Regístrese
¿Aún no está registrado?
Información relevante

Consulte los artículos y contenidos publicados en este medio, además de los e-sumarios de las revistas científicas en el mismo momento de publicación

Máxima actualización

Esté informado en todo momento gracias a las alertas y novedades

Promociones exclusivas

Acceda a promociones exclusivas en suscripciones, lanzamientos y cursos acreditados

Crear Mi cuenta
Buscar en
Medicina Clínica
Toda la web
Inicio Medicina Clínica Diferencias de presión arterial entre una toma y la media de 3 tomas medidas au...
Información de la revista
Vol. 149. Núm. 2.Julio 2017
Páginas e7-e12Páginas 49-94
Compartir
Compartir
Descargar PDF
Más opciones de artículo
ePub
Visitas
30
Vol. 149. Núm. 2.Julio 2017
Páginas e7-e12Páginas 49-94
Original breve
DOI: 10.1016/j.medcli.2017.01.013
Diferencias de presión arterial entre una toma y la media de 3 tomas medidas automáticamente. Estudio SPRINT
Blood pressure differences between one automatic measurement and the mean value of 3 automatic measurements. SPRINT trial
Visitas
30
Luis Rodríguez Padiala,
Autor para correspondencia
lrodriguez@sescam.org

Autor para correspondencia.
, Antonio Segura Fragosob, Francisco Javier Alonso Morenoc, Miguel A. Ariasa, Alejandro Villarín Castrod, Gustavo Cristóbal Rodríguez Rocae
a Servicio de Cardiología, Complejo Hospitalario Universitario de Toledo, Toledo, España
b Unidad de Investigación, Instituto de Ciencias de la Salud, Talavera de la Reina, Toledo, España
c Medicina de Familia, Centro de Salud Sillería, Toledo, España
d Medicina de Familia, Unidad docente multiprofesional de Atención Familiar y Comunitaria, Toledo, España
e Medicina de Familia, Centro de Salud de La Puebla de Montalbán, La Puebla de Montalbán, Toledo, España
Este artículo ha recibido
30
Visitas
Información del artículo
Resumen
Texto Completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (1)
Tablas (1)
Tabla 1. Presión arterial sistólica (mmHg) en la primera toma y en el promedio de 3 tomas realizadas mediante dispositivo automático
Resumen
Fundamento y objetivos

Existe discrepancia sobre cómo medir la presión arterial (PA). El objetivo de este trabajo fue estudiar la diferencia entre una determinación y la media de 3 determinaciones automáticas de la PA.

Pacientes y método

Se utilizan 2 poblaciones de pacientes: una muestra poblacional (n=1.337) en la que la medición se realiza por una enfermera en el centro de salud, y una serie consecutiva de pacientes en los que se realiza delante del médico, en la consulta (n=200).

Resultados

Las diferencias halladas entre la primera lectura y el promedio de 3 determinaciones son pequeñas en ambos casos. En la muestra poblacional oscila entre 2,07-3,21mmHg y en los pacientes en los que se determina en presencia del médico, es de 2,71±3,82mmHg en la sistólica, con mínimas diferencia en la PA diastólica.

Conclusiones

En la determinación automática de la PA, existe escasa diferencia entre la primera determinación y el promedio de 3 lecturas.

Palabras clave:
Hipertensión arterial
Medición
Diagnóstico
Abstract
Background and objectives

There are discrepancies regarding how to measure blood pressure (BP). The goal of this study was to determine the differences between one automatic BP measurement and the mean of 3 automatic BP measurements.

Patients and method

Two patient populations were used. A sample population (n=1,337) in which the measurement was performed by a nurse at the health center, and a consecutive series of patients (n=200) who had the measurement performed in front of the doctor in the office.

Results

The differences found between the first reading and the average of 3 determinations were small in both cases. In the population sample, BP levels ranged from 2.07 to 3.21mmHg, and in patients who had their BP levels measured in the presence of doctor, this value ranged from 2.71±3.82mmHg (systolic pressure), with minimal differences in diastolic BP levels.

Conclusions

Little difference was found between the first determination and the average of 3 automatic BP readings.

Keywords:
Arterial hypertension
Measurement
Diagnosis

Artículo

Opciones para acceder a los textos completos de la publicación Medicina Clínica
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Medicina Clínica

Contactar
Teléfono
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas de España
902 88 87 40
Llamadas desde fuera de España
+34 932 418 800
E-mail
Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 22,50 €

Comprar ahora
es en pt
Política de cookies Cookies policy Política de cookies
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here. Utilizamos cookies próprios e de terceiros para melhorar nossos serviços e mostrar publicidade relacionada às suas preferências, analisando seus hábitos de navegação. Se continuar a navegar, consideramos que aceita o seu uso. Você pode alterar a configuração ou obter mais informações aqui.
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos