can affect pulse oximeter saturation.
Anesthesiology, 68 (1988), pp. 825
[24.]
L. Hernández Blasco, V. Villena Garrido, C. Alvarez Martínez.
Monitorización no invasiva y continuada de la oxigenación arterial durante la broncofibroscopia.
Aroh Bronconeumol, 25 (1989), pp. 247
[25.]
J. Brodsky, M. Shulman, M. Swan, J. Mark.
Pulse oximetry during one-lung ventilation.
Anesthesiology, 63 (1985), pp. 212-214
[26.]
M. Ghows, M. Rosen, M. Chuang, H. Sacks, A. Teirstein.
Transcutaneous oxygen monitoring during fiberoptic bronchoscopy.
Chest, 89 (1986), pp. 543-544
[27.]
A. Herrejón Silvestre, M. Simó Mompó, M. Pérez Gonzalvo, E. Chiner Vives, J. Marín Pardo.
Comparación de la presión arterial y transcutánea de oxígeno en la fibrobroncoscopia.
Arch Bronconeumol, 25 (1989), pp. 80-83
Copyright © 1991. Sociedad Española de Neumología y Cirugía Torácica
Archivos de Bronconeumología
Article options
Tools

Are you a health professional able to prescribe or dispense drugs?